Siemens

Siemens 6AV7884-5AG20-6GA0 SIMATIC HMI IPC 477C Panel PC

SKU 6AV7884-5AG20-6GA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7884-5AG20-6GA0

  • Country of origin:Germany

  • Product Type: Industrial Panel PC

  • Barcode: 85371098

  • Payment: T/T, Western Union

  • Weight: 15g

  • Dimensions: 64.0 x 64.0 x 42.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7884-5AG20-6GA0 is a SIMATIC HMI IPC 477C, an industrial-grade panel PC designed for demanding visualization and control tasks. This unit is equipped with a 19-inch touch display, an Intel Core 2 Duo 1.2 GHz processor, and 2 GB of DDR3 RAM. For storage, it includes a 50 GB high-endurance SATA solid-state drive (SSD) pre-installed with Windows 7 Ultimate MUI. Connectivity is provided through dual 1 Gbit/s PROFINET (IE) ports and five USB interfaces. This model is part of an optional bundle configuration and is supplied without pre-installed SIMATIC HMI software.

Features

  • 19-inch touch display with a native resolution of 1280 x 1024 pixels.
  • Powered by an Intel Core 2 Duo processor operating at 1.2 GHz.
  • Equipped with 2 GB of DDR3 system memory.
  • Includes a 50 GB high-endurance SATA Solid-State Drive (SSD) for robust data storage.
  • Integrated dual-port PROFINET (IE) interface with 1 Gbit/s speed.
  • Features a total of five USB ports: four on the rear and one on the front for easy access.
  • Comes pre-installed with the Windows 7 Ultimate (MUI) operating system.

Applications

  • Human-Machine Interface (HMI) for complex machinery.
  • Supervisory Control and Data Acquisition (SCADA) systems.
  • Process visualization and control in manufacturing environments.
  • Data logging and analysis at the machine level.
  • Industrial automation gateways and controllers.

Technical Specifications

Category Specification
General Information Manufacturer: Siemens
Model: 6AV7884-5AG20-6GA0
Series: SIMATIC HMI IPC 477C
Product Type: Industrial Panel PC
Product Lifecycle Status: Phase-Out
Processing Unit CPU: Intel Core 2 Duo, 1.2 GHz
Memory: 2 GB RAM, DDR3
Display Type: Touch Display
Size: 19 inch
Resolution: 1280 x 1024 pixels
Storage Type: Solid-State Drive (SSD), High Endurance
Capacity: 50 GB
Interface: SATA
Interfaces Ethernet: 2 x 1 Gbit/s PROFINET (IE)
USB: 4 x Rear Ports, 1 x Front Port
Software Operating System: Windows 7 Ultimate MUI (pre-installed)
Logistics Country of Origin: Germany (Estimate)
Commodity Code: 85371098
ECCN: N
Package Dimensions: 64.0 x 64.0 x 42.0 cm
Shipping Weight: 15.00 kg

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present within industrial control panels. All installation, wiring, and maintenance must be performed by qualified personnel only. Ensure the main power supply to the cabinet is de-energized and locked out (LOTO) before beginning work. Failure to comply can result in severe injury or death.
  1. 1
    De-energize Equipment: Before installation, completely disconnect and lock out all power sources to the control cabinet or mounting location. Verify the absence of voltage using a properly rated test instrument.
  2. 2
    Prepare Panel Cutout: Ensure the mounting cutout in the enclosure door or panel corresponds to the IPC 477C's required dimensions. Deburr all sharp edges to prevent damage to cables and ensure a proper seal.
  3. 3
    Mount the Unit: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a cross-pattern to ensure uniform gasket compression and a proper IP rating.
  4. 4
    Connect Protective Earth (PE): Connect a low-impedance protective earth conductor to the designated PE terminal on the unit's chassis. This is critical for operator safety and noise immunity.
  5. 5
    Connect Power and Interfaces: Connect the DC power supply, PROFINET network cables, and any required USB peripherals. Ensure all connectors are fully seated and secured. Route cables away from high-voltage lines to minimize electrical noise.
  6. 6
    Power-Up and Verification: After closing the cabinet and removing all lock-out/tag-out devices, restore power to the system. Verify that the Panel PC boots correctly into the Windows operating system and that network communication is established.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.