Siemens

Siemens 6AV7893-0BE30-1AB0 SIMATIC HMI IPC677C Panel PC

SKU 6AV7893-0BE30-1AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7893-0BE30-1AB0

  • Country of origin:Germany

  • Product Type: Industrial Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 17450g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7893-0BE30-1AB0 is a SIMATIC HMI IPC677C Panel PC designed for robust and reliable operation in demanding industrial environments. This unit integrates a 15-inch display with a 1024 x 768 resolution and an accessible front-side USB interface. It is equipped with an Intel Core i3-330E processor (2 cores, 4 threads, 2.13 GHz), 4 GB DDR3 memory, and a 250 GB SATA hard disk, along with a DVD+-R+-RW drive for data storage and software installation. The 6AV7893-0BE30-1AB0 features extensive connectivity, including two Gigabit Ethernet ports, four USB 2.0 ports, one serial COM1 port, and an onboard CP 5611-A2-compatible interface for PROFIBUS/MPI. Enhanced reliability features include a built-in RAID controller, 2 MB buffered SRAM, and watchdog, temperature, and fan monitoring. It comes pre-installed with Windows XP Professional SP3 MUI, supporting multiple languages (German, English, French, Spanish, Italian), and is powered by a 110/230 V AC supply unit with NAMUR standard, complete with a European power cable.

Features

  • Integrated 15-inch display with 1024 x 768 resolution
  • Intel Core i3-330E processor (2 cores, 4 threads, 2.13 GHz, HT, VT, 3 MB cache)
  • 4 GB DDR3 1066 DIMM RAM
  • 250 GB SATA Hard Disk Drive and DVD+-R+-RW optical drive
  • Dual Gigabit Ethernet ports (2x 10/100/1000 Mbit/s)
  • Four USB V2.0 ports (including front-side USB-Schnittstelle)
  • One serial (COM1) port
  • PROFIBUS/MPI (CP 5611-A2-compatible) interface
  • Onboard RAID controller and 2 MB buffered SRAM
  • Watchdog, temperature, and fan monitoring functions
  • 110/230 V AC power supply unit with NAMUR standard
  • Pre-installed Windows XP Professional SP3 MUI (de, en, fr, es, it)
  • Two free PCI expansion slots

Applications

The Siemens SIMATIC HMI IPC677C Panel PC is suitable for a wide range of industrial applications requiring integrated control, monitoring, and visualization capabilities. Typical deployments include:
  • Machine control and operation within manufacturing environments
  • Process visualization and data acquisition in industrial plants
  • Human-Machine Interface (HMI) applications for production lines
  • Industrial data logging and archiving solutions
  • Front-end computing for Distributed Control Systems (DCS) and Supervisory Control and Data Acquisition (SCADA) systems

Technical Specifications

Parameter Value
Manufacturer Siemens
Brand Siemens
Range Simatic Panel PC
Subrange IPC677C
Product Type PC panels
PLM Product Phase Phase-Out
Display Size 15 inches
Display Resolution 1024 x 768
Processor Core I3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB cache)
RAM 4 GB DDR3 1066 DIMM
Buffered SRAM 2 MB
Hard Disk Drive 250 GB SATA
Optical Drive DVD+-R+-RW
Ethernet Ports 2x 10/100/1000 Mbit/s
USB Ports 4x USB V2.0
Serial Port 1x (COM1)
PROFIBUS/MPI Interface CP 5611-A2-compatible
Expansion Slots 2x PCI free
Operating System Windows XP Prof. SP3 MUI (de, en, fr, es, it)
Power Supply 110/230 V AC with NAMUR
Shipping Weight 17.45 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Connections / Interfaces

Interface Type Quantity / Description
Ethernet 2x 10/100/1000 Mbit/s ports
USB 4x USB V2.0 ports (including a front-side interface)
Serial 1x COM1 port
PROFIBUS/MPI Onboard CP 5611-A2-compatible interface
Power Supply 110/230 V AC input with NAMUR standard

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and associated equipment is completely de-energized and locked out before beginning any work.
  2. Mounting: Securely mount the Panel PC into a prepared panel cutout, ensuring proper sealing to maintain the specified IP rating of the front panel.
  3. Power Connection: Connect the provided European power cable to the 110/230 V AC power supply unit, adhering to local electrical codes and safety standards. Verify correct voltage and grounding.
  4. Grounding: Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Interface Cabling: Connect Ethernet, USB, and serial communication cables to their respective ports. Ensure proper cable routing to avoid strain and interference.
  6. PROFIBUS/MPI Connection: If utilizing the PROFIBUS/MPI interface, connect the bus cable according to the PROFIBUS standard, ensuring correct termination and shielding.
  7. Environmental Considerations: Ensure the installation environment is within the specified operating temperature and humidity ranges to prevent damage and ensure reliable operation.
  8. Power On: After all connections are verified, re-energize the system and observe for proper startup and functionality.

FAQ

What operating system is pre-installed on this Panel PC?

The unit comes with Windows XP Professional SP3 MUI, supporting multiple languages including German, English, French, Spanish, and Italian.

What are the primary connectivity options for the IPC677C?

It offers two Gigabit Ethernet ports, four USB V2.0 ports, one serial COM1 port, and a PROFIBUS/MPI interface compatible with CP 5611-A2.

Does the Panel PC include any features for data integrity?

Yes, it features an onboard RAID controller and 2 MB of buffered SRAM, along with watchdog, temperature, and fan monitoring for enhanced reliability.

What is the display size and resolution?

The Panel PC is equipped with a 15-inch display offering a resolution of 1024 x 768 pixels.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.