Siemens

Siemens 6AV7894-0AG32-1BA0 SIMATIC IPC677C Panel PC

SKU 6AV7894-0AG32-1BA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7894-0AG32-1BA0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 84714100

  • Payment: T/T, Western Union

  • Weight: 17450g

  • Dimensions: 55 x 45 x 20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This Siemens 6AV7894-0AG32-1BA0 is a SIMATIC HMI IPC677C, a robust industrial panel PC designed for demanding production environments and HMI applications. This model is equipped with a 19-inch touch display with a 1280x1024 resolution, providing clear and direct operator interaction on the plant floor. It is powered by an Intel Core i7-610E processor and 4 GB of DDR3 memory. For data integrity and reliability, the unit features a RAID1 configuration with two 320 GB SATA hard drives. The system is delivered without a pre-installed operating system, offering flexibility for custom software integration. Onboard monitoring for temperature, fan speed, and a watchdog timer ensures operational stability and longevity.

Features

  • 19-inch resistive touch display with 1280x1024 resolution.
  • Intel Core i7-610E processor (2.53 GHz, 2 Cores / 4 Threads).
  • 4 GB DDR3 1066 DIMM system memory.
  • RAID1 configuration with two 320 GB SATA hard drives for data mirroring.
  • Integrated DVD+/-R+/-RW optical drive.
  • Onboard monitoring of temperature, fan, and watchdog timer.
  • Front-panel USB interface for convenient access.
  • Operates on a 24 V DC power supply.

Applications

  • Human Machine Interface (HMI) for process visualization.
  • Supervisory Control and Data Acquisition (SCADA) systems.
  • Machine control and data logging in manufacturing environments.
  • Industrial automation and process control platforms.

Technical Specifications

Specification Value
Brand Siemens
Model Number 6AV7894-0AG32-1BA0
Series SIMATIC HMI IPC677C
Product Type Panel PC
Display 19" Touch, 1280 x 1024 Resolution
Processor Intel Core i7-610E (2C/4T, 2.53GHz, TB, HT, VT, 4 MB Cache)
Memory 4 GB DDR3 1066 DIMM
Storage RAID1 2x 320 GB SATA (2.5") Mirror Disks
Optical Drive DVD+-R+-RW
Expansion Slots 1x PCI, 1x PCIe (x16)
Ethernet 2x 10/100/1000 Mbit/s
Interfaces 4x USB V2.0, 1x Serial (COM1), 1x Front-side USB
Power Supply 24 V DC
System Monitoring Watchdog, Temperature, and Fan Monitoring
Operating System Not included
Product Lifecycle Phase Phase-Out
Shipping Weight 17.45 kg
Commodity Code 84714100
ECCN 5A992
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 55 x 45 x 20 cm

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before installation or maintenance. This equipment contains components sensitive to electrostatic discharge (ESD). Use appropriate ESD protection measures.
  1. 1 Panel Mounting: Ensure the panel cutout dimensions are accurate. Secure the Panel PC into the enclosure using all provided mounting clamps. Tighten clamps evenly to ensure a proper seal against the enclosure surface.
  2. 2 Protective Earth (PE) Connection: Connect the chassis to the main protective earth terminal of the control cabinet. Use a low-impedance connection with a conductor of adequate cross-section to ensure safety and proper noise immunity.
  3. 3 Power Supply Connection: Connect a stable, filtered 24 V DC power source to the designated power input terminals. Verify correct polarity before energizing the unit. Use appropriately sized conductors for the current draw.
  4. 4 I/O and Network Cabling: Connect Ethernet, USB, and serial cables as required. Route signal and communication cables separately from high-voltage power lines to minimize electromagnetic interference (EMI). Use shielded cables for all network connections.
  5. 5 Initial Power-Up: After all connections are verified, restore power to the unit. Proceed with operating system installation and application software configuration as per project requirements.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.