Description
The Siemens
6ES5955-3NC42 is a
SIMATIC S5 power supply unit, specifically designed for use with ZG S5-135U/-155U and EG 183/185U modules. This robust power supply delivers a stable output of 24 V DC and 5 V at 18 A, ensuring consistent and reliable performance for demanding industrial environments. Its design supports continuous operation in various production lines and automated processes where minimal downtime is critical, aligning with Siemens' reputation for durable industrial electronics.
Features
- Designed for SIMATIC S5 automation systems.
- Compatible with ZG S5-135U/-155U and EG 183/185U modules.
- Provides stable 24 V DC and 5 V DC output.
- Delivers up to 18 A output current.
- Robust construction for industrial applications.
Applications
The
6ES5955-3NC42 is suitable for deployment in industrial automation systems requiring a reliable power source for SIMATIC S5 modules, including:
- Production lines
- Automated manufacturing processes
- Industrial control systems
Technical Specifications
| Manufacturer |
Siemens |
| Brand |
Siemens |
| Range |
SIMATIC S5 |
| Subrange |
S5-135/155 |
| Product Type |
Power Supply Module |
| Input Supply Voltage |
24V DC |
| Output Voltage |
24V DC, 5V DC |
| Output Current |
18 A (for 5V output) |
| Product Phase |
Obsolete |
| Predecessor |
6ES5955-3NC41 |
| Package Dimensions (Calculated) |
45.40 x 33.50 x 11.10 cm |
| Shipping Weight |
6.32 kg |
| Commodity Code |
85389091 |
| Export Control Regulations (ECCN) |
N |
Installation Guidelines
Proper installation ensures optimal performance and safety for the
6ES5955-3NC42 power supply module.
-
De-energize System: Before installation or removal, ensure all power to the system rack and connected modules is completely de-energized and locked out.
-
Mounting: Securely mount the power supply unit within the designated rack slot or panel according to the system's mechanical specifications.
-
Wiring: Connect the 24 V DC input power supply to the module's designated terminals, observing correct polarity. Ensure all connections are tight and secure to prevent intermittent operation or arcing.
-
Grounding: Verify proper grounding of the module and the system rack to minimize electrical noise and ensure safety.
-
Ventilation: Ensure adequate clearance around the module for proper airflow and heat dissipation to prevent overheating.
-
Power-Up Sequence: After all connections are verified, re-energize the system following the manufacturer's recommended power-up procedure.