Description

The Siemens 6ES7138-7EC00-0AA0 is a power supply module designed for the SIMATIC ET 200iSP distributed I/O system. This module operates on a wide input voltage range of 120/230 V AC, providing versatile power integration for industrial control panels. It is specifically engineered and certified for safe operation in hazardous areas, holding intrinsic safety certifications for both gas and mining environments. Its robust construction ensures reliable power delivery to connected ET 200iSP I/O modules in critical process automation applications.

Features

  • Designed for the SIMATIC ET 200iSP distributed I/O system
  • Flexible input voltage of 120/230 V AC
  • Certified for hazardous gas atmospheres: Ex db eb [ib] IIC T4 Gb
  • Certified for hazardous mining environments: Ex db eb [ib] I Mb
  • Provides intrinsically safe power for connected I/O modules

Applications

  • Oil and Gas production and refining
  • Chemical and Pharmaceutical processing plants
  • Underground and surface mining operations
  • Any industrial process requiring intrinsically safe distributed I/O

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6ES7138-7EC00-0AA0
Product Series SIMATIC ET 200iSP
Module Type Power Supply Module
Input Voltage 120/230 V AC
Explosion Protection (Gas) Ex db eb [ib] IIC T4 Gb
Explosion Protection (Mining) Ex db eb [ib] I Mb
PLM Product Phase Active
Shipping Weight 2.70 kg
Package Dimensions 6.00 x 13.65 x 19.00 cm
Country of Origin Germany (Estimate)
Harmonized Tariff Code 85044083
ECCN N

Installation Guidelines

CRITICAL WARNING: HAZARDOUS AREA INSTALLATION

Installation, modification, and maintenance of this equipment in hazardous locations must be performed only by qualified personnel trained in accordance with local codes and standards (e.g., IEC 60079-14, NEC Articles 500-505). Failure to comply can result in severe injury or death.

  1. 1 De-energize System: Before installation, completely de-energize the control panel and apply Lockout/Tagout (LOTO) procedures to all incoming power sources. Verify the absence of voltage with a calibrated meter.
  2. 2 Mount Module: Securely mount the 6ES7138-7EC00-0AA0 module onto the designated ET 200iSP terminal block or backplane. Ensure all locking mechanisms are fully engaged to establish a reliable backplane connection.
  3. 3 Connect AC Power: Connect the 120/230 V AC line, neutral, and protective earth (PE) conductors to the designated terminals on the module. Use appropriately sized conductors and ensure terminations are torqued to the manufacturer's specification.
  4. 4 Verify Grounding: Confirm a low-impedance connection from the module's PE terminal to the main system ground bus. Proper grounding is critical for both safety and noise immunity in intrinsically safe circuits.
  5. 5 Final Inspection: Before re-energizing, inspect all wiring for correct polarity, secure connections, and proper dress. Ensure the enclosure integrity is maintained to preserve the Ex rating. Remove LOTO devices and apply power according to site procedures.

FAQ

What is the input voltage for the 6ES7138-7EC00-0AA0 module?

The module accepts a nominal input voltage of 120/230 V AC.

Is this power supply certified for use in hazardous locations?

Yes, it is certified for hazardous areas with ratings of Ex db eb [ib] IIC T4 Gb for gas environments and Ex db eb [ib] I Mb for mining applications.

Which Siemens I/O family is this module compatible with?

This power supply is specifically designed for the Siemens SIMATIC ET 200iSP distributed I/O system.

What is the shipping weight of this power supply module?

The shipping weight for the 6ES7138-7EC00-0AA0 is 2.70 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.