Siemens

Siemens 6ES7141-3BH00-0XA0 ET 200eco Basic Module

SKU 6ES7141-3BH00-0XA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7141-3BH00-0XA0

  • Country of origin:Germany

  • Product Type: Distributed I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 950g

  • Dimensions: 2.5 cm x 5.1 cm x 83.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This Siemens 6ES7141-3BH00-0XA0 is a Basic Module for the ET 200eco distributed I/O system, engineered for reliable signal processing in industrial environments. As a compact and durable component, it simplifies plant configuration by minimizing wiring complexity and reducing susceptibility to electromagnetic interference. The module facilitates straightforward commissioning and provides advanced diagnostic functions for stable, long-term operation. Communication is handled via the PROFIBUS DP protocol, ensuring fast and accurate data exchange between the controller and field devices.

Features

  • Integral component of the SIMATIC ET 200eco distributed I/O family.
  • Enables communication over the PROFIBUS DP fieldbus network.
  • Designed for simplified wiring and flexible installation.
  • Features advanced diagnostic capabilities for system monitoring.
  • Compact and robust construction suitable for field applications.

Applications

  • Distributed control systems in factory automation
  • Machine building and OEM equipment
  • Process control and monitoring
  • Material handling and conveyor systems

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7141-3BH00-0XA0
Product Series SIMATIC ET 200eco
Module Type Basic Module
Condition Brand New
Communication Protocol PROFIBUS DP
Lifecycle Status Active
Shipping Weight 0.95 kg
Package Dimensions (Calculated) 2.5 cm x 5.1 cm x 83.8 cm
Country of Origin Germany
HS Code 8537101190

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Installation must be performed by qualified personnel only. Failure to de-energize the system and follow Lockout/Tagout (LOTO) procedures before installation can result in severe injury or death.
  1. 1
    System De-energization: Before starting any work, completely disconnect power to the control panel and all related machinery. Verify zero energy state using a calibrated voltmeter. Apply appropriate LOTO devices.
  2. 2
    Module Mounting: Securely mount the ET 200eco module directly to a clean, flat, and conductive surface on the machine or panel. Ensure all mounting screws are tightened to the manufacturer's specified torque to guarantee a solid mechanical and grounding connection.
  3. 3
    PROFIBUS DP Connection: Use approved PROFIBUS DP cables. Ensure proper termination at both ends of the bus segment. Connect the cable shield to the functional earth (FE) terminal at one point to prevent ground loops.
  4. 4
    Power and I/O Wiring: Connect the 24V DC power supply and I/O field device wiring to the appropriate terminals. Ensure correct polarity. Use ferrules on stranded wires for secure connections and route cables to minimize electrical noise interference.
  5. 5
    System Commissioning: After all connections are verified, remove LOTO devices and restore power. Configure the module in the PLC programming software, set the correct PROFIBUS address, and test all I/O points for correct functionality.

FAQ

What system is the 6ES7141-3BH00-0XA0 designed for?

This module is part of the Siemens SIMATIC ET 200eco distributed I/O system, intended for machine-level installation.

What communication protocol does this module use?

It communicates using the PROFIBUS DP protocol for deterministic data exchange with a master PLC or controller.

Is this a new or refurbished part?

This is a brand new, factory-sealed module. It is not used or refurbished.

What is the primary function of this Basic Module?

It serves as a base for signal processing within the ET 200eco system, simplifying wiring, enabling diagnostics, and connecting field devices to the PROFIBUS network.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.