Siemens

Siemens 6ES7647-6CB00-0BA0 SIMATIC IPC627C Box PC

SKU 6ES7647-6CB00-0BA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-6CB00-0BA0

  • Country of origin:Germany

  • Product Type: Industrial Box PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 7050g

  • Dimensions: 45.0 x 47.5 x 27.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7647-6CB00-0BA0 is a SIMATIC IPC627C series Box PC designed for robust industrial applications. This unit is configured with an Intel Celeron P4505 processor, 1 GB of DDR3 RAM, and a 250 GB SATA hard drive. It provides extensive connectivity through dual Gigabit Ethernet ports, a PROFIBUS/MPI interface, and multiple USB 2.0 ports. The system includes an integrated 110/230V AC industrial power supply and comes pre-installed with the Windows XP Professional SP3 operating system, making it a comprehensive platform for control, visualization, and data acquisition tasks.

Features

  • Processor: Intel Celeron P4505 (2 Cores, 2 Threads, 1.86 GHz)
  • Memory: 1 GB DDR3 1066 DIMM and 2 MB buffered SRAM
  • Storage: 250 GB SATA Hard Disk Drive (HDD) and a DVD+/-RW optical drive
  • Connectivity: Dual 10/100/1000 Mbit/s Ethernet ports
  • Fieldbus Interface: Integrated PROFIBUS/MPI (CP 5611-A2 compatible)
  • Expansion: Two free PCI slots for additional hardware
  • Power Supply: 110/230V AC industrial power supply with NAMUR compliance
  • System Monitoring: Integrated watchdog timer, temperature, and fan monitoring
  • Operating System: Pre-installed Windows XP Professional SP3 (MUI)

Applications

  • Machine-level data processing and control
  • Process visualization and HMI server tasks
  • Industrial data acquisition and logging
  • Gateway applications between IT and OT networks
  • Automation cells requiring legacy OS support

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC IPC627C
Model Number 6ES7647-6CB00-0BA0
Product Type Box PC
Product Lifecycle Status Phase-Out
Processor Intel Celeron P4505 (2 Cores, 2 Threads, 1.86 GHz, 2 MB Cache, VT)
System Memory (RAM) 1 GB DDR3 1066 DIMM
Buffered Memory 2 MB Buffered SRAM
Hard Drive 250 GB HDD SATA
Optical Drive DVD +/-RW
Storage Controller Onboard RAID Controller
Removable Media CompactFlash Drive Slot (Front)
Graphics Onboard HD Graphics
Ethernet Ports 2 x 10/100/1000 Mbit/s RJ45
USB Ports 4 x USB 2.0 (High Current)
Serial Port 1 x COM1
Fieldbus Port PROFIBUS/MPI (CP 5611-A2-compatible)
Expansion Slots 2 x PCI (free)
Power Supply 110/230V AC Industrial Power Supply Unit with NAMUR
Operating System Windows XP Professional SP3 MUI (DE, EN, FR, ES, IT)
Shipping Weight 7.05 kg
Package Dimensions (Calculated) 45.0 x 47.5 x 27.0 cm
Country of Origin (Estimate) Germany
Commodity Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. All installation, wiring, and maintenance must be performed by qualified personnel only. Ensure the unit is de-energized and proper Lockout/Tagout (LOTO) procedures are followed before accessing any terminals or internal components.
  1. 1 Site Preparation: Select a mounting location within an industrial enclosure that provides adequate ventilation and protection from moisture, corrosive agents, and excessive vibration. Ensure ambient temperature remains within the device's operating range.
  2. 2 Mounting: Securely fasten the Box PC chassis to the mounting panel using all provided mounting points. Verify the unit is level and stable.
  3. 3 Grounding: Connect the chassis grounding terminal to the main panel's protective earth (PE) busbar using a low-impedance conductor. A proper ground connection is critical for safety and noise immunity.
  4. 4 I/O Connections: Connect all required peripheral and network cables, including Ethernet, PROFIBUS, USB, and serial devices. Use shielded cables for communication lines and ensure shields are properly terminated to ground at one end.
  5. 5 Power Connection: Connect the provided AC power cable to the unit's power supply inlet and to a stable, correctly rated AC power source. Ensure the source voltage matches the 110/230V AC rating.
  6. 6 System Startup: After verifying all connections, remove LOTO and apply power to the unit. Observe the boot sequence to ensure the operating system loads correctly and check for any hardware fault indicators.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.