Siemens

Siemens 6ES7675-1DK30-0DB0 SIMATIC IPC427C Microbox PC

SKU 6ES7675-1DK30-0DB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7675-1DK30-0DB0

  • Country of origin:Germany

  • Product Type: Industrial PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 2620g

  • Dimensions: 32.2 x 28.1 x 13.1 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This product is a Siemens 6ES7675-1DK30-0DB0, a compact SIMATIC IPC427C Microbox PC bundle designed for demanding automation tasks. It is equipped with an Intel Core 2 Duo 1.2 GHz processor with an 800 MHz Front Side Bus (FSB). The system includes 2 GB of DDR3 1066 SODIMM RAM and a 4 GB CompactFlash card for storage, accessible to the user. This specific bundle comes pre-installed with Windows Embedded Standard and WinAC RTX software, providing a ready-to-deploy platform for PC-based control. Connectivity is handled by two 1 Gbit Industrial Ethernet ports and one PROFIBUS DP interface.

Features

  • Processor: Intel Core 2 Duo running at 1.2 GHz
  • Memory: 2 GB DDR3 1066 SODIMM
  • Storage: 4 GB accessible CompactFlash card
  • Industrial Networking: Dual 1 Gbit Industrial Ethernet (IE) ports
  • Fieldbus Connectivity: Integrated PROFIBUS DP (PB DP) port
  • Pre-installed Software: Windows Embedded Standard and WinAC RTX
  • Compact, fanless design suitable for control cabinet mounting

Applications

  • PC-based automation and process control
  • Data acquisition, logging, and gateway functions
  • Human-Machine Interface (HMI) and SCADA applications
  • Motion control and robotics
  • Embedded machine control in manufacturing environments

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC IPC427C
Product Type Microbox PC
Processor Intel Core 2 Duo, 1.2 GHz
Front Side Bus (FSB) 800 MHz
Memory 2 GB DDR3 1066, SODIMM
Storage 4 GB CompactFlash
Ethernet Interfaces 2 x 1 Gbit Industrial Ethernet
Fieldbus Interface 1 x PROFIBUS DP
Pre-installed Software Windows Embedded Standard, WinAC RTX
Product Lifecycle Status Obsolete
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 32.20 x 28.10 x 13.10 cm
Shipping Weight 2.62 kg
Commodity Code 85371091
ECCN 5D002

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources before installation or maintenance. This device operates with hazardous voltages. Installation must be performed by qualified personnel only, adhering to all local electrical codes and safety regulations. Failure to comply can result in severe injury, death, or equipment damage.
  1. 1 Mounting: Securely mount the IPC427C unit inside a suitable enclosure that provides protection against environmental factors. Ensure adequate ventilation and clearance around the unit for heat dissipation.
  2. 2 Grounding: Connect the chassis ground terminal to the main protective earth (PE) busbar of the control cabinet using a low-impedance conductor. Proper grounding is essential for noise immunity and safety.
  3. 3 Power Connection: Connect a stable, filtered 24V DC power supply to the designated power input terminals. Verify the polarity and voltage are correct before applying power.
  4. 4 Network Cabling: Connect shielded Ethernet cables to the RJ45 ports for network communication. Connect the PROFIBUS DP cable to its respective D-sub connector. Ensure all communication cables are routed away from high-voltage power lines to prevent interference.
  5. 5 Initial Power-Up: After all connections are verified, apply power to the unit. Monitor the status LEDs to confirm a successful boot sequence and initialization of the operating system.

FAQ

What processor is installed in the 6ES7675-1DK30-0DB0?

This unit is equipped with an Intel Core 2 Duo processor operating at 1.2 GHz with an 800 MHz Front Side Bus.

What type and size of storage is included?

The IPC comes with a 4 GB CompactFlash (CF) card for the operating system and user data. It does not include an internal hard disk drive or solid-state drive.

What software is pre-installed on this device?

This bundle is delivered with Windows Embedded Standard and Siemens WinAC RTX software pre-installed on the CompactFlash card.

What are the primary communication interfaces on this Microbox PC?

It features two 1 Gbit Industrial Ethernet ports for standard networking and one PROFIBUS DP port for fieldbus communication with PLCs and I/O devices.

Is this product still in active production by Siemens?

No, the SIMATIC IPC427C series, including this model, is listed with an 'Obsolete' product lifecycle status. It is available as a spare part.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...