Siemens

Siemens 6ES7675-1DK30-2AL0 SIMATIC IPC427C Microbox PC Bundle

SKU 6ES7675-1DK30-2AL0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7675-1DK30-2AL0

  • Country of origin:Germany

  • Product Type: Industrial PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 3400g

  • Dimensions: 18.5 cm x 18.5 cm x 15.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6ES7675-1DK30-2AL0, a pre-configured SIMATIC IPC427C Microbox PC bundle designed for demanding PC-based automation tasks. The unit is equipped with an Intel Core 2 Duo 1.2 GHz processor, 2 GB of DDR3 RAM, and a 50 GB high-endurance SATA Solid-State Drive (SSD) for reliable, fanless operation. It comes pre-installed with a comprehensive software package including Windows Embedded Standard 2009, the WinAC RTX 2010 software controller, and WinCC flexible 2008 RT for HMI applications. Connectivity is provided through one PROFIBUS DP port and two 1 Gbit/s Industrial Ethernet interfaces, making it suitable for integrated control and visualization solutions.

Features

  • Processor: Intel Core 2 Duo at 1.2 GHz with 800 MHz FSB
  • Memory: 2 GB DDR3 1066 SODIMM
  • Storage: 50 GB High-Endurance SATA Solid-State Drive (SSD)
  • Operating System: Windows Embedded Standard 2009 (Pre-installed)
  • Software Controller: WinAC RTX 2010
  • HMI Runtime: WinCC flexible 2008 RT (512 PowerTags)
  • Industrial Communication: 1x PROFIBUS DP, 2x Gigabit Industrial Ethernet
  • Compact, fanless Microbox design

Applications

  • PC-based machine control and automation
  • Human-Machine Interface (HMI) and SCADA applications
  • Data acquisition, logging, and processing at the machine level
  • Gateway and communication tasks in industrial networks
  • Process control and visualization in manufacturing

Technical Specifications

Category Specification
General
Part Number 6ES7675-1DK30-2AL0
Base Model SIMATIC IPC427C Microbox PC
Product Lifecycle Status Phase-Out
Hardware
Processor Intel Core 2 Duo, 1.2 GHz
Front Side Bus (FSB) 800 MHz
Memory 2 GB DDR3 1066, SODIMM
Storage 50 GB Solid-State Drive (SATA, High Endurance)
Software
Operating System Windows Embedded Standard 2009
Control Software WinAC RTX 2010
HMI Runtime WinCC flexible 2008 RT (512 PowerTags)
Interfaces
PROFIBUS 1x PROFIBUS DP
Ethernet 2x Industrial Ethernet (1 Gbit/s)
Logistics
Shipping Weight 3.40 kg
Package Dimensions (Calculated) 18.5 cm x 18.5 cm x 15.0 cm
Country of Origin (Estimate) Germany
Commodity Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE

Installation must be performed by qualified personnel only. Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before accessing or installing this equipment. This device contains components sensitive to electrostatic discharge (ESD). Use proper ESD protection, including wrist straps and grounded mats, during handling and installation.

  1. 1 De-energize System: Before installation, ensure the control cabinet and all related power sources are completely de-energized, locked out, and tagged out to prevent accidental activation.
  2. 2 Mount the IPC: Securely mount the Microbox PC onto a standard DIN rail or a flat panel surface inside the control cabinet. Ensure adequate ventilation space around the unit as specified by the manufacturer for proper heat dissipation.
  3. 3 Establish Ground Connection: Connect the chassis grounding terminal to the main protective earth (PE) busbar of the control cabinet using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.
  4. 4 Connect Communication Cables: Connect the PROFIBUS DP and Industrial Ethernet cables. Use appropriately shielded cables and ensure proper shield termination at one end to minimize electromagnetic interference (EMI). Route communication cables separately from high-voltage power lines.
  5. 5 Connect Power Supply: Connect the 24V DC power supply to the designated power input terminals. Verify the polarity is correct before applying power. Use appropriately sized wiring for the load.
  6. 6 System Power-Up: After verifying all connections, remove the lockout/tagout and re-energize the control cabinet. Monitor the IPC for correct boot-up sequence and status indicator activity.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.