Siemens

Siemens 6ES7710-1AA31-0FB1 SIMATIC Field PG Programming Device

SKU 6ES7710-1AA31-0FB1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7710-1AA31-0FB1

  • Country of origin:Germany

  • Product Type: Field PG

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 29.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7710-1AA31-0FB1 is a SIMATIC Field PG, a ruggedized portable computer designed for commissioning, servicing, and maintaining industrial automation systems. This unit is equipped with a Pentium III 700 MHz processor, 256 MB of SDRAM, and a 20 GB EIDE hard drive. It comes pre-installed with Windows 2000 MUI and STEP software (version 08/2001), providing a ready-to-use platform for engineering tasks directly on the plant floor. The device includes both a CD-ROM drive and a SuperDisk LS 240 drive for flexible data transfer and software installation.

Features

  • Processor: Intel Pentium III operating at 700 MHz.
  • Memory: 256 MB SDRAM installed.
  • Storage: 20 GB internal hard disk drive with EIDE interface.
  • Optical Media: Integrated CD-ROM drive.
  • Removable Media: SuperDisk LS 240 drive.
  • Operating System: Windows 2000 Multi-language User Interface (MUI).
  • Pre-installed Software: Includes STEP-Software package (version dated 08/2001).
  • Power Cable: Supplied with a power cable compatible with outlets in Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, and Finland.

Applications

  • Commissioning and startup of PLC and HMI systems.
  • On-site diagnostics and troubleshooting of industrial control panels.
  • Program development, modification, and backup for SIMATIC controllers.
  • Field service and maintenance of automated machinery and process plants.

Technical Specifications

Specification Value
Brand Siemens
Product Range SIMATIC Field PG
Processor Pentium III, 700 MHz
L2 Cache 256 KB
Memory (RAM) 256 MB SDRAM (1x256 MB)
Hard Drive 20 GB EIDE
Optical Drive CD-ROM Drive
Removable Media Drive SuperDisk LS 240 Drive
Operating System Windows 2000 MUI GEFSI
Product Lifecycle Status Phase-Out
Shipping Weight 4.00 kg
Package Dimensions (Calculated) 29.0 x 25.0 x 25.0 cm
Commodity Code 84713000
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: This equipment is intended for use by qualified personnel only. Failure to observe this precaution could result in severe injury or damage to equipment. Always de-energize and lock out/tag out all power sources before connecting or disconnecting any cables.
  1. 1 Place the Field PG on a stable, level surface with adequate ventilation to prevent overheating. Avoid areas with high levels of dust, moisture, or vibration.
  2. 2 Connect the supplied power cable to the Field PG and a properly grounded AC power outlet. Verify the mains voltage matches the rating specified for the device.
  3. 3 Power on the device and allow the Windows 2000 operating system to fully load before launching any engineering software or connecting to industrial networks.
  4. 4 When connecting to a PLC or other automation components, use the appropriate Siemens-specified programming cables (e.g., MPI, PROFIBUS). Ensure all connections are secure before attempting communication.
  5. 5 After use, perform a proper shutdown of the operating system before disconnecting power. Store the Field PG in a clean, dry environment to protect it from industrial contaminants.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.