Siemens

Siemens 6ES7710-5CA55-4FB4 SIMATIC Field PG Pentium III

SKU 6ES7710-5CA55-4FB4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7710-5CA55-4FB4

  • Country of origin:Germany

  • Product Type: Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 29.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7710-5CA55-4FB4 is a SIMATIC Field PG, a robust programming device designed for industrial automation environments. This unit features a Pentium III 1 GHz processor, 256 KB L2 cache, and 512 MB SDRAM (configured as 2x256 MB modules). It includes a 40 GByte EIDE HDD, a DVD-ROM / CD-RW drive, and a 1.44 MB floppy disk drive for comprehensive data handling. The device comes pre-installed with Windows 2000 MUI GEFSI and essential Siemens programming software, including STEP 7, STEP 5, and STEP 7 MicroWIN (installed December 2002), making it suitable for programming and diagnostics of various Siemens PLC systems.

Features

  • Integrated Pentium III 1 GHz Processor
  • 256 KB Second Level Cache
  • 512 MB RAM (2x256 MB SDRAM)
  • 40 GByte EIDE Hard Disk Drive
  • DVD-ROM / CD-RW Optical Drive
  • 1.44 MB Floppy Disk Drive
  • Pre-installed Windows 2000 MUI GEFSI Operating System
  • Includes STEP 7, STEP 5, and STEP 7 MicroWIN Software
  • Supplied with power cable for specific European regions

Applications

The SIMATIC Field PG 6ES7710-5CA55-4FB4 is typically deployed in industrial settings for:

  • Programming and configuration of Siemens SIMATIC S5 and S7 PLCs.
  • On-site diagnostics and troubleshooting of automation systems.
  • Data backup and restoration for industrial controllers.
  • Software updates and maintenance for legacy Siemens automation infrastructure.
  • Field engineering tasks requiring a dedicated and robust programming platform.

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG
Type of Product Pentium 3 Programming Device
Processor Pentium III 1 GHz
L2 Cache 256 KB
RAM 512 MB (2x256 MB SDRAM)
Hard Disk Drive 40 GByte HDD EIDE
Optical Drive DVD-ROM / CD-RW Drive
Floppy Disk Drive 1.44 MB
Operating System Windows 2000 MUI GEFSI
Pre-installed Software STEP 7, STEP 5, STEP 7 MicroWIN (Installed 12/2002)
Power Cable Included For Germany, France, Netherlands, Spain, Belgium, Austria, Sweden, Finland
PLM Product Phase Obsolete
Package Dimensions (Calculated) 29.00 x 25.00 x 25.00 cm
Shipping Weight 4.00 kg
Commodity Code 84713000

Installation Guidelines

  1. Power Connection: Connect the appropriate power cable (included for specified regions) to the Field PG and a compatible power outlet. Ensure the power source meets the device's electrical requirements.
  2. Initial Boot-up: Power on the Field PG. The Windows 2000 operating system should boot automatically.
  3. Software Access: The programming software (STEP 7, STEP 5, STEP 7 MicroWIN) is pre-installed. Access these applications via the Start Menu or desktop shortcuts.
  4. Peripheral Connections: Connect any necessary peripherals such as external monitors, keyboards, mice, or communication cables (e.g., MPI/DP cables for PLC connection) to the available ports.
  5. Data Transfer: Utilize the DVD-ROM/CD-RW drive, floppy disk drive, or USB ports (if available and supported by the OS) for transferring project files or data.
  6. Safety Precautions: Always ensure the Field PG is placed on a stable surface. Avoid exposing the device to excessive dust, moisture, or extreme temperatures. De-energize connected industrial equipment before establishing communication links to prevent accidental operations.

FAQ

What is the primary function of the Siemens 6ES7710-5CA55-4FB4?

This device serves as a SIMATIC Field PG, a portable programming device for configuring, diagnosing, and maintaining Siemens SIMATIC S5 and S7 PLC systems in industrial environments.

What operating system and key software are pre-installed on this Field PG?

The Field PG comes with Windows 2000 MUI GEFSI and includes pre-installed Siemens programming software such as STEP 7, STEP 5, and STEP 7 MicroWIN.

What are the main storage components of this programming device?

It features a 40 GByte EIDE hard disk drive, a DVD-ROM / CD-RW drive, and a 1.44 MB floppy disk drive for data storage and transfer.

Is this Field PG still actively supported by Siemens?

According to the product phase, this model is classified as obsolete.

What type of processor and RAM does the 6ES7710-5CA55-4FB4 utilize?

It is equipped with a Pentium III 1 GHz processor and 512 MB of SDRAM (2x256 MB modules).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...

Commissioning a Micro800 PLC in FactoryTalk Design Workbench

A practical Micro800 commissioning workflow covering hardware checks, USB and Ethernet discovery, safe ladder testing, download risks, fault isolation, and project recovery in FactoryTalk Design...

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.