Siemens

Siemens 6ES7715-1BB20-0BA1 SIMATIC Field PG M3 Premium Programming Device

SKU 6ES7715-1BB20-0BA1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7715-1BB20-0BA1

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7715-1BB20-0BA1 is a SIMATIC Field PG M3 Premium industrial programming device designed for mobile use in automation environments. This unit features a Core i5-520M processor running at 2.4GHz, a 500GB S-ATA Hard Disk Drive (HDD), and a DL Multistandard DVD RW drive. It is equipped with a 15.6-inch Full HD display (1920 x 1080) for clear visualization. The device includes a QWERTY and German keyboard layout and comes with a power cable suitable for various European regions (GE, FR, NL, ES, BE, AT, SE, FI, C). Notably, this specific configuration does not include an S5-interface or an S5-EPROMmer.

Features

  • Core i5-520M Processor, 2.4GHz
  • 500GB S-ATA Hard Disk Drive (HDD)
  • DL Multistandard DVD RW Optical Drive
  • 15.6-inch Full HD Display (1920 x 1080)
  • QWERTY and German Keyboard Layout
  • Includes power cable for GE, FR, NL, ES, BE, AT, SE, FI, C regions
  • No S5-interface or S5-EPROMmer

Applications

The SIMATIC Field PG M3 Premium is typically deployed for:
  • On-site commissioning and maintenance of SIMATIC automation systems.
  • Programming and configuration of Siemens PLCs and HMI devices.
  • Diagnostics and troubleshooting in industrial control environments.
  • Mobile engineering tasks requiring robust, portable hardware.

Technical Specifications

Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG M3
Product Type Premium Programming Device
Product Phase Obsolete
Processor Core i5-520M, 2.4GHz
Storage 500GB S-ATA HDD
Optical Drive DL Multistandard DVD RW
Display 15.6'' Full HD (1920 x 1080)
Keyboard Layout QWERTY and German
S5 Interface Not included
S5 EPROMmer Not included
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) 5A992

Installation Guidelines

As a portable industrial programming device, the Siemens 6ES7715-1BB20-0BA1 requires careful handling and proper power connection:
  1. Power Connection: Connect the provided power cable to a suitable mains outlet. Ensure the power supply matches the device's requirements and the specific regional power cable supplied (GE, FR, NL, ES, BE, AT, SE, FI, C).
  2. Environmental Considerations: Operate the device within typical industrial temperature and humidity ranges. Avoid exposure to excessive dust, moisture, or direct sunlight.
  3. Software Installation: Install the necessary SIMATIC engineering software (e.g., TIA Portal, STEP 7) as required for your specific automation tasks.
  4. Peripheral Connections: Connect any required external devices (e.g., USB, Ethernet) for communication with PLCs or other automation components.
  5. Safety: Always ensure the device is placed on a stable surface during operation. Disconnect power before cleaning or extended storage.

FAQ

What is the primary purpose of the Siemens 6ES7715-1BB20-0BA1?

It is a SIMATIC Field PG M3 Premium industrial programming device used for mobile programming, configuration, and diagnostics of Siemens automation systems.

What are the key hardware specifications of this Field PG?

It features a Core i5-520M 2.4GHz processor, a 500GB S-ATA HDD, a DL Multistandard DVD RW drive, and a 15.6-inch Full HD (1920 x 1080) display.

Does this specific model include an S5 interface?

No, the 6ES7715-1BB20-0BA1 configuration explicitly states 'W/O S5-INTERFACE' and 'W/O S5-EPROMMER'.

What is the display resolution of the Field PG M3?

The device is equipped with a 15.6-inch display offering Full HD resolution (1920 x 1080).

What is the product phase of this Siemens Field PG?

According to the manufacturer's information, this product model is currently in the 'Obsolete' phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...