Siemens 6ES7715-1BB22-0AA0 SIMATIC Field PG M3 Industrial Programming Device

SKU 6ES7715-1BB22-0AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7715-1BB22-0AA0

  • Country of origin:Germany

  • Product Type: Industrial Programming Devices

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7715-1BB22-0AA0 is a SIMATIC Field PG M3 Premium, an industrial notebook engineered for programming, commissioning, and maintaining automation systems in demanding factory environments. This device is equipped with an Intel Core i5-520M processor, 3 GB of DDR3 RAM, and a 500 GB SATA HDD for reliable performance and data storage. It features a high-resolution 15.6-inch Full HD display, ideal for complex process visualization and software development. This specific configuration is supplied without the legacy S5 interface or S5-EPROMMER, targeting modern automation infrastructures. The unit includes pre-installed software trial licenses and power cables for use in the USA and Japan.

Features

  • Processor: Intel Core i5-520M running at 2.4 GHz.
  • Memory: 3 GB DDR3 RAM (configured as 1x 1 GB and 1x 2 GB modules).
  • Storage: 500 GB SATA Hard Disk Drive (HDD).
  • Display: 15.6-inch Full HD screen with 1920 x 1080 resolution.
  • Optical Drive: DL Multi-Standard DVD RW for flexible data transfer.
  • Keyboard: QWERTY layout with German character set.
  • Operating System: Windows XP Professional (English MUI) with German, French, Spanish, and Italian images.
  • Included Software: Trial licenses for STEP 7 Professional and WinCC flexible Advanced (Version 04/2010).
  • Approvals: Certified for use in the USA (FCC) and Canada (IC).

Applications

  • PLC and HMI programming and configuration.
  • Commissioning and startup of industrial machinery.
  • On-site diagnostics and troubleshooting of automation systems.
  • System maintenance and software updates in the field.
  • Data logging and analysis directly on the plant floor.

Technical Specifications

Specification Value
Brand Siemens
Model 6ES7715-1BB22-0AA0
Series SIMATIC Field PG M3 Premium
Processor Intel Core i5-520M, 2.4 GHz
Memory (RAM) 3 GB DDR3
Storage 500 GB SATA HDD
Display 15.6-inch Full HD (1920 x 1080)
Operating System Windows XP Professional English MUI
S5 Interface Not included
S5-EPROMMER Not included
Approvals FCC (USA), IC (Canada)
PLM Status Obsolete
Shipping Weight 3.50 kg
Package Dimensions (Source) 39.50 x 30.00 x 17.00 cm
Country of Origin Germany (Estimate)
Manufacturer Siemens

Installation and Handling Guidelines

CRITICAL WARNING: This device interfaces with industrial control systems. Improper connection or use can result in equipment damage, production loss, or serious injury. All work must be performed by qualified personnel in accordance with local safety regulations and site-specific procedures.
  1. 1 Upon receipt, visually inspect the Field PG for any signs of physical damage incurred during transit. Do not power on a damaged unit.
  2. 2 Select the correct power supply cable (USA or Japan provided) and connect it to a stable, grounded AC power source. Verify the integrity of the power supply and cabling before connection.
  3. 3 Power on the device and allow the operating system to boot completely. Verify basic functionality before proceeding to connect to any industrial network or controller.
  4. 4 When connecting to a plant network or directly to a PLC, use high-quality, properly shielded communication cables (e.g., PROFIBUS, PROFINET). Ensure network settings are correctly configured to avoid IP conflicts or communication errors.
  5. 5 Operate the Field PG on a stable, level surface. Keep ventilation openings clear to prevent overheating. Avoid exposure to excessive dust, moisture, vibration, or extreme temperatures common in industrial settings.
  6. 6 Always follow plant-specific Lockout-Tagout (LOTO) procedures before connecting to or disconnecting from energized equipment. Confirm the system is in a safe state before downloading new configurations or forcing I/O.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.