1 of 1

Siemens 6ES7716-1BB03-0AC1 SIMATIC Field PG M4 Premium Programming Device

Siemens 6ES7716-1BB03-0AC1 SIMATIC Field PG M4 Premium Programming Device

Only 4 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6ES7716-1BB03-0AC1

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 85371099

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 50 cm x 40 cm x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Siemens 6ES7716-1BB03-0AC1 SIMATIC Field PG M4 Premium is a robust industrial programming device designed for demanding automation engineering tasks. This unit features a Core I5-3320M processor, 4 GB of RAM, and a 1 TB SATA hard disk drive, providing ample performance and storage for various software applications. It includes an integrated DVD RW optical drive and HD Graphics 4000. Specifically equipped with an S5 interface and S5-EPROMMER, along with an S5-AG cable and EPROM adapter, it supports legacy Siemens S5 systems. The device comes with a 15.6-inch HD READY display (1366x768), a QWERTY (German) keyboard, and a power supply cable for the USA. It is pre-installed with Windows XP Professional SP3 English MUI (32-bit, multi-language support). Software licenses for STEP 7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5 are included, along with an MPI cable for connectivity.

Features

  • Intel Core I5-3320M Processor (2.6 GHz, up to 3.3 GHz with Turbo Boost)
  • 1 x 4 GB RAM
  • 1 TB SATA Hard Disk Drive
  • Integrated DVD RW Optical Drive
  • HD Graphics 4000
  • 15.6-inch HD READY Display (1366x768)
  • S5 Interface with S5-EPROMMER and EPROM Adapter
  • Pre-installed Windows XP Professional SP3 (32-bit, English MUI)
  • Includes Licenses for STEP 7 Prof combo, WinCC Advanced combo, STEP 7 Micro/WIN V4.0, STEP 5
  • Supplied with S5-AG Cable, MPI Cable, and USA Power Supply Cable

Applications

  • PLC Programming and Configuration for Siemens SIMATIC S5 and S7 systems
  • HMI/SCADA System Development and Commissioning
  • Industrial Automation System Diagnostics and Troubleshooting
  • On-site Engineering and Maintenance for Production Facilities
  • Data Archiving and Firmware Updates for Automation Components

Technical Specifications

Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG M4
Product Type Premium Programming Device
PLM Product Phase Phase-Out
Processor Intel Core I5-3320M (3 MB cache, 2.6 GHz, up to 3.3 GHz with Turbo Boost)
RAM 1 x 4 GB
Storage 1 TB HDD SATA
Optical Drive DVD RW
Graphics HD Graphic 4000
Display Size 15.6 inches
Display Resolution HD READY (1366x768)
Keyboard Layout QWERTY (German)
Operating System Windows XP Professional SP3 English MUI, 32 bit (de/en/fr/es/it)
Included Software Licenses STEP 7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5
General Software Version V12.0.0.0
Included Accessories S5-AG cable, EPROM adapter, MPI cable, Power supply cable for USA
Shipping Weight 4.00 kg
Commodity Code 85371099
Export Control Regulations (ECCN) N
Package Dimensions (Calculated) 50 cm x 40 cm x 15 cm

Installation Guidelines

  1. Unpacking and Inspection: Carefully remove the Field PG from its packaging. Inspect for any visible damage that may have occurred during transit.
  2. Power Connection: Connect the provided power supply cable to the Field PG and a suitable power outlet. Ensure the outlet meets the required voltage specifications for the device.
  3. Initial Power-Up: Power on the Field PG. Allow the operating system to load completely.
  4. Software Verification: Verify that the pre-installed Windows XP Professional and the included Siemens engineering software licenses (STEP 7, WinCC, STEP 5, etc.) are present and functional.
  5. Peripheral Connections: Connect any necessary external peripherals such as a mouse, external monitor, or industrial communication cables (S5-AG, MPI) as required for your programming task.
  6. Environmental Considerations: Operate the Field PG within a clean, dry environment, avoiding excessive dust, moisture, and extreme temperatures to ensure optimal performance and longevity.
  7. Data Backup: Regularly back up important project data and configurations to an external storage device to prevent data loss.

What operating system is pre-installed on the Field PG M4?

The Siemens 6ES7716-1BB03-0AC1 comes with Windows XP Professional SP3 English MUI, 32-bit, with multi-language support (de/en/fr/es/it).

Does this Field PG support programming for Siemens S5 PLCs?

Yes, it includes an S5 interface, S5-EPROMMER, S5-AG cable, EPROM adapter, and a license for STEP 5 software, enabling support for S5 systems.

What display resolution does the Field PG M4 offer?

It features a 15.6-inch HD READY display with a resolution of 1366x768 pixels.

Are modern Siemens software versions pre-installed?

No, the description explicitly states that STEP 7 Prof V13 and WinCC Advanced V13 are not pre-installed, though licenses for these versions (and older compatible versions) are included.

What is the primary storage capacity of this device?

The device is equipped with a 1 TB SATA Hard Disk Drive.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...