Description

The Siemens 6ES7716-2CA14-0CB4 is a SIMATIC Field PG M4 Premium plus industrial programming device designed for automation engineering tasks. This robust portable computer features a Core I7-35X0M processor (4M cache, 2.9 GHz, up to 3.6 GHz with Turbo Boost technology), 16 GB of RAM (2x 8 GB), and a 300 GB SATA Solid State Drive for reliable performance. It includes a DVD RW optical drive and an HD Graphic 4000. The device is equipped with a 15.6" Full HD (1920x1080) display and a QWERTY keyboard (German layout). It comes pre-installed with Windows 7 Ultimate SP1, 64-bit (supporting de/en/fr/es/it languages) and includes a power supply cable for Italy. This model does not feature an S5 interface or an S5-EPROMMER. Software licenses for STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0 are included, along with an MPI cable. The software version is V13.0.1.0. Please note that STEP 5 and STEP 7-Micro/WIN are not pre-installed, and STEP 5 is not executable in Windows 7.

Features

  • Core I7-35X0M Processor (2.9 GHz, up to 3.6 GHz with Turbo Boost)
  • 16 GB RAM (2x 8 GB)
  • 300 GB SATA Solid State Drive
  • 15.6" Full HD (1920x1080) Display
  • DVD RW Optical Drive
  • HD Graphic 4000
  • Pre-installed Windows 7 Ultimate SP1, 64-bit (multi-language)
  • Includes licenses for STEP7 Prof combo, WinCC Advanced combo, and STEP 7 Micro/WIN V4.0
  • Supplied with MPI cable
  • QWERTY keyboard (German layout)

Applications

  • PLC programming and configuration
  • HMI and SCADA system development
  • On-site commissioning and diagnostics of automation systems
  • Industrial control system maintenance and troubleshooting
  • Engineering and development of automation projects

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG M4
Product Type Premium Programming Device
PLM Product Phase Phase-Out
Processor Core I7-35X0M (4M cache, 2.9 GHz, up to 3.6 GHz with Turbo Boost)
RAM 16 GB (2x 8 GB)
Storage 300 GB SATA Solid State Drive
Optical Drive DVD RW
Graphics HD Graphic 4000
Display 15.6" Full HD (1920 x 1080)
Operating System Windows 7 Ultimate SP1, 64-bit (de/en/fr/es/it)
Keyboard Layout QWERTY (German)
Power Supply Cable For Italy
S5 Interface Without
S5-EPROMMER Without
Included Software Licenses STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Included Cable MPI cable
Software Version V13.0.1.0
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Unpacking and Inspection: Carefully unpack the Field PG and inspect for any signs of shipping damage. Retain original packaging for potential future transport.
  2. Power Connection: Connect the provided power supply cable to the Field PG and a suitable mains outlet. Ensure the power source matches the device's requirements.
  3. Initial Boot-up: Power on the Field PG. The Windows 7 Ultimate SP1 operating system is pre-installed and should boot automatically. Follow any on-screen prompts for initial setup if required.
  4. Software Setup: While licenses for STEP7 Prof, WinCC Advanced, and STEP 7 Micro/WIN are included, verify their installation status. If not pre-installed, use the provided license keys and media (if applicable) for installation. Note that STEP 5 and STEP 7-Micro/WIN are not pre-installed, and STEP 5 is not executable in Windows 7.
  5. MPI Cable Connection: Utilize the included MPI cable for connecting to SIMATIC PLCs. Ensure proper connection to the Field PG's communication port and the PLC's MPI interface.
  6. Environmental Considerations: Operate the Field PG within typical industrial office or control room environments. Avoid exposure to extreme temperatures, excessive dust, or moisture.
  7. Security and Updates: Implement standard IT security practices, including regular operating system and software updates, to maintain system integrity.

FAQ

What is the processor specification of the SIMATIC Field PG M4?

It features a Core I7-35X0M processor with a 4M cache, running at 2.9 GHz, and capable of up to 3.6 GHz with Turbo Boost technology.

Which operating system is pre-installed on this device?

The device comes with Windows 7 Ultimate SP1, 64-bit, pre-installed, supporting German, English, French, Spanish, and Italian languages.

Does the 6ES7716-2CA14-0CB4 include an S5 interface?

No, this specific model is supplied without an S5 interface and without an S5-EPROMMER.

What software licenses are included with the Field PG M4?

It includes licenses for STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0.

What is the display resolution of the Field PG M4?

The device is equipped with a 15.6-inch display offering Full HD resolution (1920 x 1080).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.