Description
The Siemens 6ES7716-2CB16-0EC4 is a SIMATIC Field PG M4 Premium Plus programming device, engineered for industrial automation tasks. This robust mobile workstation features an Intel Core i7-35X0M processor with 4 MB cache, operating at 2.9 GHz (up to 3.6 GHz with Turbo Boost technology). It is equipped with 16 GB of RAM (2x 8GB) and a 300 GB SATA Solid-State Drive (SSD) for fast performance and reliable data storage. The device includes an S5 interface with an S5-EPROMMER, an S5-AG cable, and an EPROM adapter, facilitating compatibility with older Siemens S5 systems. It also features a DVD RW optical drive and HD Graphics 4000, displayed on a 15.6-inch Full HD (1920x1080) screen. The 6ES7716-2CB16-0EC4 supports dual-boot operation with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit) and comes with pre-installed software licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5, along with an MPI cable. It features an AZERTY (French) keyboard layout and includes a power supply cable suitable for DE, FR, NL, SP, BEL, OES, SWD, FIN regions.
Features
-
Model: SIMATIC Field PG M4 Premium Plus
-
Processor: Intel Core i7-35X0M (2.9 GHz, up to 3.6 GHz with Turbo Boost, 4 MB Cache)
-
RAM: 16 GB (2x 8GB)
-
Storage: 300 GB SATA Solid-State Drive (SSD)
-
Optical Drive: DVD RW
-
Graphics: HD Graphics 4000
-
Display: 15.6-inch Full HD (1920x1080)
-
Operating System: Dual Boot (Windows XP Professional SP3 and Windows 7 Ultimate SP1, 64-bit)
-
Pre-installed Software: STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5 (Software version V13.0.1.0)
-
Interfaces: S5 interface with S5-EPROMMER, MPI
-
Keyboard: AZERTY (French) layout
-
Included Accessories: S5-AG cable, EPROM adapter, MPI cable, regional power supply cable
Applications
The Siemens SIMATIC Field PG M4 is designed for a range of industrial automation applications, including:
- Programming, configuration, and commissioning of Siemens SIMATIC S7 and S5 PLCs.
- On-site diagnostics and troubleshooting for automation systems.
- Development and maintenance of HMI/SCADA projects using WinCC and WinCC flexible.
- Data backup and restoration for industrial controllers.
- Engineering tasks requiring a robust, portable computing platform in industrial environments.
Technical Specifications
| Parameter |
Value |
| Manufacturer |
Siemens |
| Range |
SIMATIC Field PG |
| Subrange |
Field PG M4 |
| Product Type |
Premium Plus Programming Device |
| PLM Product Phase |
Phase-Out |
| Processor |
Intel Core i7-35X0M |
| Processor Speed |
2.9 GHz (up to 3.6 GHz with Turbo Boost) |
| Processor Cache |
4 MB |
| RAM |
16 GB (2x 8GB) |
| Storage Type |
SATA Solid-State Drive (SSD) |
| Storage Capacity |
300 GB |
| Optical Drive |
DVD RW |
| Graphics |
HD Graphics 4000 |
| Display Size |
15.6 inches |
| Display Resolution |
Full HD (1920x1080) |
| Keyboard Layout |
AZERTY (French) |
| Operating System 1 |
Windows XP Professional SP3 |
| Operating System 2 |
Windows 7 Ultimate SP1 (64-bit) |
| Pre-installed Software |
STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5 |
| Software Version |
V13.0.1.0 |
| Included Cables |
S5-AG cable, MPI cable, Regional Power Supply Cable (DE, FR, NL, SP, BEL, OES, SWD, FIN) |
| Included Adapters |
EPROM adapter |
| Package Dimensions (Calculated) |
39.50 cm x 30.00 cm x 17.00 cm |
| Shipping Weight |
3.50 kg |
| Commodity Code |
84713000 |
| Export Control Regulations (ECCN) |
N |
| Country of Origin |
Germany |
Connections / Interfaces
- S5 Interface with S5-EPROMMER
- MPI (Multi-Point Interface)
- DVD RW Optical Drive
Installation Guidelines
-
Unpacking and Inspection: Carefully unpack the Field PG M4 and inspect for any visible shipping damage. Retain original packaging for potential future transport.
-
Power Connection: Connect the provided regional power supply cable to the Field PG M4 and a suitable mains outlet. Ensure the power source meets the device's electrical requirements.
-
Initial Boot-up: Power on the device. The dual-boot system allows selection between Windows XP Professional SP3 and Windows 7 Ultimate SP1. Select the appropriate operating system for your programming tasks.
-
Software Verification: Confirm that all pre-installed software, including STEP7 Professional, WinCC Advanced, STEP 7 Micro/WIN, and STEP 5, are correctly installed and licensed.
-
Peripheral Connections: Connect necessary programming cables, such as the S5-AG cable or MPI cable, to the respective interfaces on the Field PG M4 and the target PLC.
-
Environmental Considerations: Operate the Field PG M4 within a clean, dry environment, avoiding excessive dust, moisture, and extreme temperatures to ensure optimal performance and longevity.
-
Data Backup: Regularly back up critical project data and system configurations to external storage devices to prevent data loss.
-
Security: Implement appropriate security measures, including strong passwords and antivirus software, to protect the programming device and sensitive project data.