Siemens

Siemens 6ES7716-2DA14-0CB4 SIMATIC Field PG M4 Industrial Programming Device

SKU 6ES7716-2DA14-0CB4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2DA14-0CB4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.5 x 30.0 x 17.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-2DA14-0CB4 is a SIMATIC Field PG M4 Premium Plus industrial programming device, engineered for commissioning, servicing, and maintaining automation systems. This ruggedized laptop is equipped with a high-performance Intel Core i7-35X0M processor with a base clock of 2.9 GHz, 16 GB of RAM, and a fast 480 GB SATA solid-state drive for demanding engineering tasks. It comes pre-loaded with a comprehensive suite of Siemens automation software, including STEP 7 Professional and WinCC Advanced, providing a complete platform for PLC and HMI development. The device features a 15.6-inch Full HD display and includes an MPI cable for direct connection to SIMATIC controllers.

Features

  • Intel Core i7-35X0M processor with Turbo Boost technology up to 3.6 GHz.
  • 16 GB (2x 8 GB) of installed system memory.
  • 480 GB SATA solid-state drive for rapid application loading and project access.
  • 15.6-inch Full HD display with 1920x1080 resolution.
  • Pre-installed Windows 7 Ultimate SP1 (64-bit) operating system.
  • Includes combo licenses for STEP 7 Professional, WinCC Advanced, and STEP 7 Micro/WIN.
  • Equipped with a DVD RW optical drive for software installation and data backup.
  • Supplied with an MPI communication cable for connecting to automation hardware.

Applications

  • PLC programming and configuration for SIMATIC S7 controllers.
  • HMI and SCADA application development with WinCC.
  • On-site system commissioning and startup.
  • Industrial network diagnostics and troubleshooting.
  • Plant maintenance and field service operations.
  • Mobile engineering workstation for automation projects.

Technical Specifications

Specification Value
Brand Siemens
Model 6ES7716-2DA14-0CB4
Series SIMATIC Field PG M4 Premium Plus
Processor Intel Core i7-35X0M
Processor Base Clock 2.9 GHz
Processor Max Turbo Frequency 3.6 GHz
Processor Cache 4 MB
Memory (RAM) 16 GB (2 x 8 GB)
Storage 480 GB Solid-State Drive (SSD)
Storage Interface SATA
Optical Drive DVD RW
Graphics Intel HD Graphics 4000
Display 15.6 inch, Full HD
Display Resolution 1920 x 1080 pixels
Keyboard QWERTY (German layout)
Power Supply Cable For Italy
Operating System Windows 7 Ultimate SP1, 64-bit
OS Languages DE, EN, FR, ES, IT
Licensed Software STEP 7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Software Version V13.0.1.0
Legacy S5 Interface Not included
Legacy S5 EPROMMER Not included
Product Lifecycle Status Phase-Out
Shipping Weight 3.50 kg
Package Dimensions 39.5 x 30.0 x 17.0 cm
Commodity Code 84713000
ECCN N
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: Always use the manufacturer-supplied power adapter and cable. Use of incompatible power sources can cause permanent damage to the device and create a fire hazard. Ensure the work area is free from electrostatic discharge (ESD) risks before connecting to sensitive automation equipment.
  1. 1 Carefully unpack the Field PG and all accessories. Visually inspect for any signs of shipping damage before connecting to power.
  2. 2 Connect the provided power supply unit to the Field PG and a suitable mains outlet. Allow the battery to charge fully before initial mobile use.
  3. 3 Power on the device and complete the initial Windows operating system setup. Verify that all pre-installed Siemens software applications launch correctly.
  4. 4 Use the Automation License Manager tool to confirm the status of all included software licenses (STEP 7, WinCC, etc.).
  5. 5 For controller communication, connect the supplied MPI cable to the appropriate port on the Field PG and the target automation device. Configure the interface settings in the TIA Portal or SIMATIC Manager software before attempting to go online.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.