Siemens

Siemens 6ES7716-2DB10-0DC4 SIMATIC Field PG M4 Programming Device

SKU 6ES7716-2DB10-0DC4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2DB10-0DC4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-2DB10-0DC4 is a SIMATIC Field PG M4 Premium plus programming device designed for industrial automation tasks. This robust unit features an Intel Core i7-35X0M processor (2.9 GHz, up to 3.6 GHz with Turbo Boost technology and 4 MB cache), an HD Graphic 4000, and a 480 GB SATA Solid State Drive. It includes an integrated DVD RW optical drive and a 15.6-inch Full HD (1920x1080) display. The device is equipped with an S5 interface and an S5-EPROMMER, along with an S5-AG cable and EPROM adapter for legacy system support. For connectivity, an MPI cable is included. It features a QWERTY keyboard with German characters and comes with a line cable suitable for various European regions (DE, FR, NL, SP, BEL, OES, SWD, FIN). The Field PG M4 supports a dual-boot configuration with pre-installed Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit), complemented by 8 GB of RAM. It includes licenses for essential Siemens engineering software, such as STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5, with the software version being V13.0.1.0.

Features

  • Intel Core i7-35X0M Processor (2.9 GHz, up to 3.6 GHz Turbo Boost)
  • 15.6-inch Full HD (1920x1080) Display
  • 480 GB SATA Solid State Drive
  • 8 GB RAM
  • Dual Boot Operating System (Windows XP Professional SP3 / Windows 7 Ultimate SP1 64-bit)
  • Integrated S5 Interface with S5-EPROMMER
  • Pre-installed Software Licenses (STEP7 Prof combo, WinCC Advanced combo, STEP 7 Micro/WIN V4.0, STEP 5)
  • DVD RW Optical Drive
  • HD Graphic 4000
  • Includes S5-AG cable, EPROM adapter, and MPI cable

Applications

The SIMATIC Field PG M4 is suitable for a range of industrial automation applications, including:

  • Programming and configuration of SIMATIC S5 and S7 PLCs.
  • Development and commissioning of HMI projects using WinCC Advanced and WinCC flexible.
  • On-site diagnostics, maintenance, and troubleshooting of automation systems.
  • Upgrading and servicing legacy SIMATIC S5 installations.
  • General industrial engineering and development tasks requiring a robust, portable computing platform.

Technical Specifications

Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG M4
Product Type Premium Programming Device
Product Phase Phase-Out
Processor Intel Core i7-35X0M
Processor Speed 2.9 GHz (up to 3.6 GHz with Turbo Boost)
Processor Cache 4 MB
RAM 8 GB
Storage 480 GB SATA Solid State Drive
Optical Drive DVD RW
Graphics HD Graphic 4000
Display Size 15.6 inches
Display Resolution Full HD (1920 x 1080)
Keyboard Layout QWERTY (with German characters)
Operating System Dual Boot (Windows XP Professional SP3, Windows 7 Ultimate SP1 64-bit)
Pre-installed Software STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5
Software Version V13.0.1.0
Included Cables/Adapters S5-AG cable, EPROM adapter, MPI cable, Line cable (DE, FR, NL, SP, BEL, OES, SWD, FIN)
Commodity Code 84713000
Export Control Regulations (ECCN) N
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg

Connections / Interfaces

Interface Type Function
S5 Interface For connection to SIMATIC S5 PLCs and S5-EPROMMER functionality
MPI Interface For connection to SIMATIC S7 PLCs and HMIs via included MPI cable
DVD RW Optical Drive For software installation and data backup

Installation Guidelines

  1. Power Connection: Connect the Field PG M4 to a stable power source using the appropriate line cable for your region. Ensure the power supply meets the device's requirements to prevent damage.
  2. Environmental Considerations: Operate the device within its specified temperature and humidity ranges. Avoid direct exposure to dust, moisture, and excessive vibrations typical in industrial environments.
  3. Software Configuration: Upon initial startup, verify the dual-boot operating system configuration. Ensure all pre-installed Siemens engineering software (STEP7, WinCC, STEP 5) is correctly licensed and updated to the latest compatible version for your projects.
  4. Peripheral Connections: Connect the S5-AG cable and EPROM adapter for SIMATIC S5 programming. Use the MPI cable for connecting to SIMATIC S7 PLCs or HMIs. Ensure all cables are securely fastened.
  5. Data Management: Regularly back up project data and system configurations to external storage to prevent data loss. Utilize the 480 GB SSD efficiently for active projects.
  6. Security: Implement appropriate cybersecurity measures, including strong passwords and network segregation, especially when connecting to plant networks.
  7. Maintenance: Keep the device's cooling vents clear of obstructions to ensure proper airflow. Periodically check for software updates and system health.

FAQ

What is the primary function of the Siemens 6ES7716-2DB10-0DC4?

It is an industrial programming device designed for engineering, commissioning, and maintenance of Siemens SIMATIC S5 and S7 automation systems, including PLC and HMI programming.

What operating systems are pre-installed on this Field PG M4?

The device features a dual-boot configuration with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit) pre-installed.

Which Siemens software packages are included with the device?

It includes licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.

Does the 6ES7716-2DB10-0DC4 support programming for legacy SIMATIC S5 systems?

Yes, it includes an integrated S5 interface, S5-EPROMMER, S5-AG cable, and EPROM adapter for compatibility with SIMATIC S5 systems.

What are the key hardware specifications of this programming device?

It features an Intel Core i7-35X0M processor, 8 GB RAM, a 480 GB SATA Solid State Drive, HD Graphic 4000, and a 15.6-inch Full HD (1920x1080) display.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...