Siemens

Siemens 6GK5774-1FY00-0TA0 SCALANCE W774-1 M12 EEC IWLAN Access Point

SKU 6GK5774-1FY00-0TA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GK5774-1FY00-0TA0

  • Country of origin:Germany

  • Product Type: IWLAN Access Point

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 1800g

  • Dimensions: 0.10 x 0.10 x 0.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6GK5774-1FY00-0TA0 is an IWLAN Access Point from the SCALANCE W774-1 M12 EEC series, designed for robust industrial wireless communication. This module features one radio and two R-SMA antenna ports, supporting iFeatures via a key plug. It operates on IEEE 802.11a/b/g/h/n wireless standards across 2.4 GHz and 5 GHz frequency bands, delivering a gross data rate of 300 Mbit/s. Connectivity includes two M12 Ethernet ports, each supporting up to 100 Mbit/s, and an integrated 2-port PoE switch. The unit is powered by a redundant 24 V DC supply via M12 A-coded connectors, offers an IP30 protection rating, and operates within a temperature range of -30 degC to 65 degC. Security protocols such as WPA2/802.11i/e are supported, and the module features conformal coating for enhanced durability in harsh environments, complying with EN 50155 standards. The CERT ID is MSN-W1-M12-E2. The scope of delivery includes manuals on CD-ROM (English/German) and M12 sealing caps, intended for operation outside of USA/Israel.

Features

  • IWLAN Access Point functionality
  • Single radio with two R-SMA antenna ports
  • iFeatures support via key plug
  • IEEE 802.11a/b/g/h/n wireless standards
  • 2.4 GHz and 5 GHz frequency band operation
  • Gross data rate of 300 Mbit/s
  • Two M12 Ethernet ports (max. 100 Mbit/s each)
  • Integrated 2-port Power over Ethernet (PoE) switch
  • Redundant 24 V DC power supply
  • M12 A-coded connectors
  • IP30 protection rating
  • Operating temperature range: -30 degC to 65 degC
  • WPA2/802.11i/e security protocol support
  • Conformal coating for environmental protection
  • EN 50155 compliance

Applications

  • Industrial Wireless LAN (IWLAN) infrastructure
  • Mobile automation applications in harsh industrial environments
  • Railway and transportation systems requiring robust wireless communication
  • Distributed control systems needing reliable and secure wireless connectivity
  • Environments benefiting from redundant power supply and integrated switching capabilities

Technical Specifications

Attribute Value
Manufacturer Siemens
Brand Siemens
Range SCALANCE
Product Type IWLAN Access Point, Communication Module
Model Number 6GK5774-1FY00-0TA0
Wireless Standard IEEE 802.11a/b/g/h/n
Frequency Bands 2.4 GHz / 5 GHz
Gross Data Rate 300 Mbit/s
Antenna Ports 2 x R-SMA
Ethernet Ports 2 x M12 (max. 100 Mbit/s)
Integrated Switch 2-port PoE switch
Power Supply Redundant 24 V DC
Power Connectors M12 A-coded
Protection Rating IP30
Operating Temperature -30 degC to 65 degC
Security Protocols WPA2/802.11i/e
Coating Conformal coating
Cert ID MSN-W1-M12-E2
PLM Product Phase Active
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm
Shipping Weight 1.80 kg
Commodity Code 85176200
Export Control Regulations (ECCN) N

Connections / Interfaces

Connector Type Function
2 x R-SMA Antenna connection
2 x M12 Ethernet ports (up to 100 Mbit/s), with PoE support
M12 A-coded Redundant 24 V DC power supply input
Key Plug Slot iFeatures support

Installation Guidelines

  1. Power Supply: Connect the redundant 24 V DC power supply to the M12 A-coded power input ports. Ensure correct polarity and adequate power capacity.
  2. Antenna Connection: Attach compatible R-SMA antennas to the two R-SMA ports. Ensure antennas are securely fastened and positioned for optimal signal coverage.
  3. Ethernet Connection: Connect M12 Ethernet cables to the two M12 ports for wired network integration. These ports support up to 100 Mbit/s and provide Power over Ethernet (PoE).
  4. Mounting: Install the device in an environment suitable for its IP30 protection rating, typically within a protected enclosure or cabinet to shield against dust and moisture.
  5. iFeatures Key Plug: Insert the iFeatures key plug into its designated slot if advanced functionalities are required.
  6. Environmental Considerations: Ensure the operating environment remains within the specified temperature range of -30 degC to 65 degC. The conformal coating provides protection against condensation and corrosive gases.
  7. National Approvals: Observe and comply with all relevant national and regional approvals for wireless device operation in the deployment location. The device is specified for operation outside of USA/Israel.

Compliance and Certifications

  • EN 50155
  • Observe national approvals

FAQ

What is the primary function of the Siemens 6GK5774-1FY00-0TA0?

It functions as an Industrial Wireless LAN (IWLAN) Access Point, enabling wireless communication in industrial environments.

What wireless standards and frequencies does this access point support?

It supports IEEE 802.11a/b/g/h/n standards and operates on both 2.4 GHz and 5 GHz frequency bands.

What is the operating temperature range for the 6GK5774-1FY00-0TA0?

The device is designed to operate within a temperature range of -30 degC to 65 degC.

Does the access point include an integrated switch or PoE functionality?

Yes, it features an integrated 2-port PoE switch, allowing connected devices to be powered via the Ethernet cable.

What power supply is required for this SCALANCE module?

It requires a redundant 24 V DC power supply, connected via M12 A-coded connectors.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.