Siemens

Siemens 6GK5992-2AQ00-8AA0 SCALANCE X Media Module MM992-2ELH

SKU 6GK5992-2AQ00-8AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GK5992-2AQ00-8AA0

  • Country of origin:Germany

  • Product Type: Industrial Media Module

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 6.0 cm x 10.0 cm x 2.2 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6GK5992-2AQ00-8AA0 is a media module, model MM992-2ELH, designed for use with the SCALANCE X series of industrial Ethernet switches. This module provides two 1000 Mbit/s SC fiber optic ports for establishing long-distance network connections. It is engineered to support single-mode fiber optic cabling, enabling reliable data transmission over distances up to a maximum of 120 km. Please note, this product is in the 'Phase-Out' stage of its lifecycle, making it suitable for spare parts inventory and maintenance of existing systems.

Features

  • Provides two 1000 Mbit/s SC ports
  • Supports single-mode optical fiber
  • Enables long-distance communication up to 120 km
  • Designed as an accessory for SCALANCE X switches

Applications

  • Long-haul industrial network backbones
  • Connecting geographically dispersed facilities or control centers
  • High-bandwidth data links in utility, transportation, and manufacturing
  • Extending network infrastructure in large industrial campuses

Technical Specifications

Category Detail
Product Type Media Module
Model MM992-2ELH
Part Number 6GK5992-2AQ00-8AA0
Series SCALANCE X
Manufacturer Siemens
Product Lifecycle Status Phase-Out
Number of Ports 2
Port Type SC
Data Rate 1000 Mbit/s
Supported Fiber Type Single-mode optical
Maximum Transmission Distance 120 km
Shipping Weight 0.24 kg
Package Dimensions (Calculated) 6.0 cm x 10.0 cm x 2.2 cm
Country of Origin USA (Estimate)
Commodity Code 85176200
ECCN 5A002

Installation Guidelines

CRITICAL WARNING: Always de-energize the host SCALANCE switch and follow lock-out/tag-out (LOTO) procedures before installing or removing media modules. Failure to disconnect power can result in equipment damage and risk of electric shock. Handle fiber optic cables with care to avoid damage to the core and connectors.
  1. 1 Verify that the host SCALANCE X switch is powered down and that the target slot for the media module is clean and free of debris.
  2. 2 Use a properly grounded electrostatic discharge (ESD) wrist strap to prevent static damage to the module's electronic components.
  3. 3 Carefully unpack the MM992-2ELH module. Do not remove the protective dust caps from the SC ports until you are ready to connect the fiber optic cables.
  4. 4 Align the module with the guides in the empty slot on the SCALANCE switch and slide it in gently until it is fully seated and clicks into place.
  5. 5 Clean the ferrules of the single-mode fiber optic cables using appropriate fiber optic cleaning tools. Remove the dust caps from the module's SC ports and connect the cables.
  6. 6 Once all connections are secure, you may re-energize the SCALANCE switch. Verify the link status LEDs on the module to confirm a successful connection.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.