Description

The Siemens SIMATIC Field PG M4, model 6ES7716-2CB10-0EC3, is a ruggedized, portable industrial programming device engineered for commissioning, servicing, and maintaining automation systems. This Premium Plus configuration is equipped with a high-performance Intel Core i7-35X0M processor, 16 GB of RAM, and a 300 GB Solid-State Drive for rapid application performance. It features a dual-boot environment with both Windows 7 Ultimate (64-bit) and Windows XP Professional, providing compatibility with both modern TIA Portal projects and legacy systems. Critically, this model includes an integrated S5 interface, an S5-EPROMMER, and licenses for STEP 5, making it a comprehensive tool for supporting older SIMATIC S5 controllers alongside S7 systems.

Features

  • Processor: Intel Core i7-35X0M with up to 3.6 GHz Turbo Boost technology.
  • Memory: 16 GB RAM (2 x 8 GB modules) for demanding engineering applications.
  • Storage: 300 GB SATA Solid-State Drive (SSD) for fast boot and program loading.
  • Display: 15.6-inch Full HD widescreen display (1920 x 1080 resolution).
  • Operating System: Dual-boot capability with Windows 7 Ultimate SP1 (64-bit) and Windows XP Professional SP3.
  • Legacy Support: Integrated S5 interface and S5-EPROMMER for direct connection to SIMATIC S5 PLCs.
  • Software Suite: Pre-loaded with combo licenses for STEP 7 Professional (V13/2010), WinCC Advanced (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.
  • Optical Drive: Integrated DVD RW drive for software installation and data archiving.
  • Included Peripherals: Comes with an S5-AG cable, EPROM adapter, and MPI cable.

Applications

  • Commissioning and startup of industrial machinery and production lines.
  • Programming and configuration of SIMATIC S7, S5, and WinCC systems.
  • On-site plant maintenance, diagnostics, and troubleshooting.
  • System migration projects requiring support for both legacy and modern platforms.
  • Mobile engineering workstation for field service technicians and automation engineers.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Field PG M4
Model Number 6ES7716-2CB10-0EC3
Product Type Premium Plus Industrial Programming Device
Product Lifecycle Status Phase-Out
Processor Intel Core i7-35X0M
Processor Cache 4 MB
Processor Base Frequency 2.9 GHz
Max Turbo Frequency 3.6 GHz
Memory (RAM) 16 GB (2 x 8 GB)
Storage 300 GB Solid-State Drive (SATA)
Display 15.6 inch Full HD (1920 x 1080)
Graphics Intel HD Graphics 4000
Optical Drive DVD RW
Keyboard QWERTY (& German)
Operating System Dual-boot: Windows XP Professional SP3 / Windows 7 Ultimate SP1 (64-bit)
Included Interfaces S5 Interface, S5-EPROMMER
Included Software Licenses STEP 7 Prof Combo (V13/2010), WinCC Advanced Combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5
Included Accessories S5-AG Cable, EPROM Adapter, MPI Cable, Line Cable (DE, FR, NL, SP, BEL, OES, SWD, FIN)
Shipping Weight 3.50 kg
Package Dimensions (Calculated) 39.5 x 30.0 x 17.0 cm
Commodity Code 84713000
Export Control (ECCN) N (Not subject to EAR)
Country of Origin (Estimate) Germany

Installation and Handling Guidelines

CRITICAL WARNING: This device connects to live industrial control systems. Failure to follow safety procedures can result in equipment damage, production loss, or severe injury. Always perform a risk assessment before connecting to any machinery.
  1. 1 Upon receipt, carefully inspect the Field PG and its accessories for any signs of shipping damage. Do not use if the chassis or power adapter is compromised.
  2. 2 Use only the supplied power adapter and the appropriate regional line cable. Connect to a stable, grounded power source to prevent electrical noise and ensure safety.
  3. 3 Power on the device and verify the dual-boot menu appears. Select the required operating system (Windows 7 or Windows XP) based on the automation software you intend to use.
  4. 4 Before connecting to any PLC or industrial network, create a full backup or system image of the Field PG's hard drive. This is critical for disaster recovery.
  5. 5 Select the correct programming cable for the target system (e.g., MPI cable for S7-300/400, S5-AG cable for S5). Ensure a secure connection at both the Field PG and the controller port before initiating communication.
  6. 6 Observe electrostatic discharge (ESD) precautions when handling EPROMs with the S5-EPROMMER. Work in a static-safe environment and use a grounding wrist strap.

FAQ

What operating systems are installed on this Field PG?

This device features a dual-boot configuration with Microsoft Windows 7 Ultimate (64-bit) SP1 and Windows XP Professional SP3, providing flexibility for both modern and legacy software.

Does this unit support legacy SIMATIC S5 PLCs?

Yes, it is specifically equipped for S5 support. It includes a built-in S5 interface, an S5-EPROMMER, an S5-AG programming cable, and a pre-installed license for STEP 5 software.

What are the key software licenses included?

It comes with combo licenses for STEP 7 Professional (V13/2010), WinCC Advanced (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.

What is the storage drive type and capacity?

The device is equipped with a 300 GB SATA Solid-State Drive (SSD), which provides faster boot times and application performance compared to traditional hard drives.

What is the display resolution?

The 15.6-inch display has a Full HD resolution of 1920 x 1080 pixels, suitable for detailed engineering views in TIA Portal and other software.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...