Siemens

Siemens SIMATIC Field PG M4 6ES7716-2CB10-0EC3 Industrial Programming Device

SKU 6ES7716-2CB10-0EC3

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2CB10-0EC3

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.5 x 30.0 x 17.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens SIMATIC Field PG M4, model 6ES7716-2CB10-0EC3, is a ruggedized, portable industrial programming device engineered for commissioning, servicing, and maintaining automation systems. This Premium Plus configuration is equipped with a high-performance Intel Core i7-35X0M processor, 16 GB of RAM, and a 300 GB Solid-State Drive for rapid application performance. It features a dual-boot environment with both Windows 7 Ultimate (64-bit) and Windows XP Professional, providing compatibility with both modern TIA Portal projects and legacy systems. Critically, this model includes an integrated S5 interface, an S5-EPROMMER, and licenses for STEP 5, making it a comprehensive tool for supporting older SIMATIC S5 controllers alongside S7 systems.

Features

  • Processor: Intel Core i7-35X0M with up to 3.6 GHz Turbo Boost technology.
  • Memory: 16 GB RAM (2 x 8 GB modules) for demanding engineering applications.
  • Storage: 300 GB SATA Solid-State Drive (SSD) for fast boot and program loading.
  • Display: 15.6-inch Full HD widescreen display (1920 x 1080 resolution).
  • Operating System: Dual-boot capability with Windows 7 Ultimate SP1 (64-bit) and Windows XP Professional SP3.
  • Legacy Support: Integrated S5 interface and S5-EPROMMER for direct connection to SIMATIC S5 PLCs.
  • Software Suite: Pre-loaded with combo licenses for STEP 7 Professional (V13/2010), WinCC Advanced (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.
  • Optical Drive: Integrated DVD RW drive for software installation and data archiving.
  • Included Peripherals: Comes with an S5-AG cable, EPROM adapter, and MPI cable.

Applications

  • Commissioning and startup of industrial machinery and production lines.
  • Programming and configuration of SIMATIC S7, S5, and WinCC systems.
  • On-site plant maintenance, diagnostics, and troubleshooting.
  • System migration projects requiring support for both legacy and modern platforms.
  • Mobile engineering workstation for field service technicians and automation engineers.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Field PG M4
Model Number 6ES7716-2CB10-0EC3
Product Type Premium Plus Industrial Programming Device
Product Lifecycle Status Phase-Out
Processor Intel Core i7-35X0M
Processor Cache 4 MB
Processor Base Frequency 2.9 GHz
Max Turbo Frequency 3.6 GHz
Memory (RAM) 16 GB (2 x 8 GB)
Storage 300 GB Solid-State Drive (SATA)
Display 15.6 inch Full HD (1920 x 1080)
Graphics Intel HD Graphics 4000
Optical Drive DVD RW
Keyboard QWERTY (& German)
Operating System Dual-boot: Windows XP Professional SP3 / Windows 7 Ultimate SP1 (64-bit)
Included Interfaces S5 Interface, S5-EPROMMER
Included Software Licenses STEP 7 Prof Combo (V13/2010), WinCC Advanced Combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5
Included Accessories S5-AG Cable, EPROM Adapter, MPI Cable, Line Cable (DE, FR, NL, SP, BEL, OES, SWD, FIN)
Shipping Weight 3.50 kg
Package Dimensions (Calculated) 39.5 x 30.0 x 17.0 cm
Commodity Code 84713000
Export Control (ECCN) N (Not subject to EAR)
Country of Origin (Estimate) Germany

Installation and Handling Guidelines

CRITICAL WARNING: This device connects to live industrial control systems. Failure to follow safety procedures can result in equipment damage, production loss, or severe injury. Always perform a risk assessment before connecting to any machinery.
  1. 1 Upon receipt, carefully inspect the Field PG and its accessories for any signs of shipping damage. Do not use if the chassis or power adapter is compromised.
  2. 2 Use only the supplied power adapter and the appropriate regional line cable. Connect to a stable, grounded power source to prevent electrical noise and ensure safety.
  3. 3 Power on the device and verify the dual-boot menu appears. Select the required operating system (Windows 7 or Windows XP) based on the automation software you intend to use.
  4. 4 Before connecting to any PLC or industrial network, create a full backup or system image of the Field PG's hard drive. This is critical for disaster recovery.
  5. 5 Select the correct programming cable for the target system (e.g., MPI cable for S7-300/400, S5-AG cable for S5). Ensure a secure connection at both the Field PG and the controller port before initiating communication.
  6. 6 Observe electrostatic discharge (ESD) precautions when handling EPROMs with the S5-EPROMMER. Work in a static-safe environment and use a grounding wrist strap.

FAQ

What operating systems are installed on this Field PG?

This device features a dual-boot configuration with Microsoft Windows 7 Ultimate (64-bit) SP1 and Windows XP Professional SP3, providing flexibility for both modern and legacy software.

Does this unit support legacy SIMATIC S5 PLCs?

Yes, it is specifically equipped for S5 support. It includes a built-in S5 interface, an S5-EPROMMER, an S5-AG programming cable, and a pre-installed license for STEP 5 software.

What are the key software licenses included?

It comes with combo licenses for STEP 7 Professional (V13/2010), WinCC Advanced (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.

What is the storage drive type and capacity?

The device is equipped with a 300 GB SATA Solid-State Drive (SSD), which provides faster boot times and application performance compared to traditional hard drives.

What is the display resolution?

The 15.6-inch display has a Full HD resolution of 1920 x 1080 pixels, suitable for detailed engineering views in TIA Portal and other software.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.