Description
This device is a Siemens SIMATIC PANEL PC 670, model 6AV7615-0AA10-0BG0, designed for industrial human-machine interface (HMI) and control applications. It features an integrated 15-inch TFT display and is powered by a Celeron 300 MHz CPU. This standard configuration includes 64 MB of RAM and a 20 GB hard drive for local data storage and application hosting. The unit comes pre-installed with a multi-language version of Windows 2000 and includes a U.S. mains power cable. As an obsolete product, it serves as a direct replacement for existing installations requiring this specific hardware configuration.
Features
- Integrated 15-inch TFT color display
- Celeron 300 MHz processor
- 64 MB of installed system RAM
- 20 GB internal hard drive (HD)
- Pre-loaded with Windows 2000 (Multi-Language: EN, DE, FR, IT, ES)
- Includes a U.S. mains power cable for 115-230V AC operation
Applications
- Human-Machine Interface (HMI) for industrial machinery
- SCADA system visualization and control nodes
- Data logging and process monitoring stations
- Direct replacement for legacy systems in manufacturing and process control
Technical Specifications
| Specification |
Value |
| Product Type |
Panel PC |
| Display |
15-inch TFT |
| Processor (CPU) |
Celeron 300 MHz |
| Memory (RAM) |
64 MB |
| Storage |
20 GB Hard Drive (HD) |
| Operating System |
Windows 2000 (Multi-Language: EN, DE, FR, IT, ES) |
| Input Voltage |
115-230V AC |
| Included Accessories |
U.S. Mains Cable |
| Product Lifecycle Status |
Obsolete |
| Country of Origin |
USA |
| Manufacturer |
Siemens |
| Shipping Weight |
12.00 kg |
| Package Dimensions (Calculated) |
35.0 cm x 25.0 cm x 25.0 cm |
Installation Guidelines
CRITICAL WARNING: Risk of electric shock and equipment damage. All installation and maintenance activities must be performed by qualified personnel with the main power to the cabinet disconnected and locked out.
-
1
Verify that the control panel cutout dimensions match the PC 670's requirements. Ensure adequate clearance around the unit for proper ventilation and heat dissipation.
-
2
Before beginning installation, de-energize the main control cabinet power supply. Strictly follow all local Lockout/Tagout (LOTO) procedures to prevent accidental power-up.
-
3
Insert the Panel PC into the cutout from the front of the panel. Secure it evenly using the provided mounting clamps to ensure a proper seal against the enclosure.
-
4
Connect the included U.S. mains cable to the unit's power input and to a stable, properly grounded 115-230V AC power source. The power source must be protected by an appropriate circuit breaker.
-
5
Connect all necessary communication (e.g., Ethernet, serial) and peripheral cables. Route all low-voltage signal cables separately from high-voltage power lines to minimize electrical noise.
-
6
After double-checking all connections, remove all LOTO devices according to procedure. Re-energize the cabinet and proceed with system commissioning and software configuration.