Siemens

Siemens SIMOVERT MASTERDRIVES du/dt Filter 6SE7016-2FB87-1FD0-Z

SKU 6SE7016-2FB87-1FD0-Z

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6SE7016-2FB87-1FD0-Z

  • Country of origin:Germany

  • Product Type: Filters

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 20g

  • Dimensions: 48.30cm x 40.60cm x 35.60cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 6SE7016-2FB87-1FD0-Z is a du/dt filter from the SIMOVERT MASTERDRIVES series, manufactured by Siemens. This filter is designed to mitigate the steep voltage rise times (du/dt) generated by Pulse Width Modulation (PWM) in variable frequency drives. By limiting these voltage spikes, the filter protects motor insulation and cable systems from premature degradation, extending the lifespan of the drive-motor assembly in demanding industrial applications. Rated for both 380-460V AC (at 6.1A) and 500-575V AC (at 6.2A) systems, this robust component is a critical solution for maintaining process reliability.

Features

  • Voltage Spike Suppression: Effectively reduces the du/dt rate to protect motor windings and insulation.
  • Dual-Voltage Capability: Suitable for 380-460V AC and 500-575V AC three-phase power systems.
  • Masterdrives Compatibility: Specifically engineered for integration within the Siemens SIMOVERT MASTERDRIVES ecosystem.
  • Industrial Robustness: Designed to withstand the rigors of heavy-duty manufacturing environments.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range SIMOVERT MASTERDRIVES
Model 6SE7016-2FB87-1FD0-Z
Product Type du/dt Filter
Rated Current (380-460V) 6.1A
Rated Current (500-575V) 6.2A
Weight 20.00kg
Dimensions 48.30 x 40.60 x 35.60 cm
Commodity Code 85044095
PLM Product Phase Obsolete

Installation Guidelines

  • Ventilation: Due to the power dissipated by the filter, ensure it is installed in an enclosure with adequate forced-air ventilation.
  • Proximity: Install the filter as close to the drive output as possible to minimize the impact of cable length on voltage reflections.
  • Grounding: Secure a solid, low-impedance connection between the filter chassis and the system ground plate to ensure effective EMI shielding.
  • Cable Selection: Use shielded power cables between the filter and the motor to minimize radiated electromagnetic noise.
  • Safety: Because this is an obsolete unit, ensure all mounting brackets and electrical terminals are inspected for integrity before integration, and always perform installation with the power locked out.

FAQ

What is the function of a du/dt filter in a drive system?

A du/dt filter reduces the steepness of voltage rise times from a PWM drive, protecting motor insulation and reducing cable stress.

What voltage ranges is this filter compatible with?

It is rated for three-phase systems of 380-460V AC and 500-575V AC.

Is this product still in active production?

No, the 6SE7016-2FB87-1FD0-Z is currently classified as obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.

Magnetic Flowmeters: Commissioning and Diagnostics

A field-focused checklist for selecting, installing, commissioning, and diagnosing magnetic flowmeters, with emphasis on conductivity, full-pipe conditions, grounding, wiring, zero checks, and PLC...