The 6BK1700-2BA30-0AA0 is a SIPLUS HCS724I central connection module designed to interface industrial heating control systems with PROFIBUS DP networks at speeds up to 12 Mbaud. Manufactured by Siemens, this interface module manages communication between the control architecture and compatible power outputs such as the LA724I, LA724I HP, or LA724I SSR series units within demanding manufacturing environments.
The 6BK1700-2BA30-0AA0 is engineered to deliver reliable data transmission and network integration for specialized industrial heating applications. The unit features physical dimensions of 21.00 x 5.00 x 48.00 cm and weighs 5.22 kg. As a phase-out lifecycle product with a designated successor (6BK1942-1BA00-0AA0), it is utilized primarily for legacy system maintenance, direct hardware replacement, and operational continuity in established SIPLUS installations.
Features
SIPLUS HCS724I central connection module architecture
PROFIBUS DP network communication support up to 12 Mbaud
Compatibility with LA724I, LA724I HP, and LA724I SSR power output modules
Robust physical construction optimized for industrial control enclosures
Designed for phase-out system maintenance and replacement compatibility
Applications
Industrial heating control system network interfacing
SIPLUS HCS724I system communication management
PROFIBUS DP data acquisition and process control
Legacy heating infrastructure maintenance and repair
Technical Specifications
Technical Parameter
Specification
Manufacturer
Siemens
Brand
Siemens
Range
Siplus
Type of product
Interface modules
Product Phase
Phase-Out
Successor
6BK1942-1BA00-0AA0
Network Interface
PROFIBUS DP (up to 12 Mbaud)
Dimensions
21.00 x 5.00 x 48.00 cm
Weight
5.22 kg
Commodity Code
85389091
Export Control Regulations (ECCN)
EAR99
Installation Guidelines
Ensure all power to the control cabinet and connected heating infrastructure is completely switched off before installing or servicing the 6BK1700-2BA30-0AA0 module.
Mount the module securely within a designated industrial enclosure or rack backplate using appropriate mounting hardware.
Connect the PROFIBUS DP communication cable securely to the network port, ensuring proper termination and shielding to prevent interference.
Verify that compatible power output modules (LA724I, LA724I HP, or LA724I SSR) are correctly wired and configured before energizing the system.
FAQ
What is the primary function of the 6BK1700-2BA30-0AA0 module?
It functions as a SIPLUS HCS724I central connection module providing PROFIBUS DP communication up to 12 Mbaud.
Which power output modules are required for operation with this central connection unit?
It requires compatible power outputs such as the LA724I, LA724I HP, or LA724I SSR modules.
What are the physical dimensions and weight of the module?
The physical dimensions are 21.00 x 5.00 x 48.00 cm with an operating weight of 5.22 kg.
What is the designated successor product for this interface module?
The designated successor is model 6BK1942-1BA00-0AA0.
A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...
Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...
Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...
Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.
Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...
Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...