Engineered for medium-to-high complexity automation tasks, the Beckhoff CX5140-0122 Embedded PC brings quad-core processing power directly to the DIN rail. This controller integrates an Intel Atom E3845 1.91 GHz processor, providing high-speed execution for TwinCAT-based control systems. With native support for both E-bus and K-bus I/O terminals, the unit automatically detects connected modules, facilitating seamless migration and expansion in diverse industrial environments.

Key Technical Features

  • Quad-Core Processing: Intel Atom E3845 CPU running at 1.91 GHz for deterministic control loops.
  • Dual I/O Interface: Automatic recognition and support for Beckhoff E-bus (EtherCAT) and K-bus (Bus Terminal) systems.
  • Integrated 1-Second UPS: Hardware-based persistent memory protection (1 MB on CFast card) to prevent data loss during sudden power failures.
  • Robust Connectivity: Dual independent RJ45 Gigabit Ethernet ports, four USB 2.0 ports, and a DVI-I diagnostic interface.
  • Passive Thermal Design: Fanless operation across a wide temperature range from -25 to +60 degC.

Industrial Applications

  • Machine Tool Control: High-speed PLC and motion control execution via TwinCAT 3.
  • Process Automation: Distributed control systems requiring robust communication interfaces and fieldbus integration.
  • Infrastructure & Energy: Remote monitoring and control in substations, water treatment plants, and wind turbines.
  • Hazardous Environments: Deployable in Zone 2/22 locations when configured with the optional CX2900-0107 thermal/protection package.

Technical Specifications

Specification Parameter Value / Configuration
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number CX5140-0122
Processor Intel Atom E3845, 1.91 GHz (4 Cores)
System Memory 4 GB DDR3 RAM (Non-expandable)
Storage Slots 1 x CFast card slot, 1 x microSD card slot (Cards not included)
Persistent Memory Integrated 1-second UPS (1 MB on CFast card)
Communication Interfaces 2 x RJ45 (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0
I/O Bus Connection E-bus (EtherCAT) or K-bus (Bus Terminal), automatic recognition
E-bus/K-bus Current Supply 2 A maximum
Power Supply Input 24 V DC (-15% / +20%)
Power Consumption 16 W (Standard), 23 W (During UPS charging)
TwinCAT Platform Level Performance Plus (Level 50)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight 1095 g
Shipping Weight (Calculated) 3 kg
Country of Origin Germany

Alternative Models & Compatibility

The CX5140-0122 is a quad-core alternative to the dual-core CX5130 series. It operates at TwinCAT 3 Platform Level 50 (Performance Plus), meaning any licenses transferred from lower-tier controllers (such as Level 40 Economy Plus units) must be upgraded to match this platform level. It maintains physical and electrical backplane compatibility with existing CX5010 and CX5020 installations, though software configurations must account for the updated Intel Atom E3845 architecture.

Application Pitfalls & Engineering Notes

Thermal Management: Although fanless, the CX5140-0122 relies on natural convection. It must be mounted vertically on a horizontal DIN rail. Maintaining a minimum clearance of 30 mm above and below the unit is mandatory to prevent thermal throttling when operating near the upper limit of 60 degC.
UPS Functionality: The integrated 1-second UPS requires a functional internal capacitive storage system. This UPS is designed solely to write persistent data (up to 1 MB) to the CFast card during a power loss event; it is not a system-level runtime UPS. Ensure the TwinCAT boot project is configured to trigger the write routine on power loss.

Commissioning & Wiring Tips

When wiring the 24 V DC power supply, ensure the supply line is fused externally. The E-bus/K-bus auto-detection occurs during the initial boot phase. If changing terminal types (e.g., swapping K-bus terminals for EtherCAT E-bus terminals), a full system cold restart is required for the controller to re-map the physical backplane interface. Ensure the total current draw of connected terminals does not exceed the 2 A backplane limit; if exceeded, a power supply terminal (e.g., CX2100-0xxx) must be integrated.

Installation Guidelines

CRITICAL WARNING Disconnect all electrical power sources before mounting, wiring, or removing the CX5140-0122. Verify that the 24 V DC supply is completely de-energized. Failure to isolate power can result in permanent damage to the internal processor, backplane ASIC, or connected I/O terminals. Ensure electrostatic discharge (ESD) protection protocols are followed when handling CFast or microSD storage media.
1

Mount the CX5140-0122 onto a standard 35 mm DIN rail (EN 60715) by hooking the top of the mounting clip over the rail and pressing down until it snaps securely into place.

2

Connect the functional ground (PE) wire directly to the grounding terminal of the power supply connector to ensure proper EMC shielding and noise immunity.

3

Insert a compatible, industrially rated CFast card containing the operating system and TwinCAT runtime into the designated slot before applying power.

4

Connect the 24 V DC power cables to the terminal block, verifying correct polarity, and power on the system to initiate the automatic I/O bus scan.

Loading product navigation…

What is the TwinCAT 3 platform level for the CX5140-0122?

The CX5140-0122 is rated at TwinCAT 3 Platform Level 50 (Performance Plus). Ensure all runtime licenses match this level.

Can I use both E-bus and K-bus terminals simultaneously?

Yes, the CX5140-0122 features automatic bus recognition and can interface with either E-bus (EtherCAT) or K-bus (Bus Terminal) modules directly on the backplane.

How does the integrated 1-second UPS work?

The integrated UPS uses capacitive storage to provide power for approximately one second during a power outage. This is used exclusively to write up to 1 MB of persistent data to the CFast card.

Is the system memory expandable?

No, the 4 GB DDR3 RAM is integrated directly onto the motherboard and cannot be expanded or upgraded.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...