1 de 1

BECKHOFF EL6752-0010 EtherCAT Terminal DeviceNet Slave

BECKHOFF EL6752-0010 EtherCAT Terminal DeviceNet Slave

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: EL6752-0010

  • País de origem:Alemanha

  • Tipo de Produto: EtherCAT Terminals

  • Pagamento: T/T, Western Union

  • Peso: 70g

  • Dimensões: 24 mm x 100 mm x 52 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

To integrate modern control environments with existing network standards, the EL6752-0010 functions as a high-performance DeviceNet slave gateway designed for the EtherCAT Terminal system. This 1-channel communication interface enables high-speed data transfer and process image synchronization between an EtherCAT master and a primary DeviceNet master. Configured specifically as a DeviceNet slave, it allows seamless data exchange while keeping the networks galvanically isolated to prevent industrial noise and electrical interference from damaging sensitive controller electronics.

Housed in a compact 24 mm housing with standard signal LEDs for real-time status diagnostics, this module provides a reliable physical interface via a 5-pin open style connector. Integrating natively within the TwinCAT engineering environment, the terminal is engineered for rugged deployment in automated process environments requiring mixed-protocol network layouts.

Features

  • 1-channel fieldbus interface acting as a DeviceNet slave
  • Supported transmission rates of 125, 250, and 500 kbaud
  • Galvanically decoupled 5-pin open style physical connection
  • Status diagnostics through integrated hardware LEDs
  • Compact terminal design optimized for DIN rail mounting space
  • Direct integration with Beckhoff EtherCAT network architectures

Applications

  • Integration of legacy DeviceNet field devices into EtherCAT networks
  • Automotive manufacturing and assembly production lines
  • Material handling systems and distribution facilities
  • Process control systems and water treatment plants

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL6752-0010
Technology DeviceNet slave terminal
Fieldbus DeviceNet
Number of Channels 1
Data Transfer Rates 125, 250, 500 kbaud
Interface 5-pin open style connector (galvanically decoupled)
Current Consumption E-bus typ. 260 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Housing Material Polycarbonate
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Weight approx. 70 g
Wiring Connection Push-in connection

Connections and Interfaces

Connector Pin Function
Pin 1 V- (Power supply ground)
Pin 2 CAN_L (CAN low signal)
Pin 3 Shield (Drain/Shield wire)
Pin 4 CAN_H (CAN high signal)
Pin 5 V+ (DeviceNet network power)

Installation Guidelines

  • Mount the terminal onto a 35 mm DIN rail conforming to EN 60715, ensuring the integrated lock is fully engaged.
  • Utilize the built-in double slot and key connection system when mounting side-by-side with other EtherCAT terminals to secure E-bus power and data contacts.
  • Ensure fieldbus cabling is routed away from high-voltage motor lines to reduce risk of electromagnetic interference.
  • Maintain sufficient panel ventilation space to keep ambient temperatures within the designated operating limit of -25 degC to +60 degC.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc

What is the primary function of the Beckhoff EL6752-0010?

The Beckhoff EL6752-0010 functions as a 1-channel DeviceNet slave terminal, allowing a primary DeviceNet master to communicate and exchange I/O data directly with an EtherCAT terminal system.

What communication baud rates are supported by this module?

The module supports standard DeviceNet transfer rates of 125 kbaud, 250 kbaud, and 500 kbaud.

Is the 5-pin open style connector included with the module?

Yes, the 5-pin open style connector according to DeviceNet specifications is supplied with the terminal.

What are the environmental operating limits for the EL6752-0010?

The module operates reliably within a temperature range of -25 degC to +60 degC and with a maximum non-condensing relative humidity of 95%.

Does this terminal support hazardous area installations?

Yes, the EL6752-0010 features ATEX approval with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...