1 de 1

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: ER6001-0002

  • País de origem:Alemanha

  • Tipo de Produto: Serial Interface Modules

  • Pagamento: T/T, Western Union

  • Peso: 265g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for direct connection of serial devices to EtherCAT networks without an electrical cabinet, the Beckhoff ER6001-0002 serial interface module provides a highly ruggedized, IP67-rated solution for industrial field installations. This module enables the seamless integration of devices featuring RS232, RS422, or RS485 interfaces directly into the EtherCAT communication ring. The interface type is individually selectable per channel, allowing versatile configuration based on system requirements.

Equipped with an integrated 5 V DC sensor supply and auxiliary digital inputs and outputs, the ER6001-0002 serves as an all-in-one local connection point. Its heavy-duty zinc die-cast housing ensures superior resistance to mechanical stress, moisture, and electromagnetic interference, making it an ideal choice for decentralised control environments across heavy industries.

Features

  • Individually selectable serial interfaces: RS232, RS485, or RS422.
  • Robust 864-byte receive buffer and 128-byte transmit buffer to prevent data loss.
  • Two auxiliary 24 V DC digital inputs and two short-circuit proof digital outputs.
  • Dedicated +5 V DC, 1 A sensor power supply.
  • Standardised M12 connection technology for secure sensor and serial device coupling.
  • Integrated M8 EtherCAT bus interfaces with shielded, screw-type connection.
  • Fully encapsulated housing featuring IP65, IP66, and IP67 protection ratings.

Applications

  • Direct machine-level integration of barcode scanners, printers, and weight indicators.
  • Oil and gas field instrumentation and distributed telemetry systems.
  • Power generation and substation auxiliary device communication.
  • Water and wastewater plant field monitoring and control.

Technical Specifications

ManufacturerPart Number / ModelProduct SeriesProtocolSelectable InterfacesData Transfer RatesCommunication ModeData BufferSensor SupplyDigital InputsDigital OutputsBus InterfaceConnection MethodNominal VoltageCurrent ConsumptionElectrical IsolationOperating TemperatureStorage TemperatureProtection RatingWeight
Beckhoff
ER6001-0002
EtherCAT Box
EtherCAT
RS232, RS485, RS422
300 to 115,200 baud (9600 baud preset, 8N1)
TxD and RxD, full duplex
864 bytes receive buffer, 128 bytes transmit buffer
+5 V DC, 1 A
2 x digital inputs, 24 V DC (10 us filter, 11...30 V "1" signal)
2 x digital outputs, 24 V DC (0.5 A per channel, short-circuit proof)
2 x M8 socket, shielded, screw type
M12 x 1, 5-pin, A-coded
24 V DC (-15% / +20%)
Typically 130 mA + load
500 V
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Approx. 265 g

Connections and Interfaces

Interface Connection Connector Standard Functional Assignment
EtherCAT Bus Input/Output 2 x M8 Socket, Shielded EtherCAT fieldbus ring communication
Serial & I/O Connections M12 x 1, 5-pin, A-coded Serial transmit/receive data, auxiliary inputs, outputs, and sensor power
Power Supply Feed 1 x M8 Male Socket, 4-pin Control (US) and load voltage (UP) feed
Power Supply Downstream 1 x M8 Female Socket, 4-pin Downstream loop connection for power distribution

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate. No protective enclosure or cabinet is required thanks to the IP67 housing rating.
  • Ensure all M8 and M12 connectors are securely tightened to the specified torque to maintain the integrity of the environmental seal.
  • Use shielded cabling for all serial communication lines (RS232/RS422/RS485) and ensure the shield is properly terminated at the connector.
  • Keep total serial cable lengths within safe limits: maximum 15 m for RS232 connections, and up to 1000 m for RS422/RS485 networks.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27
Loading product navigation…

Which serial communication standards are supported by the ER6001-0002?

The Beckhoff ER6001-0002 supports RS232, RS422, and RS485 communication. The protocol is individually selectable depending on the connected end device.

What is the protection rating of this module?

The module has an IP65, IP66, and IP67 protection rating according to EN 60529, allowing it to be installed directly on machines without requiring a control cabinet.

What type of sensor supply does the module provide?

The module features an integrated +5 V DC sensor supply rated up to 1 A, which can power connected serial devices and sensors directly.

Are there digital inputs and outputs on the ER6001-0002?

Yes, the module includes 2 digital 24 V DC inputs with a 10 us input filter and 2 short-circuit proof digital 24 V DC outputs rated up to 0.5 A per channel.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...