Distributed control architectures requiring resilient, high-speed fiber-optic communications utilize the IP1001-B200 Lightbus fieldbus box to bridge field-level signals with centralized controllers. Designed by Beckhoff, this rugged I/O module integrates directly into the Lightbus ring topology, providing reliable data rates up to 2.5 Mbaud. Its optical fiber physical layer ensures complete immunity to electromagnetic interference (EMI), making it an excellent choice for environments with high electrical noise, such as welding cells or heavy machinery installations.

The IP1001-B200 is housed in a fully sealed enclosure, allowing direct machine mounting without an additional control cabinet. It features a dual-circuit power system that isolates the sensitive control electronics from the field load voltage. System configuration is executed seamlessly via the Beckhoff KS2000 software tool or directly through the master controller, simplifying deployment and diagnostic routines.

Features

  • High-speed Beckhoff Lightbus interface with 2.5 Mbaud transmission speed.
  • Dual fiber-optic connections utilizing ZS1020-0010 plug systems for optimal signal integrity.
  • Robust IP65/66/67 rating for reliable operation in dust, moisture, and washdown environments.
  • Isolated power supply distribution with dedicated M8 connectors for control voltage feed and downstream forwarding.
  • Flexible, orientation-independent physical installation.

Applications

  • Automotive manufacturing lines and robotic welding systems.
  • Packaging, food processing, and bottling plants requiring washdown protection.
  • Material handling systems and overhead cranes.
  • Heavy industrial machinery requiring distributed, EMI-immune control networks.

Technical Specifications

ManufacturerModel / Part NumberBus InterfaceData Transfer RateControl Voltage Power SupplyLoad Voltage Power SupplyPower Feed ConnectionDownstream Power ConnectionElectrical IsolationWeightOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection ClassInstallation PositionApprovals
Beckhoff Automation
IP1001-B200
2 x fiber-optic socket for plug ZS1020-0010
2.5 Mbaud
24 V DC (-15% / +20%)
Determined by connected I/O configuration
1 x M8 male connector, 4-pin
1 x M8 female connector, 4-pin
Yes (control voltage to fieldbus)
approx. 250 g
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65/66/67 (conforms to EN 60529)
Variable (any mounting orientation)
CE, UL

Connections and Interfaces

M8 Male (4-pin)M8 Female (4-pin)Fiber-Optic RxFiber-Optic Tx
Connection Type Interface Description
Feed: 24 V DC control voltage input
Downstream: 24 V DC power distribution loop
Lightbus optical receiver channel
Lightbus optical transmitter channel

Installation Guidelines

When installing the module, ensure the fiber-optic cables are routed to strictly maintain their minimum specified bend radius to prevent signal attenuation or physical damage. Mount the box securely to a flat surface using the integrated mounting holes. For installations requiring IP67 protection, all unused M8 and fiber-optic ports must be sealed using the appropriate protective caps, and mating connectors must be fully torqued according to manufacturer guidelines.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary communication protocol of the IP1001-B200?

The IP1001-B200 communicates using the Beckhoff Lightbus protocol, utilizing optical fibers for high noise immunity at transmission rates up to 2.5 Mbaud.

What power supply connections does this fieldbus box use?

It is equipped with a 4-pin M8 male connector for the main 24 V DC control voltage feed and a 4-pin M8 female connector for looping power downstream.

Is a protective enclosure required for this module?

No, because it features an IP65/66/67 environmental protection rating, the IP1001-B200 can be mounted directly on the machinery or in the field without an enclosure.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...