1 de 1

BECKHOFF IP3112-B528 Fieldbus Box

BECKHOFF IP3112-B528 Fieldbus Box

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: IP3112-B528

  • País de origem:Alemanha

  • Tipo de Produto: Fieldbus Boxes

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Dimensões: 2 x 2 x 0.25 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Decentralized installation in harsh environments requires robust interfaces. The Beckhoff IP3112-B528 is a high-performance Fieldbus Box designed to connect digital and analog peripheral signals directly to DeviceNet networks. It functions without requiring a protective control cabinet, utilizing standard M12 and M8 connector interfaces to distribute power and fieldbus communications. The module supports automatic baud rate detection up to 500 kbaud, streamlining commissioning and enhancing diagnostic flexibility via KS2000 configuration software or explicit messaging protocols. Built to withstand challenging plant environments, it provides reliable data transfer and localized control interface distribution.

Features

  • Direct integration into DeviceNet networks with integrated T-connector functionality.
  • Flexible I/O communication modes including polling, cyclic, bit strobe, and change of state (COS).
  • Robust IP65/66/67 housing for decentralized, cabinet-free field installation.
  • Dual-channel M12 fieldbus connections for easy loop-through topology.
  • Efficient M8 power connectors for control voltage feeding and downstream distribution.

Applications

  • Automotive assembly and welding lines.
  • Material handling and conveyor systems.
  • Food and beverage processing plants.
  • Decentralized sensor and actuator networks in high-moisture or dusty environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model IP3112-B528
Fieldbus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated tee-connector
Data Transfer Rates Automatic detection up to 500 kbaud
Data Transfer Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65/66/67 (conforms to EN 60529)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Connector Description Function
Fieldbus Input 1 x M12 plug, 5-pin DeviceNet incoming communication interface
Fieldbus Output 1 x M12 socket, 5-pin DeviceNet downstream loop-through connection
Power Feed 1 x M8 male socket, 4-pin Control voltage 24 V DC input
Power Downstream 1 x M8 female socket, 4-pin Control voltage daisy-chain to next box

Installation Guidelines

  • Mounting: Mount directly onto flat machine structures using the designated mounting holes. Ensure the surface is free of debris to maintain a secure seal.
  • Wiring: Use shielded copper cabling (typically 2 x 2 x 0.25 mm²) for DeviceNet transmission to preserve signal integrity and avoid EMI.
  • Grounding: Ensure the mounting surface or functional ground connection is correctly bonded to the plant's main ground potential.
  • IP Rating: Ensure all unused M8 and M12 interfaces are fitted with IP67-rated protective caps to maintain the unit's dust and moisture ingress resistance.

Compliance and Certifications

  • CE
  • UL

What communication protocol is supported by the Beckhoff IP3112-B528?

The IP3112-B528 is designed for DeviceNet networks, supporting automatic baud rate detection up to 500 kbaud.

What are the power connections on this Fieldbus Box?

It features a 24 V DC control voltage input via a 4-pin M8 male socket, and a loop-through downstream connection via a 4-pin M8 female socket.

Can this module be mounted outside a control cabinet?

Yes, with an IP65/66/67 rating, this unit is fully protected against dust, low-pressure water jets, and temporary immersion, making it suitable for direct machine mounting.

What configurations are possible for the I/O signals?

Configuration can be completed either via the Beckhoff KS2000 software package or directly through the main PLC controller using explicit messaging.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...