1 de 1

BECKHOFF KS4434 Bus Terminal

BECKHOFF KS4434 Bus Terminal

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: BECKHOFF

  • Nº do Produto: KS4434

  • País de origem:Alemanha

  • Tipo de Produto: Analog Output Modules

  • Pagamento: T/T, Western Union

  • Peso: 75g

  • Dimensões: 12 mm x 100 mm x 68 mm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Engineered for precise analog automation control, the BECKHOFF KS4434 analog output terminal delivers four channels of high-resolution control signals. Operating within a standard range of -10 to +10 V, this bus terminal features single-ended circuitry designed to drive analog actuators, control valves, and speed-controlled motor drives with precision.

A defining feature of the KS series is its pluggable wiring level, enabling fast, tool-free module replacement without disrupting existing system wiring. Integrating seamlessly into the Beckhoff K-bus system, the module transmits electrically isolated signals back to the automation controller, maintaining process stability and protecting sensitive upstream components from electrical noise.

Features

  • Four single-ended analog output channels.
  • Standard bipolar voltage signal range of -10 to +10 V.
  • 12-bit analog resolution for fine control loop adjustments.
  • Pluggable connection level for swift, minimized-downtime maintenance.
  • Short-circuit proof outputs with active load protection above 5 kOhm.
  • Robust electrical isolation rated up to 500 V between K-bus and signal circuits.
  • Direct DIN rail installation with reliable double-slot side-by-side locking.

Applications

  • Industrial machinery and process control systems.
  • Variable frequency drive speed setting regulation.
  • Proportional valve control in hydraulic and pneumatic systems.
  • HVAC ventilation, damper, and actuator positioning.
  • OEM manufacturing lines and assembly automation.

Technical Specifications

System & Electrical Parameters
Manufacturer BECKHOFF
Part Number / Model KS4434
Number of Outputs 4
Signal Voltage Range -10 to +10 V
Output Load > 5 kOhm (short-circuit proof)
Output Error < +/-0.1 % (relative to full-scale value)
Resolution 12 bit
Conversion Time ~ 4 ms
Electrical Isolation 500 V (K-bus / signal voltage)
Current Consumption K-bus Typ. 20 mA
Process Image Bit Width Output: 4 x 16-bit data (optional 4 x 8-bit control/status)
Current Load Power Contacts Max. 10 A
Mechanical & Environmental Data
Connection Technology Spring actuation (tension clamp)
Solid Wire Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Strand Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.075 kg
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Operating Temperature 0 to 55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20

Installation Guidelines

  • Mounting: Mount the bus terminal horizontally or vertically on a standard 35 mm DIN rail. Secure the terminal using the integrated lock mechanism.
  • Wiring: Use a flat-blade screwdriver to open the spring clamp terminal. Insert the stripped wire (9 to 10 mm stripping length) and release the clamp.
  • Shielding & Grounding: Ensure the analog signal cables are properly shielded to prevent electromagnetic interference from surrounding power circuits. Connect the shield to the ground plane closest to the entry point.
  • Pluggable Level: When servicing, slide the pluggable terminal connector out of the housing to disconnect wiring safely without terminal-by-terminal rewiring.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • DNV GL
Loading product navigation…

What is the key advantage of the BECKHOFF KS series over the standard KL series?

The KS series, including the KS4434, features a pluggable wiring level. This allows the terminal housing to be pulled out and replaced without disconnecting the field wiring, reducing maintenance time.

What signal range does the BECKHOFF KS4434 analog output terminal use?

The KS4434 outputs a bipolar voltage signal ranging from -10 V to +10 V.

Does the KS4434 require manual address configuration?

No, the KS4434 does not require manual address or hardware configuration settings; it is automatically mapped into the system's process image.

Is the analog output protected against short circuits?

Yes, the analog outputs are short-circuit proof with an active load protection recommended above 5 kOhm.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...