Description

Designed to stabilize supply voltages in highly dynamic drive systems, the **Beckhoff KS9570** buffer capacitor terminal provides reliable energy storage and overvoltage protection within the standard Bus Terminal system. This module absorbs regenerative energy generated during motor deceleration phases, protecting upstream power supplies and sensitive electronic components from overvoltage transients. Featuring a pluggable wiring level, the **KS9570 buffer capacitor** is fully compatible with all KSxxxx series Bus Terminals, allowing for rapid installation and simplified maintenance in demanding industrial environments.

Features

  • High-capacity 500 uF buffer for effective absorption of regenerative energy.
  • Integrated surge voltage protection threshold set above 56 V to safeguard field-side electronics.
  • Pluggable wiring level design for quick, tool-free terminal replacement without disconnecting field wiring.
  • Support for external braking resistor (recommended model ZB8110) with load-dependent 2-point control.
  • Robust electrical isolation of 1500 V between the K-bus and field potential.
  • Compact 12 mm housing width for optimized space utilization on standard DIN rails.

Applications

  • Dynamic motion control and servo drive systems.
  • Industrial manufacturing and packaging assembly lines.
  • Decentralized control cabinets requiring localized voltage stabilization.
  • Material handling systems with frequent start-stop and deceleration cycles.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model KS9570
Nominal Voltage 50 V
Capacity 500 uF
Ripple Current (max.) 10 A @ 100 kHz
Internal Resistance < 20 mOhm @ 100 kHz
Surge Voltage Protection > 56 V
Recommended Braking Resistor ZB8110
Overvoltage Control Range +/-2 V
Braking Resistor Clock Rate Load-dependent, 2-point control
Electrical Isolation 1500 V (K-bus/field potential)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Housing Material Polycarbonate
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.065 kg

Connections and Interfaces

Connection Parameter Specification
Wiring Method Spring actuation by screwdriver
Solid Wire Connection Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Stranded Wire Connection Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Flexible Wire Connection Cross-Section 0.14 to 1.5 mm2 (AWG 26 to 16)
Stripping Length 9 to 10 mm
Current Load Power Contacts (Imax) 10 A

Installation Guidelines

  • Mounting: Mount directly onto a standard 35 mm DIN rail conforming to EN 60715. Secure using the integrated locking mechanism.
  • Side-by-Side Installation: Align adjacent terminals using the double slot and key connection system to ensure proper mechanical stability and electrical contact.
  • Wiring: Use a suitable flat-head screwdriver to actuate the tension clamp spring. Insert stripped wire (9 to 10 mm stripping length) and release the spring to secure.
  • Ventilation: Ensure adequate clearance around the terminal housing to maintain operating temperatures within the specified 0 to +55 degC range.

Compliance and Certifications

  • CE
Loading product navigation…

What is the primary function of the Beckhoff KS9570?

The Beckhoff KS9570 is a buffer capacitor terminal designed to absorb regenerative energy and stabilize supply voltages in dynamic drive systems, protecting upstream components from overvoltage.

Which external braking resistor is recommended for the KS9570?

The recommended external braking resistor for use with the KS9570 terminal is the Beckhoff ZB8110.

What is the electrical isolation rating of this terminal?

The KS9570 features an electrical isolation of 1500 V between the K-bus and the field potential.

What wire sizes are compatible with the KS9570 terminal?

The terminal supports solid and stranded wires from 0.08 to 1.5 mm2 (AWG 28 to 16) and flexible wires from 0.14 to 1.5 mm2 (AWG 26 to 16).

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Alemanha

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...