1 de 1

Bently Nevada 24765-02-00 Case Expansion Transducer Assembly

Bently Nevada 24765-02-00 Case Expansion Transducer Assembly

Apenas 7 item(ns) restante(s) em estoque
  • Fabricante: Bently Nevada

  • Nº do Produto: 24765-02-00

  • País de origem:Estados Unidos

  • Tipo de Produto: Case Expansion Transducer Assemblies

  • Pagamento: T/T, Western Union

  • Peso: 320g

  • Dimensões: 24.1 cm x 11.7 cm x 8.9 cm (9.49 in x 4.61 in x 3.50 in)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

For the continuous tracking of thermal casing growth on large utility steam turbines, the Bently Nevada 24765-02-00 transducer assembly utilizes a direct-current linear variable differential transformer (DC-LVDT) to deliver precise absolute displacement feedback. This heavy-duty system converts physical axial movement into an analog DC voltage, allowing supervisory machinery protection systems to track structural expansion and prevent casing deformation or mechanical binding. By using a DC-powered design, the assembly simplifies the instrument loop by eliminating the need for external AC excitation and demodulator modules, transmitting a scaled signal directly to the control room or monitor rack.

Key Features

  • 50.8 mm (2.00 in) Linear Range: Optimized for mid-to-large-scale casing displacement tracking on industrial rotating machinery.
  • Without Spring Return (Option 00): Requires a rigid mechanical coupling directly to the sliding turbine foot or casing, ensuring the sensor rod follows bi-directional movement without relying on mechanical spring tension.
  • Direct-Current Operation: Integrated internal electronics accept DC power and output a clean, low-impedance DC voltage proportional to displacement.
  • Rugged Protective Housing: Constructed to withstand high humidity, oil mist, and thermal cycling common in power generation turbine decks.

Applications

  • Steam turbine thermal casing expansion monitoring.
  • Gas turbine structural growth tracking.
  • Boiler and feed pump foundation displacement measurements.
  • Heavy industrial structural expansion and mechanical alignment tracking.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada
Model Number 24765-02-00
Transducer Type Direct-Current Case Expansion Transducer (DC-LVDT)
Linear Range Option 02 (50.8 mm / 2.00 inches)
Spring Return Option 00 (Without spring return; rigid coupling required)
Scale Factor 0.404 V/mm (10.25 V/inch) nominal
Frequency Response (-3 dB) 15 Hz
Operating Temperature -30 to +100 degC
Country of Origin United States (USA)
Device Weight 2.3 kg (5.07 lbs)
Shipping Weight (Calculated) 3.5 kg (7.71 lbs)
Package Dimensions (Calculated) 24.1 cm x 11.7 cm x 8.9 cm (9.49 in x 4.61 in x 3.50 in)

Empirical Engineering Insights

Alternative Models & Compatibility

The Bently Nevada 24765-02-00 is directly compatible with the 3500/45 Position Monitor or older 3300-series position monitors configured for DC-LVDT inputs. When replacing an older AC-LVDT case expansion assembly, be aware that you must bypass or remove any external AC demodulator units, as the 24765 handles excitation and conditioning internally. Ensure the monitoring system channel card is configured for DC voltage input with the correct scale factor (10.25 V/in) to avoid erroneous calibration curves.

Application Pitfalls & Engineering Notes

Because this specific assembly utilizes the Option 00 (no spring return), the sensor core rod does not automatically retract. The rod must be mechanically pinned, bolted, or tethered via a yoke assembly to the turbine casing. If this physical connection is lost or slips during thermal cycling, the transducer will remain in its last physical position, causing the monitoring system to report a static "flatline" signal. Additionally, any side loads or angular misalignment during casing movement will cause internal friction, wearing out the PTFE support bushings and creating measurement stiction.

Commissioning & Wiring Tips

When installing the transducer in cold machinery conditions, adjust the mechanical coupling so that the LVDT core sits near the negative end of its physical stroke. This maximizes the usable positive measurement range as the steam turbine heats up and expands. Ensure the field wiring shield is grounded only at the 3500 monitor rack terminal block; leaving both ends of the shield grounded can create ground loops due to potential differences between the turbine foundation and the control room instrument ground.

Installation Guidelines

CRITICAL WARNING

Ensure the turbine is completely shut down, de-energized, and cooled to ambient temperature before attempting installation or physical adjustment of the transducer assembly. Structural casing movements during cooldown present severe crushing hazards. Disconnect all associated monitoring loop power to prevent transient surges from damaging the internal LVDT electronics during wiring.

1

Mount the heavy protective housing securely to the rigid turbine foundation plate or pedestal, ensuring alignment parallel to the direction of casing growth.

2

Mechanically link the LVDT rod end to the casing bracket or sliding foot. Verify that there is zero angular offset or binding across the entire 50.8 mm stroke.

3

Connect the DC power supply lines and signal output cables inside the integrated junction box, utilizing flexible conduit to isolate the housing from turbine vibrations.

What is the primary difference between Option 00 and a standard spring-return model?

Option 00 lacks an internal return spring. This means the transducer rod must be mechanically pinned or coupled to the moving turbine casing in both directions. It will not automatically retract on its own.

Does the 24765-02-00 require an external AC excitation module?

No. The 24765-02-00 is a direct-current (DC) LVDT. It accepts DC voltage input and outputs a DC signal, containing internal electronics to handle high-frequency excitation and signal demodulation.

How do I calibrate the zero point on a cold turbine?

Adjust the mechanical connection so that when the turbine casing is completely cold, the transducer is positioned close to its mechanical stop at the negative limit. This preserves the maximum positive travel for casing thermal growth.

What are the common failure modes of this transducer assembly?

Common issues include core-rod binding caused by mechanical misalignment, flatlining signals due to loose mechanical couplings, and signal drift from high-vibration structural environments.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Fluidos: Tutorial Prático

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...