Description
Optimized for continuous machinery protection and diagnostic monitoring, the Bently Nevada 330104-00-17-10-11-00 is an eddy current proximity probe belonging to the industry-standard 3300 XL 8 mm series. This non-contacting sensor measures static (gap) and dynamic (vibration) distances between the probe tip and the target shaft. It is specifically configured with an M10 x 1 thread, a fully threaded casing option, and a 1.0-meter system length. Equipped with a coaxial ClickLoc connector and FluidLoc cable, this probe prevents process fluids from migrating through the internal structure of the cable, ensuring reliable performance in harsh industrial environments.
Features
-
FluidLoc Cable Technology: Prevents moisture, oil, and process fluids from leaking through the cable interior.
-
ClickLoc Coaxial Connector: Heavy-duty connection mechanism with an integrated connector protector to prevent mechanical decoupling and dust ingress.
-
Fully Threaded Case: 0 mm unthreaded portion with a robust 170 mm overall case length for precise positioning inside deep-well machine housings.
-
High Temperature Stability: Designed to maintain accurate measurement characteristics across demanding industrial temperature profiles.
-
Broad Interoperability: Seamlessly integrates with Bently Nevada 3300 XL Proximitor Sensors and extension cables.
Applications
- Steam and gas turbine shaft vibration and axial position monitoring.
- Centrifugal compressor thrust and radial displacement measurements.
- Gearbox bearing wear analysis and high-speed shaft tracking.
- Boiler feed pump shaft dynamics monitoring in power generation plants.
- Hydroelectric generator shaft alignment and runout tracking.
Ordering Information
| Option Code |
Configuration Parameter |
Selected Specification |
| 00 |
Unthreaded Length |
0 mm (Fully Threaded Case) |
| 17 |
Overall Case Length |
170 mm |
| 10 |
Total Length |
1.0 meter (3.3 feet) |
| 11 |
Connector & Cable Type |
Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable |
| 00 |
Agency Approval |
Not Required |
Technical Specifications
| Parameter |
Value / Specification |
| Manufacturer |
Bently Nevada |
| Part Number / SKU |
330104-00-17-10-11-00 |
| Probe Tip Diameter |
8 mm |
| Thread Profile |
M10 x 1 (metric) |
| Linear Range |
2.0 mm (80 mils) nominal |
| Operating Temperature Range |
-51 degC to +177 degC (-60 degF to +350 degF) |
| Scale Factor Compatibility |
7.87 V/mm (200 mV/mil) with matched proximitor |
| Cable Type |
75-ohm coaxial FluidLoc cable |
| Connector Style |
Miniature ClickLoc (male) |
| Net Weight |
0.323 kg (0.71 lbs) |
| Shipping Weight (Calculated) |
1.500 kg (3.31 lbs) |
| Country of Origin |
United States (U.S.A) |
Empirical Engineering Insights
To ensure long-term stability in hazardous industrial processes, engineers must evaluate key physical and electrical parameters during system installation.
Alternative Models & Compatibility
The 330104 series probes must be matched with a Proximitor Sensor of the correct total system length. Because this probe features a 1.0-meter total length, it requires a 4.0-meter extension cable to configure a 5.0-meter total system, or an 8.0-meter extension cable to configure a 9.0-meter total system. Intermixing 5-meter probes with 9-meter sensor electronics will cause severe calibration scale factor errors.
Application Pitfalls & Engineering Notes
Because this probe has an overall case length of 170 mm with 0 mm unthreaded portion, any misalignment during insertion can cause cross-threading in the mounting hole. When installing in a deep housing, check for thread burrs. Avoid bending the FluidLoc cable beyond its minimum dynamic bend radius of 25.4 mm (1.0 inch) to prevent internal micro-fractures in the coaxial shielding.
Commissioning & Wiring Tips
During commissioning, verify the physical gap voltage matches the design setpoint (typically -10 VDC for mid-range calibration) using a calibrated digital multimeter before securing the locknut. Ensure the ClickLoc connector protector is fully seated; this prevents machine vibration from rubbing the connector contact surfaces, which manifests as high-frequency noise spikes in control room trends.
Installation Guidelines
CRITICAL WARNING
Verify the machinery has been fully de-energized, locked out, and tagged out (LOTO) prior to mounting the probe. Keep the sensor tip away from strong magnetic fields during installation. Do not exceed the maximum installation torque of 4.5 N-m (40 in-lb) for M10 threads.
1
Carefully clean and inspect the internal M10 x 1 mounting thread of the bracket or sleeve, removing any oily residues or particulate matter.
2
Thread the probe by hand into the sleeve until the tip gently contacts the target surface (shaft) to establish the zero point.
3
Back the probe out of the mounting hole by the specified distance to meet the target gap voltage (usually around 1.27 mm for standard calibration ranges).
4
Tighten the probe locknut to 4.5 N-m using a torque wrench. Avoid twisting the cable during final tightening.
5
Route the FluidLoc cable inside a dedicated protective conduit, avoiding sharp bends, and connect to the extension cable with the protector sleeve securely closed.