Description

Option 05 (5.0 mm unthreaded length), Option 30 (30 mm case length), Option 50 (5.0 m total length), and Option 12 (ClickLoc connector with FluidLoc cable) specify this 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe with China hazardous area approvals (-CN).

This reverse-mount probe configuration features M10 x 1 metric threads and is engineered for installation inside machine casings or sleeves where standard forward-mounting is physically restricted. Unlike standard probes utilizing standard coaxial cables, this variant integrates a FluidLoc cable (Option 12), which provides a block against oil or process fluids from migrating along the cable via capillary action. Additionally, the 5.0-meter integral probe cable (Option 50) matches perfectly with a 5-meter 3300 XL Proximitor sensor, eliminating the need for an intermediate extension cable in specific turbine housing mounting layouts.

Features

  • Option 05 unthreaded length provides a precise 5.0 mm (0.20 in) clearance at the mounting base.
  • Option 30 case length specifies a 30 mm (1.2 in) total metric threaded housing of M10 x 1 thread size.
  • Option 50 designates a 5.0-meter (16.4 feet) total integral probe cable length for direct connection to 5-meter Proximitor systems.
  • Option 12 incorporates a FluidLoc cable and a miniature coaxial ClickLoc connector to halt oil leakage along the cable core.
  • Suffix -CN certifies the assembly for China hazardous area environments under NEPSI and CCC regulations.
  • Polyphenylene sulfide (PPS) probe tip provides chemical and thermal isolation up to 177 degC (350 degF).
  • AISI 303 or 304 stainless steel case offers structural protection in high-vibration machinery casings.

Applications

  • Axial position and radial vibration measurements in heavy industrial rotating machinery.
  • High-pressure casing penetration where FluidLoc technology prevents lubricating oil migration.
  • Reverse-mount turbine bearing housing installations with limited external access.
  • Petrochemical and power generation installations in China requiring NEPSI and CCC hazardous area compliance.

Ordering Information

Option Segment Code Value Meaning / Description
Orderable Part Number 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe (M10 x 1 threads)
Segment A (Unthreaded Length) 05 5.0 mm (0.20 in) unthreaded length
Segment B (Overall Case Length) 30 30 mm (1.2 in) case length
Segment C (Total Length) 50 5.0 meters (16.4 feet) total length
Segment D (Connector & Cable) 12 Miniature ClickLoc coaxial connector, FluidLoc cable
Suffix -CN (Agency Approval) -CN China hazardous area approval package (NEPSI + CCC)

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330106-05-30-50-12-CN
Probe Tip Diameter 8.0 mm (0.31 in)
Thread Size M10 x 1 (Metric)
Unthreaded Length 5.0 mm (0.20 in)
Overall Case Length 30 mm (1.2 in)
Total Probe Length 5.0 meters (16.4 feet)
Cable Type 75 Ohm FluidLoc triaxial cable
Connector Type Miniature ClickLoc coaxial connector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel (SST)
Operating Temperature (Probe) -52 degC to +177 degC (-62 degF to +350 degF)
Maximum Rated Pressure Designed to seal differential pressure between tip and case
Tensile Strength (Maximum Rated) 330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) lead to connectors
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Connector Torque (Maximum) 0.565 Nm (5 in-lbf)
Probe Case Torque (Maximum) 22.6 Nm (200 in-lbf) for reverse-mount probes
Nominal DC Resistance 7.45 to 9.87 Ohms depending on overall circuit (8.73 Ohms typical for 5.0m probe)
Dimensions 250 mm x 250 mm x 50 mm (H x W x D) (coiled probe envelope)
Weight 1.65 kg (3.64 lb)

Installation Guidelines

  • Reverse-mount probes are installed from the inside or inside a dedicated probe sleeve/housing.
  • Observe the minimum permissible cable bend radius of 25.4 mm (1.0 in) to prevent internal conductor damage.
  • Hand-tighten the ClickLoc coaxial connector to avoid stripping gold-plated surfaces; do not exceed 0.565 Nm (5 in-lbf).
  • Mount the probe-to-extension cable junction in a clean dry location; avoid exposing connectors directly to aggressive turbine lubricating oil without a protective sleeve.
  • Ensure the probe case torque does not exceed 22.6 Nm (200 in-lbf) during reverse-mount seating in the M10 x 1 threaded housing.

Compliance and Certifications

  • NEPSI (National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation)
  • CCC (China Compulsory Certification)
  • Hazardous area explosion-proof markings as specified by the -CN package
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330106-05-30-50-12-CN 3300 XL 8 mm Reverse Mount Proximity Probe

What does the "12" connector option represent on this probe?

The Option 12 code specifies a miniature ClickLoc coaxial connector paired with a FluidLoc cable. This specialized cable prevents machinery oil or process fluids from leaking or migrating along the cable core via capillary action.

Why is this model termed a reverse-mount probe?

The reverse-mount configuration (model 330106) has the threads positioned near the probe tip instead of the back of the case. This allows the probe to be installed through the inside of machine housings or sleeves where standard external thread mounting is not feasible.

Can this 5.0-meter probe be used with a 9-meter Proximitor sensor?

No, 5.0-meter proximity probes are engineered specifically for use with a 5-meter Proximitor sensor only. Operating this probe with a 9-meter sensor will disrupt system calibration and cause incorrect output.

What certifications does the -CN suffix provide?

The -CN suffix designates the China hazardous area approval package, which includes official NEPSI explosion-proof certification and CCC (China Compulsory Certification) markings for industrial installations in China.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...