  • Fabricante: Bently Nevada

  • Nº do Produto: 330195-02-12-90-CN

  • País de origem:Estados Unidos

  • Tipo de Produto: Vibration Monitoring Extension Cables

  • Pagamento: T/T, Western Union

  • Peso: 320g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Optimized for demanding machinery protection applications, the Bently Nevada 330195-02-12-90-CN functions as a high-performance 3300 XL 8 mm Extension Cable within the standard eddy current transducer system. This cable bridges the physical distance between the proximity probe and the Proximitor sensor, ensuring precise capacitive and inductive matching necessary for accurate vibration and shaft position measurements. Featuring FluidLoc technology and an integrated connector protector, this model is specifically engineered to resist process fluid migration and mechanical stress in harsh industrial environments, while carrying the necessary regional certification approvals.

Features

  • FluidLoc Cable Design: Prevents the leakage of oil, water, or other process fluids through the inner core of the coaxial cable.
  • Connector Protector: Provides robust mechanical shielding and environmental sealing at the critical probe-to-extension-cable junction.
  • Precision Coaxial Shielding: Minimizes electromagnetic interference (EMI) and radio frequency interference (RFI) to maintain signal integrity over the entire length.
  • High Temperature Stability: Constructed with materials designed to withstand extreme temperature fluctuations within industrial casings.
  • Certified Design: Designed with the CN option, meeting regional compliance and hazardous area standards.

Applications

  • Steam and gas turbine shaft vibration and axial displacement monitoring.
  • Centrifugal compressor and high-pressure pump shaft dynamic motion analysis.
  • Hydroelectric generator thrust collar and guide bearing monitoring.
  • Heavy industrial gearbox shaft thrust and radial position tracking.

Technical Specifications

Manufacturer Bently Nevada
Model Number 330195-02-12-90-CN
Product Series 3300 XL 8 mm Proximity Transducer System
Cable Length 2.0 meters (6.6 feet)
Total System Length Compatibility 9.0 meters (29.5 feet)
Cable Configuration Option FluidLoc Cable with Connector Protector
Agency Approvals CN Option (Country-specific approvals / hazardous area certifications)
Operating Temperature Range -51 degC to +177 degC (-60 degF to +350 degF)
Nominal Impedance 75 ohms
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 1.5 kg (3.3 lbs)

Connections and Interfaces

Connection Port Connector Type Protective Feature
Probe Interface Miniature Coaxial Male Integrated Connector Protector installed
Proximitor Sensor Interface Miniature Coaxial Female Standard silicon protective boot compatible

Empirical Engineering Insights

Alternative Models & Compatibility: The 330195-02-12-90-CN is strictly calibrated for 9.0-meter system configurations. It cannot be combined with a 5.0-meter Proximitor sensor or 5.0-meter probe configurations. Mismatching system lengths alters the total electrical capacitance of the sensor loop, leading to severe measurement non-linearity, gain errors, and invalid machinery protection alarms.

Application Pitfalls & Engineering Notes: When routing the extension cable, mechanical protection is paramount. Maintain a minimum bend radius of 25.4 mm (1.0 inch). Kinking or flattening the cable distorts the coaxial spacing between the center conductor and the outer shield, changing the characteristic impedance from 75 ohms and introducing high-frequency noise spikes that can be misidentified as machine vibration.

Commissioning & Wiring Tips: Ensure that the miniature coaxial connectors are completely clean and dry before mating. Moisture or particulate ingress inside the connector creates a high-resistance parallel path to ground, generating a drift in the gap voltage and triggering sensor fault codes in the 3500 rack. The FluidLoc and connector protector features must be correctly engaged and sealed during the final layout.

Installation Guidelines

CRITICAL WARNING

Ensure the machinery is completely de-energized, locked out, and tagged out (LOTO) prior to accessing probe housings. Discharge all residual electrostatic charges from your body and routing conduits before handling the coaxial connectors to prevent permanent electrostatic damage to the connected Proximitor sensor.

1
Route the extension cable through dedicated, grounded metal conduit. Avoid running the coaxial cable in the same cable trays or parallel paths with high-voltage AC power lines.
2
Connect the miniature coaxial interfaces carefully. Tighten the connectors to the recommended finger-tight torque. Do not use pliers or heavy tools on the miniature connectors, as this will strip the threads.
3
Slide the connector protector over the mated junction until it is firmly locked, providing mechanical and environmental sealing against steam, oil, and humidity.
Loading product navigation…

What does the -12 option signify in the 330195-02-12-90-CN model code?

The -12 option represents the FluidLoc cable configuration with an integrated connector protector. The FluidLoc technology prevents fluids from traveling inside the cable core, while the protector guards the physical coaxial joint from environmental contamination.

What is the physical length of the 330195-02-12-90-CN extension cable?

The physical cable length is 2.0 meters (6.6 feet), specified by the -02 option. The -90 option indicates it is calibrated for use in a total system length of 9.0 meters (29.5 feet).

Can I use this cable with non-XL 3300 series proximity probes?

Yes, but with limitations. While physical connections are compatible, mixing 3300 and 3300 XL components can affect system calibration parameters. For maximum accuracy and compliance, it is highly recommended to pair with other 3300 XL series components.

What are the grounding requirements for the 330195 extension cable?

The outer shield of the extension cable is electrically isolated from the machinery ground inside the conduit. System grounding must be handled solely at the Proximitor sensor side to prevent electrical ground loops that introduce signal noise.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...