Description

Designed specifically for industrial turbomachinery protection, the Bently Nevada 330703-000-060-10-11-00 provides high-accuracy non-contact shaft displacement and vibration measurement. This 3300 XL 11 mm Proximity Probe is engineered to withstand harsh, high-pressure environments, using specialized materials and construction to deliver long-term calibration stability in critical machine monitoring systems.

Features

  • FluidLoc Cable Technology: Prevents oil, water, and other process fluids from leaking through the interior of the coaxial cable.
  • ClickLoc Coaxial Connector: Features an integrated connector protector that guards the coaxial connection from moisture, dirt, and mechanical stress.
  • Polyphenylene Sulfide (PPS) Tip: Molded tip provides high resistance to chemical attack and thermal degradation.
  • Corrosion-Resistant Case: Manufactured from AISI 304 stainless steel to ensure mechanical strength in aggressive atmospheres.

Applications

  • Steam and gas turbine radial vibration and axial thrust position tracking.
  • Hydroelectric generator shaft alignment and thermal expansion monitoring.
  • High-speed industrial compressor and boiler feed pump bearing diagnostics.

Ordering Information

Option Code Selected Configuration Value Description
000 Unthreaded Length 00 mm
060 Overall Case Length 60 mm
10 Total Length 1.0 meter (3.3 feet)
11 Connector / Cable Type Miniature coaxial ClickLoc connector with protector, FluidLoc cable
00 Agency Approvals Not required

Technical Specifications

Parameter Specification Value
Probe Diameter 11 mm
Linear Range 4.0 mm (160 mils) nominal
System Scale Factor 3.93 V/mm (100 mV/mil) when paired with 3300 XL 11mm Proximitor
Operating Temperature -51 to 177 degC (-60 to 351 degF)
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Cable Impedance & Type 75 ohm triaxial, fluoroethylene propylene (FEP) insulated
Connector System Miniature coaxial ClickLoc with protective sleeve
Manufacturer Bently Nevada (Baker Hughes)
Country of Origin United States
Shipping Weight (Calculated) 1.0 kg
Package Dimensions (Calculated) 250 mm x 200 mm x 50 mm

Connections and Interfaces

Connection Element Function / Circuit Assignment
Coaxial Center Pin High-frequency RF signal path (dynamic measurement return)
Coaxial Outer Shield Common ground return and electromagnetic noise shielding
Connector Protector Environmental moisture and mechanical locking shield

Empirical Engineering Insights

Alternative Models & Compatibility

The 11 mm proximity probe system has a larger linear range (4.0 mm) compared to standard 8 mm probes (2.0 mm). Always match this probe with a dedicated 3300 XL 11 mm Proximitor Sensor. Intermixing an 11 mm probe with an 8 mm Proximitor sensor will cause extreme scale factor errors and render the displacement readings inaccurate.

Application Pitfalls & Engineering Notes

The FluidLoc cable specification (Option 11) is critical for installations where the machine case operates under oil mist or slight pressure differential. Non-FluidLoc cables can allow oil to bypass internal barriers via capillary action inside the cable jacket, resulting in contamination of the external junction box over long operational intervals.

Commissioning & Wiring Tips

During initial commissioning, avoid over-torquing the ClickLoc coaxial connection. Hand-tighten until a positive click is felt, then slide the connector protector sleeve firmly over the joint. To prevent interference issues, ensure that the extension cable shield is single-point grounded at the monitor rack, and not grounded inside the local junction box.

Installation Guidelines

CRITICAL WARNING

Isolate and de-energize the rotating machinery before beginning installation. Ensure zero electrical potential on any adjoining sensor circuits. Never let the probe tip make physical contact with the target face during shaft rotation, as this will immediately destroy the PPS sensor face.

1

Mounting Verification

Secure the unthreaded probe body into your specialized mounting sleeve or bracket, ensuring the face of the probe is fully parallel to the target shaft surface.

2

Mechanical Gap Setting

Carefully thread the probe inward. Use a voltmeter monitoring the Proximitor's terminal output (OUT and COM) to set the gap to the physical midpoint of the linear range (nominally -10 VDC output).

3

Securing Locknuts

Once the target electrical gap is achieved, secure the locknuts to prevent axial slip. Avoid exceeding the specified torque limits to preserve the housing threads.

4

Connecting ClickLoc Coax

Join the coaxial ClickLoc terminal to the extension cable and slide the protection sleeve over the union to secure against ingress.

Loading product navigation…

What is the primary function of the FluidLoc cable option on this probe?

The FluidLoc cable (Option 11) is engineered with internal barriers that prevent lubricating oil, water, or gases from leaking through the inside of the coaxial cable sheath into the dry connection boxes.

Can I use this 11 mm probe with an 8 mm Proximitor sensor?

No. The 11 mm probe has a larger linear range (4.0 mm) and different electrical characteristics. Mixing it with an 8 mm Proximitor sensor will cause major calibration mismatches and unusable measurements.

What is the recommended gap voltage during calibration?

For a standard 3300 XL 11 mm system, the nominal center of the linear range corresponds to -10 VDC at the Proximitor output terminal.

How do I secure the ClickLoc connector assembly?

Align the miniature coaxial connectors, press together until they lock with a click, and then slide the connector protector sleeve completely over the junction to seal it from contaminants.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...