330703-000-178-10-02-00: 3300 XL 11 mm proximity probe configuration specified with an M14 x 1.5 metric thread, 0 mm unthreaded length (Option 000), 178 mm case length (Option 178), 1.0 m total length (Option 10), and standard cable ending in a miniature coaxial ClickLoc connector (Option 02) without agency approvals (Option 00).

Unlike armored variants (such as the 330704 series) or those equipped with integrated connector protectors (Option 01), this specific configuration features a non-armored design with standard FEP-insulated cabling. It is used in Bently Nevada 3300 XL 11 mm monitoring chains to deliver reliable non-contact eddy-current displacement measurements, providing an extended linear range compared to standard 8 mm systems.

Features

  • M14 x 1.5 metric thread configuration (without armor) suitable for direct machinery mounting.
  • 0 mm unthreaded length (Option 000) allowing maximum thread engagement.
  • 178 mm case length (Option 178) designed for deep-reach installation depths.
  • 1.0 meter total probe length (Option 10) designed to interface with corresponding extension cables and Proximitor sensors.
  • Gold-plated brass ClickLoc coaxial connector (Option 02) ensuring secure, vibration-resistant coupling.
  • Standard FEP-insulated triaxial cable offering high chemical resistance and mechanical strength.
  • Polyphenylene sulfide (PPS) probe tip with patented TipLoc molding for a robust bond with the stainless steel case.

Applications

  • Axial (thrust) position measurements on steam turbines and large rotating machinery.
  • Ramp differential expansion measurements in industrial turbomachinery.
  • Rod position or rod drop measurements on reciprocating compressors.
  • Tachometer, zero speed, and Keyphasor phase reference signal generation.
  • Radial vibration and position monitoring in fluid-film bearing environments.

Ordering Information

Option / Segment Code on This SKU Description
Orderable Part Number 330703-000-178-10-02-00 3300 XL 11 mm Probe, M14 x 1.5 thread, without armor
A: Unthreaded Length Option 000 0 mm unthreaded length
B: Overall Case Length Option 178 178 mm overall case length
C: Total Length Option 10 1.0 meter (3.3 feet) total length
D: Connector and Cable Option 02 Miniature coaxial ClickLoc connector, standard cable
E: Agency Approval Option 00 Not required

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330703-000-178-10-02-00
System Compatibility 3300 XL 11 mm Proximity Transducer System
Thread Type M14 x 1.5 metric thread, unarmored
Unthreaded Length 0 mm
Case Length 178 mm
Total Probe Length 1.0 meter (3.3 feet)
Linear Range 4.0 mm (160 mils), starting at approximately 0.5 mm (20 mils) from the target
Scale Factor 3.94 V/mm (100 mV/mil) typical when paired with 3300 XL 11 mm system components
Recommended Gap Setting 2.5 mm (100 mils)
Frequency Response 0 to 8 kHz (+0, -3 dB typical)
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Cable Construction 75 ohm triaxial, fluoroethylene propylene (FEP) insulated
Connector Material Gold-plated brass ClickLoc coaxial connector
Tensile Strength 330 N (75 lb) probe case to probe lead maximum
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Operating Temperature Range -52 degC to +177 degC (-62 degF to +351 degF)
Pressure Sealing Designed to seal differential pressure between tip and case (Viton O-ring)
Recommended Torque 21.1 N-m (187 in-lb) standard; 63.3 N-m (560 in-lb) maximum rated

Installation Guidelines

Ensure the probe cable is routed away from high-voltage sources and sharp edges that could compromise the FEP insulation. Maintain the minimum bend radius of 25.4 mm (1.0 in) for all cable bends. When mounting, do not exceed the recommended installation torque of 21.1 N-m (187 in-lb) to prevent thread binding or mechanical damage to the M14 x 1.5 casing. Verify the probe-to-extension cable connections are clean and finger-tightened, followed by the standard torque procedure if matching specific housing requirements.

Compliance and Certifications

The standard 3300 XL 11 mm system is designed to comply with European CE markings for electromagnetic compatibility (RFI/EMI immunity) when properly installed. Since this specific configuration utilizes Option 00 (Agency Approval: Not required), it does not carry specific hazardous area certificates such as ATEX, IECEx, or CSA for explosive environments. Ensure appropriate installation area classifications are reviewed prior to commissioning.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330703-000-178-10-02-00 3300 XL 11 mm Proximity Probe

What does the 000-178 option indicate on the 330703-000-178-10-02-00 probe?

The 000 indicates 0 mm of unthreaded length, meaning the probe casing is fully metric threaded. The 178 specifies an overall metric case length of 178 mm, suitable for deep casing or internal mounting applications.

What target material is the 3300 XL 11 mm proximity probe calibrated to?

The probe is factory-calibrated to standard AISI 4140 steel. Calibration to alternative target materials is available upon special request.

Does the 330703-000-178-10-02-00 probe feature mechanical armor?

No, this configuration is unarmored (base model 330703). It features standard, high-durability FEP-insulated coaxial cable without stainless steel protective armor.

What is the connector type for the 330703-000-178-10-02-00 probe?

This probe features a gold-plated brass miniature coaxial ClickLoc connector (Option 02) without a connector protector. It is designed to plug directly into a standard 3300 XL 11 mm extension cable.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...