1 de 3

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

Apenas 4 item(ns) restante(s) em estoque
  • Fabricante: Bently Nevada

  • Nº do Produto: 330730-040-01-00

  • País de origem:Estados Unidos

  • Tipo de Produto: 3300 XL 11 mm Extension Cable

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 180g

  • Dimensões: 50 mm x 100 mm x 100 mm (H x W x D)

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Option 040 (4.0 m length) and Option 01 (armored coaxial cable) specify this 3300 XL 11 mm extension cable configuration — 330730-040-01-00. This 3300 XL 11 mm Extension Cable is used to bridge the physical gap between a 3300 XL 11 mm proximity probe and a 3300 XL 11 mm Proximitor sensor. It supports non-contact eddy-current displacement measurements in machinery protection systems.

Unlike non-armored standard cables (Option 02) or FluidLoc variants (Option 10), this variant is wrapped in a flexible AISI 302 stainless steel armor with an outer FEP jacket, protecting the internal coaxial line from physical abrasion and mechanical damage in demanding turbine or compressor environments. To maintain exact transducer system tuning, this 4.0 m cable must be paired with either a 1.0 m probe to form a 5.0 m system, or a 5.0 m probe to form a 9.0 m system. This Option 00 configuration is for applications that do not require specialized hazardous area approvals.

Features

  • Standard FEP insulated 75 ohm triaxial cable core with flexible AISI 302 SST protective armor.
  • FEP outer jacket over the armor to resist oil, water, and industrial chemical exposure.
  • Integrated gold-plated brass ClickLoc coaxial connectors (one male and one female) for stable signal transmission.
  • Cable length of 4.0 meters (13.1 feet), contributing to a calibrated 5.0 meter or 9.0 meter total system loop.
  • Minimum bend radius of 25.4 mm (1.0 in) simplifies installation and routing around machinery frames.

Applications

  • Steam and gas turbine rotor axial position monitoring.
  • Turbo-compressor shaft radial vibration measurement.
  • Critical rotating machinery protection within 11 mm transducer loops.
  • Mechanical monitoring installations requiring armored cable routing to prevent physical damage.

Ordering Information

Option Option Code on This SKU Description
Orderable Part Number 330730-040-01-00 3300 XL 11 mm Extension Cable
AAA - Cable Length Option 040 4.0 meters (13.1 feet)
BB - Connector and Cable Option 01 Armored cable (Flexible AISI 302 SST with FEP outer jacket)
CC - Agency Approval Option 00 Not required

Technical Specifications

Manufacturer Bently Nevada
Model / Part Number 330730-040-01-00
System Compatibility 3300 XL 11 mm Proximity Transducer System
Cable Construction 75 ohm triaxial coaxial cable, FEP insulated
Armor Protection Flexible AISI 302 SST armor with FEP outer jacket
Cable Length 4.0 m (13.1 ft)
Standard Cable O.D. 3.7 mm (0.15 in) maximum
Armored Cable O.D. 7.6 mm (0.30 in) maximum
Core DC Resistance (RCORE) 0.3 +/- 0.1 ohms
Shield/Jacket DC Resistance (RJACKET) 1.0 +/- 0.25 ohms
Extension Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Connector Material Gold-plated brass
Connector Types Miniature ClickLoc coaxial connectors (one male, one female)
Tensile Strength 270 N (60 lbs) maximum rated probe-to-cable tension
Minimum Bend Radius 25.4 mm (1.0 in)
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Relative Humidity Limit 100% condensing, non-submersible (with protected connectors)

Connections and Interfaces

Connector End Connector Type Function
Probe Connection End Miniature ClickLoc Female Coaxial Secures to the male connector of the 3300 XL 11 mm proximity probe
Sensor Connection End Miniature ClickLoc Male Coaxial Secures to the female connector of the 3300 XL 11 mm Proximitor sensor

Installation Guidelines

  • Cable Matching: The total combined length of the proximity probe lead and this extension cable must match the calibrated length (5.0 m or 9.0 m) of the paired Proximitor sensor.
  • Connector Connection: Ensure the ClickLoc connectors are clean, dry, and fully joined. Finger-tight connection is recommended, with a maximum connector-to-connector torque of 0.565 N-m (5 in-lb).
  • Protection: Apply silicone self-fusing tape or connector protectors to seal the connection from the environment. Silicone tape is not recommended if exposed directly to turbine oil.
  • Bend Radius: Avoid bending the armored cable tighter than the minimum 25.4 mm (1.0 in) radius during routing.
  • Mounting: Use appropriate cable clamps to support the armored cable along its run to prevent excessive strain on the connector ends.

Compliance and Certifications

  • EMC: EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)
  • RoHS: European Community Directive 2011/65/EU
  • FCC: Complies with Part 15 of the FCC Rules
  • Hazardous Areas: This Option 00 configuration is specified for environments where agency hazardous area approvals are not required.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-040-01-00 3300 XL 11 mm Extension Cable

What does the 330730-040-01-00 configuration represent?

The part number represents a 3300 XL 11 mm extension cable with a length of 4.0 meters (Option 040), a flexible stainless steel armor sleeve with an outer FEP jacket (Option 01), and no specialized hazardous area approvals (Option 00).

Which proximity probes are compatible with this 4.0-meter extension cable?

This cable is designed for 3300 XL 11 mm systems. It must be paired with a 1.0-meter probe to complete a 5.0-meter system loop, or a 5.0-meter probe to complete a 9.0-meter system loop.

What is the minimum bend radius for this armored cable?

The minimum bend radius is 25.4 mm (1.0 inch) with or without the stainless steel armor sleeve.

What are the electrical resistance values of this 4.0-meter extension cable?

The cable has a typical coaxial shield-to-shield jacket resistance (RJACKET) of 1.0 +/- 0.25 ohms and a center conductor core resistance (RCORE) of 0.3 +/- 0.1 ohms.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendemos mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Aceitamos devoluções de produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso site oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação, dentro da automação industrial. Ele mostra...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas em FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem às...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel fundamental na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...