BK1250 | BECKHOFF | Compact EtherCAT to K-Bus Terminal Coupler

BK1250 | BECKHOFF | Compact EtherCAT to K-Bus Terminal Coupler

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: BK1250

  • Country of origin:Alemanha

  • Product Type: Compact EtherCAT

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Product Overview

The BK1250 (BK1250) is a specialized "Bus Coupler in a terminal housing" designed to function as a bridge between the high-speed EtherCAT (E-bus) system and the standard Bus Terminal (K-bus) system. Engineered for seamless system integration, the BK1250 allows users to mix EtherCAT Terminals (ELxxxx) and standard Bus Terminals (KLxxxx) within the same terminal strand. This is particularly valuable for retrofitting existing installations or expanding systems where specialized K-bus modules are required alongside a modern EtherCAT infrastructure. By converting the EtherCAT protocol to the K-bus internal signal representation, the BK1250 enables the control of up to 64 standard Bus Terminals (expandable to 255) while maintaining the deterministic performance and diagnostic advantages of the EtherCAT network.

Technical Configuration

The BK1250 hardware architecture acts as a gateway that is physically integrated into the EtherCAT terminal block via E-bus contacts. It manages the process data exchange for up to 1024 bytes of input and 1024 bytes of output, supporting a massive density of 8,192 digital I/O points or 256 analog signals. The coupler features an internal 500 mA K-bus power supply to energize the logic of the attached Bus Terminals. Configuration is highly flexible, allowing engineers to set up the module via the KS2000 software or directly through EtherCAT using ADS (Automation Device Specification) commands. The compact 12 mm housing includes signal LEDs for real-time status monitoring of power, K-bus communication, and EtherCAT link activity.

Technical Specifications

Feature Specification
Model BK1250
Brand BECKHOFF
Origin Germany
Protocol EtherCAT
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Data Transfer Rate 100 Mbit/s
K-bus Current Supply 500 mA
Max. Process Data 1024 Byte Input / 1024 Byte Output
Power Supply 24 VDC (-15 percent / +20 percent)
Electrical Isolation 500 V (power contact / supply voltage / Ethernet)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating Temperature -25 to +60 Celsius
Weight approx. 55 g

Technical FAQs

Can I place the BK1250 anywhere in an EtherCAT terminal strand?

Yes, the BK1250 is designed to be installed as a standard terminal within an EtherCAT block. It bridges the communication from that point forward to any following KLxxxx (K-bus) terminals.

What happens if the total current draw of my K-bus terminals exceeds 500 mA?

The BK1250 provides 500 mA for the K-bus logic. If your terminal configuration requires more current, you must insert a KL9400 or KL9410 power supply terminal into the K-bus segment to refresh the logic power.

Is software configuration required to recognize the attached Bus Terminals?

The BK1250 automatically scans the attached K-bus terminals upon startup. However, in the TwinCAT System Manager, you must manually append the KL terminals to the BK1250 device to define the process image mapping correctly.


Engineering & Installation Guide

  • System Migration Strategy: Use the BK1250 to leverage your existing inventory of KL-series terminals while upgrading your main controller to an EtherCAT-capable Embedded PC. This approach significantly reduces hardware costs and wiring labor during system overhauls.

  • Power Contact Management: The coupler passes through the 24 VDC power contacts (up to 10 A). Ensure that the power supply connected to the BK1250 is sufficient for both the K-bus logic and the field power requirements of the attached digital/analog modules.

  • Wiring Precision: The module features spring-actuation terminals. For high-vibration industrial environments, always use ferrules for stranded wires (0.14 to 1.5 mm²) to ensure a gas-tight connection. A stripping length of 8 to 9 mm is required to prevent contact issues or internal short circuits.

  • K-Bus Extension: For large-scale applications requiring more than 64 terminals, utilize K-bus extension terminals (KL9020/KL9050) in conjunction with the BK1250 to manage up to the maximum limit of 255 modules.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Branco
Country of origin
Alemanha

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...