1 de 3

GE DS2020DACAG2 EX2100 AC-DC Power Conversion Assembly

GE DS2020DACAG2 EX2100 AC-DC Power Conversion Assembly

Only 4 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: DS2020DACAG2

  • Country of origin:Estados Unidos

  • Product Type: AC-DC Power Conversion Assembly

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 21950g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Description

The DS2020DACAG2 operates as a ruggedized AC to DC power conversion assembly designed for integration within EX2100 excitation systems and Mark VIe control networks. This power supply module supplies regulated local energy to essential distribution architectures, effectively extending systemic control ride-through capabilities during line source failures or operation within completely battery-less configurations.

The structural circuit path of the DS2020DACAG2 executes rectification of alternative source feeds into structured direct current bus rails. Operating from a dual-tap 115 VAC or 230 VAC line entry, the module delivers an output potential rated at 126 VDC with a maximum delivery boundary of 9.5 ADC under individual assembly usage. This rectified DC line couples to concurrent system energy feeds through an on-board diode network to build a common distribution bus, directly feeding secondary controller blocks, core module sectors, and active gate pulse amplifier cards. The conversion topology utilizes heavy-duty electrolytic storage capacitors to maintain ripple filtering, accompanied by dedicated diagnostic LED indicators arranged at downstream modules (such as EPDM, EGPA, EXTV, and EPBP) to verify consistent power rail health. For expanded system loads, multiple units can be coupled in parallel configurations via a standardized 12-position connector interface to boost aggregate loop outputs to 16.5A DC.

Features

  • Dual-Voltage Input Conversion: Rectifies standard 115 VAC or 230 VAC utility inputs into a stabilized 126 VDC configuration loop.
  • Parallel Core Scaling: Supports dual-module parallel load sharing across a shared bus to increment total output delivery up to 16.5A DC.
  • Integrated Ride-Through Buffering: Provides localized capacitive hold-up capacity to secure system control execution parameters over temporary line voltage drops.
  • Diode-Coupled Bus Isolation: Employs built-in steering diodes to seamlessly tie converted DC current with alternative backup battery rails.

Applications

  • EX2100 Excitation Bus Power: Delivers continuous rectified bus power to gate pulse amplifier boards and excitation distribution racks.
  • Mark VIe Battery-Less Controller Feeds: Main power conversion assembly deployed in turbine generator infrastructure missing static battery storage banks.
  • Industrial DC Distribution Maintenance: Used as a drop-in, fully backward-compatible replacement for obsolete Group 1 (DS2020DACAG1) modules.

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model DS2020DACAG2
Product Series EX2100 Excitation Series / Mark VIe System
Module Type AC-DC Power Conversion Assembly
Functional Acronym DACA
Power Conversion Parameters 115/230 VAC input to 126 VDC output
Output Power Rating 1000 W
Maximum Output Current (Single) 9.5 ADC
Maximum Output Current (Parallel) 16.5 ADC
Capacitor Configuration Wear-replaceable Electrolytic Capacitors
Operating Temperature -22 to +140 degF (-30 to +60 degC) via free convection
Operating Humidity Bounds 5 to 95%, non-condensing
Calculated Life Expectancy 100 years at ambient temp of 68 degF (20 degC)
PCB Coating Profile Normal style surface coating
Replaces Model DS2020DACAG1 (Group 1)
Product Weight 48.39 lbs (21.95 kg)

Connections/Interfaces

Connector Identifier Terminal Layout Function
JZ Connector 12-Position Modular Block Integrated input path for raw AC entry and output pathway for rectified DC loops

Installation Guidelines

  • Bus Line De-energization: Verify total isolation and zero potential on all source input wires and parallel battery loops before attempting hardware replacement.
  • ESD Shielding Protocol: Installation engineers must stay attached to an approved, fully grounded anti-static wrist strap to avert dielectric shock to the inner circuit components.
  • Parallel Voltage Matching Requirements: If operating dual conversion assemblies in a parallel network, both blocks must hook into the identical AC source link to secure identical source input potentials.
  • Harness Interconnection Setup: When wiring the conversion assembly alongside an IS2020JPDF module, lock the specialized wiring harness firmly between the JPDF and JPDB terminals.

Existem diferenças de design entre o DS2020DACAG1 e o DS2020DACAG2?

Praticamente não há diferenças funcionais entre os dois modelos. O DS2020DACAG2 serve como uma substituição direta e totalmente compatível com versões anteriores do módulo DS2020DACAG1.

É possível conectar duas unidades em paralelo a fontes de alimentação CA separadas?

Não. Ao operar dois conjuntos em paralelo para aumentar a corrente de saída para 16,5A, eles devem estar conectados à mesma fonte de entrada CA para manter tensões de entrada equilibradas.

Como a temperatura ambiente extrema de operação altera a vida útil esperada do módulo?

Embora a expectativa de vida básica seja de 100 anos a 20 °C, operar continuamente a uma temperatura ambiente elevada de 65 °C degrada os capacitores eletrolíticos internos, exigindo a substituição do módulo aproximadamente a cada cinco anos.

Quais medições de tensão nominal devem ser verificadas em uma configuração de barramento CC acoplado e aterrado?

Quando o módulo de conversão está corretamente acoplado por diodo e aterrado, as verificações de tensão nominal entre os trilhos do barramento devem registrar +62,5 VCC e -62,5 VCC em relação ao terra.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Pontos Prata
Country of origin
Estados Unidos

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...