The IC695NIU001 functions as a high-performance Ethernet Network Interface Unit (NIU) within the PACSystems RX3i control platform series. This dual-width communication module is engineered to enable the remote deployment and automatic execution of standard PACSystems RX3i and Series 90-30 I/O modules across a distributed Ethernet network architecture. Once established via user configuration, data exchange operates completely automatically, allowing system control to be driven by any master device capable of handling Ethernet Global Data (EGD) transfers. The IC695NIU001 continuously delivers diagnostic status markers back to the primary controller during every single data exchange, allowing application logic to dynamically monitor link health and issue real-time commands to the remote chassis. It utilizes basic Ethernet modules (such as the IC695ETM001) mounted in an RX3i Universal Backplane to establish network pathways, supporting secure SRTP TCP/IP communications and seamless integration with high-availability redundancy controllers.

Features

  • Coordinates fully automatic, high-speed remote I/O data transfers over network lines via Ethernet Global Data (EGD) services.
  • Provides 20 Kbytes of selectable local logic memory space supporting standard programming languages (excluding C programming).
  • Embeds 10 Mbytes of non-volatile flash user memory for secure local application data and hardware configuration backup.
  • Features an integrated, battery-backed calendar clock to preserve precise system time logs during host chassis power outages.
  • Incorporates two dedicated onboard serial communication ports (one RS-232 COM1 port and one RS-485 COM2 port) for local peripheral or programmer connections.
  • Supports execution of unique COMMREQ commands issued via Ethernet by C application blocks running in a master PACSystems RX7i or RX3i controller.

Applications

  • Distributed Remote I/O Networks: Extending and centralizing remote PACSystems RX3i and Series 90-30 I/O drops across expansive plant locations.
  • High-Speed Process Synchronization: Utilizing Ethernet Global Data highways to manage fast data exchanges in multi-node continuous manufacturing operations.
  • Infrastructure Redundancy Frameworks: Deploying automated fieldbus interfaces alongside redundancy controllers in mission-critical water, power, or oil and gas utilities.

Technical Specifications

Parameter Value
Manufacturer GE Fanuc (GE Intelligent Platforms)
Model Number IC695NIU001
Series PACSystems RX3i
Product Type Ethernet Network Interface Unit
Local Logic Memory 20 Kbytes (C programming not supported)
Non-Volatile Flash Memory 10 Mbytes
Onboard Serial Ports 1 x RS-232 (COM1), 1 x RS-485 (COM2)
Serial Protocols Supported Modbus RTU Slave, SNP Slave, Serial I/O, Message Mode
Data Exchange Capacity Up to 1300 bytes Input / 1300 bytes Output per exchange
Recommended Battery Pack 3-cell Lithium Battery Pack (IC698ACC701)
Compatible Programming Software Machine Edition Logic Developer version 5.51 or later
Backplane Slot Occupation Dual-width module (occupies 2 standard slots)
Weight 0.55 KG
Dimensions (W x H x D) 35 mm x 140 mm x 135 mm

 

Connections/Interfaces

Port Designation Physical Interface and Function
COM1 (Port 1) 9-pin female D-sub connector, RS-232 signaling; supports WinLoader firmware updates and direct programmer linkages
COM2 (Port 2) 15-pin female D-sub connector, RS-485 signaling; accepts RS-485 to RS-232 adapter (IC690ACC901) connections

 

Installation Guidelines

  • Verify that all incoming electrical power to the RX3i Universal Backplane is completely turned off before inserting or removing the network hardware.
  • Position the unit firmly inside a primary Universal Backplane (IC695CHS0xx) slot 0. As a dual-width module, it occupies two physical slots (typically slots 2 and 3). Do not place it in the rightmost slot of the backplane, as this slot lacks a physical securing latch.
  • Upon turning on rack power and completing internal system initialization, ensure that the front-panel NIU OK LED shines steady green, while the NIU SCANNING I/O and EN LEDs remain unlit until active scanning is configured.
  • To maximize the operational shelf life of the external lithium cell, do not attach the backup battery connector until after the module has been plugged in and powered up for the first time.
  • When executing field maintenance or replacing an exhausted battery, always leave rack power turned on; inserting a new battery pack while the system is completely powered down can trigger a startup fault during the next power cycle.

Compliance and Certifications

  • CSA: Certified by the Canadian Standards Association for safe deployment as industrial process control equipment within ordinary, non-hazardous locations.
  • Factory Mutual (FM): Approved as nonincendive equipment intended for use in Class I, Division 2, Groups A, B, C, and D hazardous environments.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Fanuc PACSystems RX3i IC695NIU001 Ethernet Network Interface Unit

How does the network interface unit exchange data with the central controller?

The device exchanges data over an Ethernet network using Ethernet Global Data (EGD) services. It is typically configured with two individual exchanges: one to receive outputs from the master controller and another to send local inputs back.

What is the correct procedure if the device fails to boot after a battery change error?

If the module fails to power up because a new battery was connected while the rack was entirely powered down, disconnect the battery, perform a full power cycle on the chassis, and then reattach the battery while the system is powered on.

Which industrial fieldbus protocols are supported by the onboard serial ports?

The embedded serial channels natively support Modbus RTU Slave, SNP Slave, standard Serial I/O interface configurations, and raw Message Mode communications.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Preto
Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...