1 de 3

GE Multilin UR-9EH Central Processing Unit Module

GE Multilin UR-9EH Central Processing Unit Module

Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-9EH

  • Country of origin:Estados Unidos

  • Product Type: CPU Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 660g

  • Dimensions: 16,3 cm x 4,2 cm x 21 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Description

The UR-9EH is a high-performance Central Processing Unit (CPU) Module engineered for the GE Vernova Multilin Universal Relay (UR) Series protection platforms. It serves as the primary computational hub of the relay, delivering the core infrastructure required to execute mathematical protective algorithms, logic gate configurations, latch controls, and sub-millisecond timing operations.

Classified under the advanced 9E–9S series CPU architecture, the UR-9EH provides a standardized pathway to upgrade or swap legacy, aging, or non-functional control cards inside existing UR-chassis systems. The module features integrated Ethernet Port interfaces to maintain rapid, deterministic communication across substation control levels. By natively supporting robust communication topologies alongside advanced internal diagnostic subsystems, it ensures full system compatibility with critical protective relay configurations like the B30, L90, and M60.

Features

  • Resource Optimization via Server Scanning Control: Built-in "Server Scanning" functionality can be disabled within the firmware environment to eliminate unnecessary IEC 61850 processing overhead, maximizing CPU computing availability for core protection loops.
  • Plug and Play Backplane Integration: Automatically provisions baseline data parameters, core application logic, and physical communication ports immediately upon seating into the UR backplane.
  • Advanced Networking Integration: Features integrated Ethernet ports supporting redundant communication topologies and high-accuracy time synchronization protocols.
  • Dual Configuration Mediums: Enables full parameter modification and diagnostic tracking using either the front keypad interface or remote software environments.

Applications

  • Central processing logic upgrades for existing Multilin Universal Relays (B30, L90, M60, etc.) 
  • Substation automation networks utilizing IEC 61850 architectures 
  • Replacement of faulty or degraded control cards in mission-critical protection networks 

Technical Specifications

Parameter PDF Specification & Details
Manufacturer GE Vernova (Grid Solutions)
Module Category Central Processing Unit (CPU) Module
Architecture Family 9E–9S series CPU architecture 
Chassis Compatibility Multilin Universal Relay Series (e.g., B30, L90, M60)
Dimensions 6.5" L x 6.0" W x 2.5" H (approx. 16.5 x 15.2 x 6.4 cm)
Weight ~1 lb 10 oz (0.74 kg)
Power Consumption Nominal 15W
Operating Temp -10 Celsius to +55 Celsius
Storage Temp -40 Celsius to +85 Celsius
Primary Interface Ethernet Port Integration
Protocols Supported IEC 61850 (Ed. 1 & Ed. 2), SNTP, Redundant topologies
Configuration Tools Front Keypad/Faceplate or EnerVista UR Setup Software

Installation Guidelines

⚠️ CRITICAL REPLACEMENT RULE: General Electric dictates strict hardware generation pairing rules. A new-generation CPU module like the UR-9EH must only be paired with new-generation CT/VT modules inside the chassis. Mixing older-generation analog sensing cards with newer 9E series processors triggers immediate HARDWARE MISMATCH or DSP ERROR locks on the faceplate. Always verify the manufacturing age of the surviving chassis modules before seating the card.

Pre-Installation Protocols

  • Fully isolate the Universal Relay chassis from all high-voltage sub-transmission or distribution lines.
  • Disconnect all secondary auxiliary power supply feeds.
  • Wear a grounded Electrostatic Discharge (ESD) wrist strap to avoid destroying internal microprocessors.
  • Back up your existing relay configuration files (.urs files) via the EnerVista software through network ports if the older CPU remains partially operational.

Removing the Defunct Module

  1. Unfasten the module retaining screws located on the top and bottom exterior of the CPU slot (typically Slot F in most standard UR frameworks).
  2. Pull the module extraction handles outward smoothly to separate the card from the backplane connectors.

Inserting the UR-9EH

  1. Align the plastic guides on the UR-9EH circuit card with the open tracking grooves inside the vacant chassis slot.
  2. Slide the module straight into the bay until the faceplate sits completely flush with the surrounding frame.
  3. Push firmly on the edges to guarantee that the multi-pin rear connector is completely locked into the backplane.
  4. Fasten and tighten the top and bottom retaining screws to secure physical ground contact. Note: CPU modules rely on standard mechanical chassis grounding and do not require independent dedicated surge ground wires.

Post-Installation Boot & Provisioning

  1. Apply auxiliary power back onto the UR chassis power supply module.
  2. Observe the self-test routing on the front panel liquid crystal display, checking that no HARDWARE MISMATCH, DSP ERROR, or WRONG TRANSCEIVER flags are thrown.
  3. Attach an Ethernet or serial cable to connect your PC running the EnerVista platform to upload the application-specific firmware parameters and protection profiles.

FAQ

What is the significance of the Server Scanning feature on this module? 

The integrated "Server Scanning" feature can be intentionally disabled inside the firmware configuration. This action frees up significant internal processor overhead for substation deployment layouts that do not utilize or require full IEC 61850 client/server functionality, reallocating resources to other primary computations.

What happens if I pair the UR-9EH with older analog sensing cards?

 Attempting to pair this 9E-series processor with legacy-generation CT/VT sensing cards causes an immediate architecture conflict. The host relay will trigger a continuous hardware mismatch or DSP error lock on the front screen, suspending protection operations until compatible hardware generations are aligned.

Does this CPU module require a dedicated external grounding wire? 

No, independent dedicated surge ground wires are not required for this module. The unit achieves adequate grounding entirely through mechanical chassis grounding contact points once the top and bottom faceplate retaining screws are tightened flush against the surrounding frame.

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Preto
Country of origin
Estados Unidos

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...