Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-9GH

  • Country of origin:Estados Unidos

  • Product Type: CPU Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 177,0 mm x 482,6 mm x 234,0 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Description

The GE Multilin UR-9GH centrally processes protection logic, communication tasks, and system diagnostics as a core processing hub within the Universal Relay (UR) platform. Specifically engineered as a replacement component for vertical hardware configurations, this CPU Module delivers coordinated calculation capacity to manage extensive electrical substation protection automation. The UR-9GH integrates dedicated serial and network communication cards to route plant parameters via industrial fieldbuses, incorporating a 9G communication architecture that establishes simultaneous links over optical networks and legacy multidrop copper lines. Additionally, it features an integrated 1A / 5A ground current transformer secondary input channel (1A/5A Ground CT) directly on the processing unit assembly. This specialized analog input enables the module to acquire local neutral or residual currents for critical zero-sequence overcurrent protection calculations, optimizing control response and field data routing across high-voltage and medium-voltage power distribution assets.

Features

  • Coordinates centralized mathematical calculation routines and real-time protection algorithms within UR-series chassis.
  • Integrates a hardware-level 1 A / 5 A ground current transformer interface directly into the controller assembly.
  • Equipped with a 9G communication configuration featuring independent dual-media network transceivers.
  • Runs standard Modbus TCP/IP and DNP 3.0 automation protocols simultaneously for SCADA and DCS master interfaces.
  • Supports high-speed oscillography capture, detailed sequence-of-events logging, and precision metering.
  • Designed specifically to match vertical mechanical orientation relay units for drop-in component replacement.

Applications

  • Substation automation and supervisory control data acquisition (SCADA) systems.
  • Electrical fault diagnostics, localized ground fault monitoring, and zero-sequence current tracking.
  • Power generation utility networks requiring concurrent dual-protocol Ethernet and serial communications.
  • Retrofit or maintenance replacement within existing UR series vertical protection systems.

Ordering Information

Code / Suffix Selection Component Description
UR-9GH Main Replacement Part Number for Vertical Units
UR UR Series Platform Designation
9G CPU Communication Type: RS485 and 10Base-F Interface Card
H CT Input Option: 1A / 5A Ground Current Transformer

Technical Specifications

Parameter Category Specification Details
Manufacturer GE Multilin (General Electric)
Country of Origin Canada
Module Type Central Processing Unit (CPU) Module
Orientation Vertical mounting configurations
Communication Profile Type 9G Architecture
COM1 Media Ports 10Base-F (Fiber) and 10Base-T (Copper Ethernet)
COM2 Media Port RS485 (Serial)
Embedded Protocols Modbus TCP/IP, DNP 3.0
Analog Ground Input Dual-rated 1 A / 5 A secondary current transformer
Dimensions Standard full-height UR Series plug-in card profile

Connections/Interfaces

Connection Port Function / Protocol Support
COM1 (10Base-F) Fiber optic network port running Modbus TCP/IP or DNP 3.0 over Ethernet.
COM1 (10Base-T) Twisted-pair RJ45 copper network port for local engineering workstation deployment.
COM2 (RS485) Balanced differential multi-drop serial terminal for legacy RTU communication.
Ground CT Terminals Rear screw terminals allocated for direct connection to external 1A or 5A secondary ground CT wiring loops.

Installation Guidelines

  • Control Power Safety: Completely isolate and disconnect the control power source feeding the UR rack before extracting or executing an upgrade with the CPU card.
  • Orientation Verification: Confirm the replacement unit matches the mechanical framework of the rack; this module is intended exclusively for vertical assembly housings.
  • ESD Mitigation: Technicians must connect an anti-static wrist strap to a verified system ground point before handling the circuit boards of the controller.
  • Firmware Configuration: After seating the module, check that the existing relay setting files and firmware revision profiles align with the new 9G configuration to avoid processing
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-9GH UR Series CPU Module

正在加载 PDF,请稍候…

Quais protocolos são processados nativamente pela interface COM1 neste módulo?

A interface COM1 utiliza a configuração de hardware 9G para gerenciar comunicações Modbus TCP/IP e DNP 3.0 simultaneamente em links de fibra e cobre.

Este cartão CPU específico pode ser usado como substituição direta em configurações horizontais de chassis UR?

Não. Este módulo é indexado e estruturado especificamente sob códigos de pedido destinados a unidades de substituição vertical e estruturas de hardware verticais.

A entrada do transformador de corrente de aterramento requer escalonamento de software separado para operação em 1A e 5A?

Sim. O loop de hardware aceita configurações secundárias de 1 A e 5 A, mas a classificação da entrada deve ser explicitamente designada nos parâmetros de configuração do software do relé.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Preto
Country of origin
Estados Unidos
Power source
Alimentado por energia AC

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...