1 de 3

GE UR5CH Multilin UR Transducer I/O Module | Universal Relay Series

GE UR5CH Multilin UR Transducer I/O Module | Universal Relay Series

Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: UR-5CH

  • Country of origin:Estados Unidos

  • Product Type: Transducer I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 360g

  • Dimensions: 8,2 cm x 12,2 cm x 6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantidade
Ver informações completas

Product Overview

The GE UR5CH is a specialized Transducer Input/Output module designed for the Multilin Universal Relay (UR) platform. This module serves as the critical bridge between the digital protection environment and external analog equipment, allowing the relay to interface with standard industrial transducers that provide d-c milliamp (mA) or d-c voltage (V) signals.

Typically utilized in complex substation automation and industrial power monitoring, the UR5CH enables the relay to monitor non-electrical parameters (such as temperature, pressure, or vibration via external transducers) or to output control signals to analog gauges and PLC systems. By integrating these "Transducer-style" signals directly into the UR frame, the UR5CH eliminates the need for separate data acquisition hardware, centralizing all protection, control, and monitoring logic within a single, ruggedized chassis.


Technical Configuration

The UR5CH is a hardware-specific module designed to occupy a standard I/O slot (Slots 2 through 7) within a UR series relay (e.g., B30, C60, G60, or T60).

  • Channel Density: Features 8 independent channels that can be factory-configured or software-selected for input or output functions.

  • Signal Versatility: Supports standard industrial signal ranges, including 4-20 mA, 0-1 mA, and various d-c voltage levels (e.g., -10V to +10V).

  • High-Resolution Conversion: Employs high-precision A/D (Analog-to-Digital) and D/A (Digital-to-Analog) converters to ensure signal accuracy is maintained for sensitive control loops.

  • FlexLogic™ Integration: All transducer inputs can be used as operands within the GE FlexLogic™ engine, allowing the relay to trigger alarms or trips based on analog thresholds (e.g., "Trip if transformer oil temperature transducer exceeds 16mA").


Technical Specifications

Parameter Specification Details
Platform GE Multilin Universal Relay (UR)
Module Type Transducer Input/Output (I/O)
Number of Channels 8 Channels
Input Ranges ±1 mA, 0-1 mA, 4-20 mA, ±10 V, 0-10 V (Option dependent)
Output Ranges 4-20 mA, 0-20 mA (Option dependent)
Accuracy ±0.1% of Full Scale at 25°C
Isolation 2 kV Channel-to-Ground / 100 V Channel-to-Channel
Update Rate 100 ms (Typical for all channels)

Engineering Installation Guide

Reliable transducer monitoring requires meticulous attention to wiring and shielding to prevent signal "drift" or noise interference.

Wiring and Noise Mitigation

Because transducer signals are low-energy d-c levels, they are highly susceptible to electromagnetic interference. Always use twisted-pair, shielded cables for all transducer runs. The shield should be grounded only at the relay end to prevent ground loops. Avoid routing transducer cables parallel to high-voltage AC busbars or motor leads; if crossing is necessary, cross at a 90-degree angle.

Module Seating

Before installing the UR5CH, de-energize the UR relay power supply. Slide the module into its designated slot and ensure the ejector handles click into the locked position. Once powered up, use the EnerVista UR Setup software to configure the "Transducer Range" and "Scale Factor" for each channel to match the physical transducer's output.


Engineering Advantages

The UR5CH module significantly enhances the "Universal" nature of the Multilin UR platform. By supporting both inputs and outputs, it allows the relay to perform Analog Re-transmission. For example, the relay can measure a high-voltage primary current through its CT inputs and then use the UR5CH to output a proportional 4-20mA signal to a legacy SCADA RTU or a local panel meter.

Furthermore, the module includes comprehensive self-diagnostics. If a transducer wire is broken (Open Circuit) or shorted, the UR5CH detects the out-of-range signal and can trigger a "Module Not OK" alarm. This prevents the control system from making decisions based on "frozen" or erroneous data, a common failure mode in traditional analog systems.


Technical FAQs

Q1: Can I mix voltage and current inputs on the same UR5CH module?

A1: This depends on the specific ordering code of your UR5CH module. Some versions are "Current Only" or "Voltage Only," while others are hardware-configured at the factory for a specific mix. Check the module's side label for the specific channel mapping.

Q2: How do I calibrate a channel if the reading is slightly off?

A2: The UR5CH is factory-calibrated. However, you can apply a "User Offset" and "Gain" through the EnerVista software to compensate for resistance losses in long field cable runs, ensuring the value displayed on the relay HMI matches the physical measurement at the sensor.

Q3: Is the UR5CH suitable for high-speed protection trips?

A3: Transducer signals generally have an update rate of approximately 100ms. While excellent for monitoring and slow-acting control (like cooling fans or tap changers), they are not intended for high-speed "Instantaneous" electrical protection, which should be handled by the relay's CT/VT modules.

Q4: What happens to the outputs if the relay loses power?

A4: Upon loss of power, the D/A converters will de-energize, and the d-c output signals will drop to zero. Ensure your downstream control logic (in the PLC or DCS) is programmed to recognize a 0mA signal as a "Fail-Safe" or "Loss of Signal" condition.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...

Programando Ciclos de Movimento de Eixo Único em um Servo Drive CMZ

Este tutorial examina como a funcionalidade PLC integrada dentro de um servo drive CMZ SBD pode executar programas de movimento autônomos, incluindo lógica de referência, controle de posição e...

Configuração de Controle de Movimento de Eixo Único com Drives Servo CMZ

Este tutorial explora a comissionamento de um sistema de movimento servo de eixo único usando um drive CMZ SBD, abrangendo a configuração de hardware, escala do eixo, configuração de homing e...