1 de 3

General Electric Mark VIe IS230TRLSH2B Relay Output Module

General Electric Mark VIe IS230TRLSH2B Relay Output Module

Apenas 7 item(ns) restante(s) em estoque
  • Fabricante: General Electric

  • Nº do Produto: IS230TRLSH2B

  • País de origem:Estados Unidos

  • Tipo de Produto: Relay Output Module

  • Código de barras: 8537101190

  • Pagamento: T/T, Western Union

  • Peso: 2920g

  • Dimensões: 34cm x 22.5cm x 11.5cm

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

The General Electric IS230TRLSH2B is a specialized relay output terminal board module designed for the Mark VIe control system platform. This Relay Output Module interfaces with control processors to safely drive field solenoids, control valves, motor starters, and external interlock circuits across heavy industrial environments. Operating as a component within the distributed control architecture, it receives digital commands from the system controller and converts them into physical, isolated dry contact closures or voltage switching states. It is engineered specifically for system compatibility within large-scale utility and turbine control frameworks, providing robust physical separation between low-voltage microelectronic control loops and high-voltage field execution circuitry.

Features

  • Built for reliable physical and electrical galvanic isolation within the modular framework
  • Designed to accept high-speed logic state signals from upstream control layers
  • Equipped with rugged on-board relays configured for continuous operational duty
  • Features terminal block junctions directly on the board assembly for secure field loop routing
  • Integrates seamlessly with multi-channel architecture to minimize cabinet hardware footprints

Applications

  • Distributed Control Systems (DCS) for gas, steam, and hydro turbine regulation
  • Solenoid valve control and auxiliary pump startup staging
  • Safety interlock processing and remote equipment trip circuits
  • Heavy industrial power plant, manufacturing, and critical system infrastructure automation

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Model Designation IS230TRLSH2B
System Series Mark VIe Control System
Module Type Relay Output Terminal Board Module
Country of Origin USA
Channel Configuration Multi-channel dedicated relay outputs
Enclosure / Mounting Panel or base assembly carrier layout
Operating Temperature 0 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Humidity Constraints 5% to 95% non-condensing relative humidity

Connections/Interfaces

Terminal Assignment Function
Screw Terminals (Field Side) Field device loop connections (Form-C or Form-A contacts)
I/O Pack Connector High-density multi-pin communication bridge to the primary controller
Shield Terminals Shield drain wire termination ground points for EMI containment

Installation Guidelines

Cabinet Orientation & Mounting

Secure the module onto its designated backplate or carrier structure inside the control cabinet. Ensure the mounting fasteners are fully tightened to ground the underlying metal chassis panel and isolate the board from excessive high-frequency structural vibration.

Cable Shielding & Routing

Route all digital signal cables separate from heavy AC power lines to protect against inductive cross-coupling and electrical noise. Terminate field wire shields only at the specified system ground point on the board frame.

Connection Torques

When tightening the terminal block screws for field loops, torque them according to standard industrial terminal specifications to prevent loose contact junctions or intermittent continuity dropouts during thermal cycling.

Loading product navigation…

What primary function does this board perform in the system?

The module operates as a relay output interface, receiving electronic logic commands from the controller and activating physical relay contacts to switch external field loads safely.

How should shield drain wires be terminated on this board?

Shield drain wires must be connected directly to the dedicated shield termination points provided on the module frame to secure effective path-to-ground noise mitigation.

What is the recommended storage temperature range for this module?

The safe storage temperature limit for this module spans from -40 degC to +85 degC under non-condensing atmospheric conditions.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Color pattern
Preto
Country of origin
Estados Unidos
Power source
Energia CC

Produtos Visualizados Recentemente

Conhecimento técnico

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Transformaram a Mineração Subterrânea

Desde compressores CC acionados por corda até carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como...