1 de 1

Honeywell 900A01-0202 HC900 Analog Input Module

Honeywell 900A01-0202 HC900 Analog Input Module

Apenas 8 item(ns) restante(s) em estoque
  • Fabricante: Honeywell

  • Nº do Produto: 900A01-0202

  • País de origem:Estados Unidos

  • Tipo de Produto: Analog Input Modules

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Processing multi-channel analog signals is simplified using the Honeywell 900A01-0202, a high-performance, 8-channel isolated analog input module designed for the HC900 process controller platform. This module allows direct connection to a wide range of industrial sensors, featuring universal channel configuration to minimize hardware footprint and simplify system design. Each of the eight channels can be individually programmed to accept different signal types, including thermocouples, RTDs, voltage, current, resistance, and slidewires, providing high application flexibility in demanding process environments.

The Honeywell 900A01-0202 features robust galvanic isolation to prevent ground loop currents from degrading signal integrity. With channel-to-channel and channel-to-logic isolation, the module maintains stable operation and high measurement accuracy even in electrically noisy industrial settings. Integrated diagnostics, such as thermocouple break detection via current pulse, ensure rapid troubleshooting and reduced system downtime.

Features

  • Eight independent, galvanically isolated analog input channels.
  • Universal input support including mV, V, mA, RTD, Thermocouple, Ohms, and Slidewire.
  • Robust isolation: 400 VDC point-to-point and 1000 VDC input-to-logic.
  • High-efficiency noise rejection with >130dB common mode rejection at 120VAC.
  • Active sensor diagnostics with automatic thermocouple break detection.
  • RTD inputs isolated in pairs for optimal signal processing and cabling efficiency.

Applications

  • Thermal processing and industrial furnace monitoring.
  • Oil and gas refining and pipeline monitoring.
  • Chemical processing and reactor temperature tracking.
  • Power generation plant parameter monitoring.
  • Water and wastewater treatment facility automation.

Technical Specifications

Manufacturer Honeywell
Part Number / Model 900A01-0202
Series HC900 Control System
Module Type Analog Input Module
Number of Channels 8 (isolated)
Input Configurations mV, V, T/C, RTD, Ohms, mA, Slidewire (configurable per channel)
Input Impedance (T/C and mV) 10 megohms
Input Impedance (Volts) >1 megohm
Input Impedance (mA) 250 ohms
Galvanic Isolation (Point-to-Point) 400 VDC
Galvanic Isolation (To Logic) 1000 VDC
Series Mode Noise Rejection >60dB
Common Mode Noise Rejection >130dB at 120VAC
Over-Range Limit (Linear/Volts) +/- 10%
Over-Range Limit (Non-Linear/TC, RTD) +/- 1%
Sensor Break Detection Thermocouple break detection via current pulse
Shipping Weight 2 kg

Connections and Interfaces

Connection Type Specification / Layout
RTD Wiring configuration Isolated in pairs (IRTD is common to two inputs)
Thermocouple Inputs Cold junction compensation; maximum 100 Ohms/Leg
RTD Compatibility PT100 3-wire (40 ohms balanced max), 100/500/1000 RTD (100 Ohms/Leg), 10 Ohm Cu (10 Ohms/Leg)
Slidewire Range 100 to 6,500 Ohms (10% of total resistance/leg)

Installation Guidelines

  • Mounting: Ensure the module is securely seated in the HC900 rack chassis slot and the module retaining screws are fully tightened.
  • Wiring: Route low-voltage analog input signal cables away from high-voltage AC power distribution wiring to prevent electromagnetic coupling.
  • Shielding: Use shielded twisted-pair cabling for all sensor connections. Connect shields to the chassis ground bar at the controller end only.
  • Thermal Management: Maintain recommended clearance spaces around the rack assembly to ensure natural convection cooling matches environmental specifications.
Loading product navigation…

What sensor types can be connected to the Honeywell 900A01-0202 module?

The Honeywell 900A01-0202 is a universal analog input module that supports thermocouples, RTDs (including PT100), millivolt (mV) signals, standard DC voltage (V), DC current (mA), resistance (Ohms), and slidewire inputs.

What isolation levels does the 900A01-0202 input module provide?

The module provides galvanic isolation of 400 VDC point-to-point (channel-to-channel) and 1000 VDC isolation from the input channels to the controller's logic circuit. Note that RTD inputs are isolated in pairs.

How does the module handle sensor diagnostics, such as broken thermocouple wires?

The 900A01-0202 module uses an active current pulse method to perform real-time sensor break detection on thermocouple input channels.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...