1 de 1

Omron G9SX-ADA222-T150-RC G9SX Flexible Safety Unit

Omron G9SX-ADA222-T150-RC G9SX Flexible Safety Unit

Apenas 6 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: G9SX-ADA222-T150-RC

  • País de origem:Japão

  • Tipo de Produto: Flexible Safety Units

  • Pagamento: T/T, Western Union

  • Peso: 200g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Designed for high-performance machine safety management, the Omron G9SX-ADA222-T150-RC serves as an advanced safety controller within the Omron G9SX series. This flexible safety unit provides reliable control of safety circuits, offering both instantaneous and OFF-delayed safety outputs to accommodate complex deceleration and stopping requirements in industrial machinery. Equipped with spring-cage terminal blocks, it ensures secure, vibration-resistant connections in demanding production environments.

The unit features solid-state outputs that minimize mechanical wear and extend operational life. By providing separate pathways for instantaneous shutdown and timed deceleration, the module supports sophisticated safety logic and sequencing. It functions as an advanced main unit that can be easily integrated into distributed safety control networks.

Features

  • Advanced safety logic unit with multi-output configuration.
  • Two instantaneous safety outputs and two OFF-delayed safety outputs (P-channel MOS FET).
  • Two auxiliary PNP transistor outputs for system status monitoring and diagnostics.
  • Configurable OFF-delay time up to 150 seconds.
  • Spring-cage terminal blocks (RC type) for fast wiring and high vibration resistance.
  • Solid-state outputs reduce wear and maintenance overhead compared to electromechanical relays.
  • Clear LED diagnostic indicators on the front panel for simplified troubleshooting.

Applications

  • Emergency stop circuit monitoring.
  • Safety light curtain and safety switch integration.
  • Controlled deceleration and delayed guard interlocking systems.
  • Robotic cell gate and access door monitoring.
  • Industrial machinery requiring phased shutdown sequences.

Technical Specifications

CategorySpecification ParameterValue
Manufacturer Omron Omron
Model / Part Number G9SX-ADA222-T150-RC G9SX-ADA222-T150-RC
Series G9SX Series G9SX Series
Module Type Flexible Safety Unit (Advanced Unit) Flexible Safety Unit (Advanced Unit)
Rated Supply Voltage 24 VDC 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage -15% to 10% of rated supply voltage
Power Consumption 4 W maximum 4 W maximum
Safety Inputs Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kOhms Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kOhms
Instantaneous Safety Outputs 2 outputs (P-channel MOS FET) 2 outputs (P-channel MOS FET)
OFF-Delayed Safety Outputs 2 outputs (P-channel MOS FET) 2 outputs (P-channel MOS FET)
Auxiliary Outputs 2 outputs (PNP transistor, 100 mA max.) 2 outputs (PNP transistor, 100 mA max.)
Maximum OFF-Delay Time 150 seconds 150 seconds
Safety Output Load Current 1 A DC max. (using 2 outputs or less), 0.8 A DC max. (using 3 outputs or more) 1 A DC max. (using 2 outputs or less), 0.8 A DC max. (using 3 outputs or more)
Terminal Block Type Spring-cage terminals Spring-cage terminals
Vibration Resistance Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Weight 0.2 kg 0.2 kg

Installation Guidelines

For safe and reliable installation, adhere to the following guidelines:

  • Mounting: Mount the unit inside an IP54 or higher rated control cabinet on a standard 35 mm DIN rail. Ensure there is sufficient clearance for ventilation around the heat dissipation vents.
  • Wiring: Use solid or stranded wires with the recommended strip length for the spring-cage terminals. No tightening torque is required, but ensure the wire is fully inserted and locked.
  • Power Supply: Connect a regulated 24 VDC power supply. The DC source must provide protective separation (SELV/PELV) to comply with safety standards.
  • Grounding: Connect the functional ground terminal securely to the system's ground bar to reduce electromagnetic interference.
Loading product navigation…

What is the function of the 'RC' suffix on the G9SX-ADA222-T150-RC?

The 'RC' suffix designates that the unit is equipped with spring-cage (tension clamp) terminal blocks, which offer quick, maintenance-free wiring and excellent resistance to mechanical vibration.

What is the maximum configurable OFF-delay time for this safety unit?

This module features a maximum OFF-delay time of 150 seconds (indicated by the T150 designation).

How do the output current ratings change based on the number of active safety outputs?

When using 2 safety outputs or less, the maximum load current is 1 A DC per output. When using 3 safety outputs or more, the maximum load current is reduced to 0.8 A DC per output.

What power supply is required for the G9SX-ADA222-T150-RC?

The unit operates on a rated supply voltage of 24 VDC, with an allowable operating range of 20.4 VDC to 26.4 VDC.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...