Omron S8VK-WA24024 S8VK-W Series Three-phase Input Power Supply

Omron S8VK-WA24024 S8VK-W Series Three-phase Input Power Supply

Apenas 6 item(ns) restante(s) em estoque
  • Fabricante: Omron

  • Nº do Produto: S8VK-WA24024

  • País de origem:Japão

  • Tipo de Produto: Three-phase Power Supplies

  • Pagamento: T/T, Western Union

  • Peso: 2000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver detalhes completos

Description

Operating as a high-efficiency electrical conversion module, the Omron S8VK-WA24024 delivers stable direct current to demanding industrial automation networks from a three-phase power source. This switch-mode power supply is engineered to mitigate phase unbalance risks and provide continuous, reliable 24 VDC output within compact control cabinets. Designed with a robust covered housing and integrating Omron's proprietary Push-In Plus terminal connection technology, the unit minimizes installation labor while maximizing resistance to physical vibrations common in heavy industrial manufacturing environments.

Features

  • Three-Phase Input: Supports input ranges from 200 to 240 VAC, reducing neutral current loading and balancing phases.
  • Push-In Plus Terminals: Enables rapid, tool-free wiring that maintains continuous tension to prevent terminal loosening under vibration.
  • Dynamic Current Boost: Delivers up to 15 A of maximum boost current to support high-inrush startup loads such as solenoids, motors, and capacitive circuits.
  • Space-Saving Footprint: Highly compact side-by-side mounting design optimizes DIN-rail space allocation.
  • IP20 Protection: Covered construction provides finger-safe operation and compliance with EN/IEC 60529 standards.

Applications

  • Automotive assembly machinery control panels
  • High-speed packaging and sorting systems
  • Semiconductor fabrication tool power distribution
  • Water and wastewater treatment processing equipment
  • General manufacturing plant PLC and sensor power networks

Technical Specifications

Specification Parameter Verified Engineering Value
Manufacturer Omron
Model Number S8VK-WA24024
Series Name S8VK-W
Rated Input Voltage 200 to 240 VAC (Three-Phase)
Power Rating 240 W
Rated Output Voltage 24 VDC
Rated Output Current 10 A
Maximum Boost Current 15 A
Terminal Type Push-In Plus Terminal Block
Construction Type Covered
Degree of Protection IP20 (EN/IEC 60529)
Unit Weight 0.8 kg
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal Block Section Terminal Designation Functional Assignment
Input Terminals (Top) L1 AC Input Phase 1
L2 AC Input Phase 2
L3 AC Input Phase 3
PE (Ground Symbol) Protective Earth Ground (Safety Ground)
Output Terminals (Bottom) +V (1) Positive 24 VDC Output Line 1
+V (2) Positive 24 VDC Output Line 2
-V (1) Negative 24 VDC Output Line 1 (Return)
-V (2) Negative 24 VDC Output Line 2 (Return)

Empirical Engineering Insights

Alternative Models & Compatibility

The S8VK-WA24024 serves as a more reliable alternative to single-phase S8VK-G or S8VK-X units when deployed in facilities suffering from persistent neutral line noise or phase unbalance. Because it derives power across three balanced phases, it prevents the local neutral circuit from overheating. When substituting this unit for older legacy switch-mode models, verify the 3-phase line configuration, as this module requires a nominal input of 200 to 240 VAC to meet the rated 240W threshold.

Application Pitfalls & Engineering Notes

A common mistake during panel integration is overloading the 15 A boost current duration. While the S8VK-WA24024 cleanly handles up to 150% of its rated capacity, this boost is strictly rated for temporary duty cycles. Continuous operation beyond the designated peak window will trigger thermal overcurrent protection, causing the output voltage to dip or cycle. Ensure the control cabinet maintains at least 15 mm of free spacing on both side panels and 50 mm vertically to allow optimal convection cooling, as restricted air passage accelerates thermal degradation.

Commissioning & Wiring Tips

To ensure gas-tight connections with the Push-In Plus mechanism, strip solid conductor wires or crimped ferrules to exactly 10 mm. When introducing stranded wires without ferrules, utilize a flathead precision screwdriver to depress the orange release tab prior to inserting the wire. Avoid twisting the stranded wires to prevent individual copper strands from splaying, which can lower the effective contact cross-section and generate localized hotspot resistance.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and secondary electrical systems before attempting installation, wiring, or physical inspection of the S8VK-WA24024. Confirm that the input line voltage matches the rated three-phase range (200 to 240 VAC) to prevent immediate terminal and internal capacitor damage.
1
Mount the power supply unit securely onto a standard 35mm DIN rail. Ensure the lock lever on the back of the chassis snaps firmly into place.
2
Wire the Protective Earth (PE) terminal first to a certified panel ground bus to establish appropriate EMI suppression and fault safety pathing.
3
Insert the three incoming phase wires (L1, L2, L3) into the top terminal block blocks, verifying that each wire is locked securely into position.
4
Connect the 24 VDC system load lines to the corresponding +V and -V output terminals located on the bottom block. Double-check polarity alignment before applying line voltage.
Loading product navigation…

What are the benefits of using a three-phase power supply like the S8VK-WA24024 over a single-phase model?

Using three-phase AC input eliminates neutral conductor currents, reduces input line current per phase, and significantly improves system reliability under load unbalance across the main facility distribution lines.

How long can the S8VK-WA24024 sustain its peak boost current of 15 A?

The maximum 15 A boost current is designed for transient startup loads and should only be sustained for a short duration, typically up to 5 seconds. Exceeding this limit triggers internal thermal protection mechanisms.

Are tools required to connect cables to the Push-In Plus terminal blocks?

No. Solid wires and stranded wires with crimped ferrules can be inserted directly without tools. Uncrimped stranded wires require depressing the integrated release tab with a small flathead screwdriver during insertion.

What are the minimum clearances required around the power supply inside the enclosure?

For natural air convection cooling, maintain a minimum clearance of 15 mm on both horizontal sides of the unit and 50 mm above and below the housing.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Japão

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...