1 de 1

ProSoft MVI69E-MBS CompactLogix Modbus Serial Enhanced Communication Module

ProSoft MVI69E-MBS CompactLogix Modbus Serial Enhanced Communication Module

Apenas 10 item(ns) restante(s) em estoque
  • Fabricante: ProSoft

  • Nº do Produto: MVI69E-MBS

  • País de origem:Estados Unidos

  • Tipo de Produto: Modbus Serial Enhanced Communication Modules

  • Pagamento: T/T, Western Union

  • Peso: 3000g

  • Porto de embarque: Xiamen

  • Garantia: 12 meses

Quantidade
Ver informações completas

Description

Designed to facilitate seamless serial communication within Rockwell Automation CompactLogix control platforms, the ProSoft MVI69E-MBS provides high-speed integration of Modbus RTU and ASCII protocol devices. By acting as a direct interface module on the 1769 backplane, this module enables CompactLogix processors to interface easily with up to two independent Modbus networks. The device functions as either a Modbus Master or Slave, utilizing user-defined memory mapping to transfer up to 240 words of register data per direction. Configuration is managed via the dedicated ProSoft Configuration Builder utility, allowing field engineers to define baud rates, parity, and data transfer offsets without writing complex ladder logic.

Key Features

  • Dual Isolated Serial Ports: Supports independent configuration for RS-232, RS-422, or RS-485 serial standards.
  • Flexible Memory Allocations: Adjustable input/output database size options of 60, 120, or 240 16-bit integers to match controller memory capacities.
  • Multi-Protocol Support: Integrates both Modbus RTU (binary with CRC-16) and Modbus ASCII (with LRC error checking) operation modes.
  • Onboard Diagnostics: Detailed error codes, network counters, and port status registers are mapped directly to controller tags.
  • Software-Selectable Addressing: Full software selection of master or slave node addresses ranging from 1 to 247.

Applications

  • Interfacing CompactLogix systems with Variable Frequency Drives (VFDs) and motor control centers (MCCs).
  • Connecting legacy flow computers, SCADA systems, and Human Machine Interfaces (HMIs).
  • Integrating multi-parameter power monitors, protection relays, and RTU devices on factory floors.
  • Distributed telemetry systems and remote municipal automation installations.

Technical Specifications

Parameter Specification
Manufacturer ProSoft Technology
Model Number MVI69E-MBS
Compatible Backplane Rockwell Automation 1769 CompactLogix
Backplane Current Draw 500 mA at 5 VDC
Serial Ports 2 x RJ45 (RS-232, RS-422, RS-485 configurable)
Baud Rate Range 110 bps to 115.2 kbps
Data Map Size Up to 240 16-bit read/write registers
Configuration Software ProSoft Configuration Builder (PCB)
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 85 degC
Shipping Weight (Calculated) 3.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The MVI69E-MBS serves as an upgraded alternative to the legacy MVI69-MCM module. While physical footprints are identical, the 'E' series utilizes Add-On Instructions (AOI) rather than traditional ladder-logic based block transfers. Existing legacy system conversions require updating the controller tag structures within Studio 5000 and downloading the latest .L5X files from ProSoft.

Application Pitfalls & Engineering Notes

Observe the 1769 power supply distance rating when planning system layouts. The module has a distance rating of 4, meaning it cannot be installed more than 4 slots away from the power supply module. Exceeding this distance limit will result in intermittent backplane communication failures and module startup issues.

Commissioning & Wiring Tips

Always utilize the provided RJ45-to-DB9 terminal adapters to guarantee pin alignment for RS-485 multi-drop topologies. If you are constructing custom RJ45 cables, maintain proper shielding practices and terminate long RS-485 runs with 120-ohm resistors across Rx/Tx terminals to mitigate signal reflections.

Installation Guidelines

CRITICAL WARNING: De-energize the CompactLogix backplane and all field device wiring before initiating installation or module removal. Inserting or removing the module while the system is under power (Hot Swapping) can damage the electronic components and cause unpredictable control state changes.
  1. 1
    Ensure the controller and power supply modules are securely fastened to the DIN rail prior to installation.
  2. 2
    Align the tongue-and-groove slots of the MVI69E-MBS with the adjacent module and slide the unit into place.
  3. 3
    Engage the upper and lower latch locks on the side panel to secure the backplane connection.
  4. 4
    Connect the serial interfaces utilizing the proper RJ45-to-DB9 cabling adapters, securing any necessary strain reliefs.
Loading product navigation…

Is the MVI69E-MBS backward compatible with the MVI69-MCM?

Yes, it replaces the older MVI69-MCM, but it requires different Add-On Instructions (AOI) and is configured using ProSoft Configuration Builder (PCB) rather than direct controller profiles.

What is the maximum power supply distance rating for this module?

The module has a distance rating of 4. It must be installed within 4 slots of the CompactLogix system power supply to prevent bus power dropouts.

Does this module support both RS-232 and RS-485 connections?

Yes. Each serial port is individually configurable for RS-232, RS-422, or RS-485 communication standards without the need for manual physical jumper adjustments.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reabastecimento e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crítico na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Desde o Manuseio Delicado até a Automação Pesada

As garras robóticas modernas estão evoluindo além das mandíbulas mecânicas tradicionais. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...

Retrospectiva: Como os Primeiros Motores Elétricos Mudaram a Mineração Subterrânea

De compressores CC acionados por corda a carrinhos de mina movidos a bateria, as operações de mineração iniciais marcaram um ponto de virada na eletrificação industrial. Este artigo explora como os...

Factory I/O: Uma Ferramenta Moderna de Simulação de CLP para Treinamento em Automação Industrial

Factory I/O está transformando a educação em CLP ao oferecer simulações industriais 3D imersivas para estudantes, engenheiros e equipes de manutenção. A plataforma reduz a distância entre a teoria e...