1 из 6

ABB CI867K01 3BSE043660R1 System 800xA Modbus TCP Interface

ABB CI867K01 3BSE043660R1 System 800xA Modbus TCP Interface

Остался только 5 товар(ы) на складе
  • Производитель: ABB

  • Номер продукта: 3BSE043660R1

  • Страна происхождения:Швеция

  • Тип продукта: Modbus TCP Interface Modules

  • Штрихкод: 85389091

  • Оплата: Т/Т, Western Union

  • Вес: 500г

  • Размеры: 127.5 x 186 x 59 mm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Facilitating seamless Ethernet-based industrial communications, the ABB CI867K01 3BSE043660R1 acts as a high-performance Modbus TCP interface kit within the System 800xA and AC 800M controller architecture. This communication package includes the CI867 communication module and the TP867 baseplate, enabling direct connectivity to field instruments, third-party PLCs, and SCADA control networks. Engineered for high-speed industrial telemetry, it functions natively as both a Modbus TCP Master and Slave, ensuring flexible and reliable data exchanges across modern automated systems.

Key Features

  • Dual-channel RJ45 Ethernet interfaces supporting 10/100 Mbps transmission speeds.
  • Includes the rugged TP867 baseplate for stable backplane mounting and reliable shielding.
  • Comprehensive protocol handling for Modbus TCP Master and Slave configurations.
  • Full integration with ABB Control Builder M configuration software.
  • Hot-swappable communication hardware for maximum system availability and reduced downtime.

Industrial Applications

  • Integration of intelligent electronic devices (IEDs) and power meters into central control networks.
  • Inter-controller communications between ABB AC 800M assemblies and third-party PLC architectures.
  • Distributed SCADA telemetry in water treatment, chemical processing, and power generation plants.

Technical Specifications

Manufacturer ABB
Model Number CI867K01
Product ID / SKU 3BSE043660R1
Module Type Modbus TCP Communication Interface
Physical Composition CI867 Module & TP867 Baseplate Assembly
Ethernet Ports 2x RJ45 (Ch1, Ch2)
Transmission Rate 10/100 Mbps (Auto-negotiation)
Connection Limit Up to 120 simultaneous TCP connections
Customs Tariff Number 85176200
Country of Origin Sweden
Net Weight 0.7 kg
Shipping Weight (Calculated) 0.95 kg
Dimensions (D x H x W) 127.5 x 186 x 59 mm

Connections and Interfaces

Interface Terminal Interface Type Functional Assignment
Ch1 RJ45 Connector Primary Ethernet Connection (Modbus TCP Network)
Ch2 RJ45 Connector Secondary Ethernet Connection / Network Redundancy Path
Backplane Connector TP867 Baseplate Interconnect 24 V DC Power Input and Internal System Bus Communication

Empirical Engineering Insights

Alternative Models & Compatibility

The CI867K01 package directly succeeds older Modbus solutions within System 800xA. It requires Control IT firmware version 5.1 or higher loaded onto the PM8xx controller for correct interface addressing. If you are retrofitting older systems using Control Software version 5.0 or earlier, firmware upgrades or compatibility configuration patches are mandatory to ensure that the AC 800M controller recognizes the dual-channel capability of the TP867 baseplate assembly.

Application Pitfalls & Engineering Notes

To prevent communication module lockups, avoid overloading the 120-connection threshold. When configuring master devices, group individual Modbus polling requests into unified, block-read transactions instead of continuous, discrete register queries. This minimizes packet rates and protects the module's microprocessor from thermal overhead inside enclosed unventilated panels.

Commissioning & Wiring Tips

Always use Shielded Twisted Pair (STP) Cat5e or Cat6 cabling to prevent Electromagnetic Interference (EMI) in high-voltage switchgear environments. Ground the cable shields strictly at the industrial patch panel end rather than the TP867 baseplate to suppress potential ground loops. Confirm that the default network routing tables in Control Builder match the physical local network gateway to bypass ARP resolution failure.

Installation Guidelines

CRITICAL WARNING:

De-energize all AC 800M backplane power lines and external communication devices prior to installing or removing the TP867 baseplate. Static discharge and raw voltage spikes can cause irreversible hardware damage to the communication bus components.

1

Mount the TP867 baseplate onto the grounded standard horizontal DIN rail until the plastic locking tab clicks firmly into place.

2

Align the slide connectors of the adjacent communication or CPU modules to bridge the backplane connection path.

3

Carefully insert the CI867 interface module into the slot of the TP867 baseplate, exerting even pressure until it sits flush.

4

Connect the shielded RJ45 cables to Port Ch1 and/or Ch2, route the cabling through the designated panel ducting, and power on the system for commissioning.

Loading product navigation…

Can the CI867K01 be configured as both a Modbus TCP Master and Slave simultaneously?

Yes, the CI867K01 module supports concurrent Modbus TCP Master and Slave operational modes across its independent Ethernet ports, configured via Control Builder M.

What is the maximum number of Ethernet connections supported by the CI867 communication interface?

The module supports up to 120 simultaneous TCP connections, which must be allocated properly between Master and Slave configurations to prevent transaction drops.

Does the CI867K01 communication module support hot-swapping (Hot Configuration in Run)?

Yes, when mounted on the TP867 baseplate within an active AC 800M system, the CI867 interface can be replaced under power without shutting down the controller.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Country of origin
Швеция

Недавно просмотренные товары

Технические знания

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...